VA 08 34 53-2009 SECURITY DOORS AND FRAMES.pdf
《VA 08 34 53-2009 SECURITY DOORS AND FRAMES.pdf》由会员分享,可在线阅读,更多相关《VA 08 34 53-2009 SECURITY DOORS AND FRAMES.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、12-09 08 34 53 - 1 SECTION 08 34 53 SECURITY DOORS AND FRAMES SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and insert additional items required by project and renumber paragraphs. Identify all frames by types
2、. Verify that drawings show the required doors and frames. See VA Physical Security Design Guide for security requirements Obtain blast resistance requirements from Physical Security Design Standards Definitions, a separate publication provided by the VA. PART I - GENERAL 1.1 DESCRIPTION A. The exte
3、nt of forced-entry resistant (FE) and ballistic resistant (BR) door assemblies required for the Project is indicated on Contract Drawings, and in Door/Frame/Hardware schedules, including construction, profiles, swing, sizes, hardware, accessories, devices, and locations. 1.2 RELATED WORK A. Refer to
4、 Division 3, CONCRETE. B. Refer to Division 4, MASONRY. C. Refer to Division 5, METALS for steel supports. D. Doors and frames not designated for special security performances: / Section 08 11 13, HOLLOW METAL DOORS AND FRAMES / / Section 08 14 00, WOOD DOORS /. E. Windows and frames of a forced ent
5、ry/ballistic resistant rated: Section 08 56 53, SECURITY WINDOWS F. Door Hardware: Section 08 71 00, DOOR HARDWARE. G. Glazing and ballistic rated glazing: Section 08 80 00, GLAZING. H. Package transfer boxes: Section 11 17 36, PACKAGE TRANSFER UNITS. I. Deal trays of a Forced Entry/Ballistic Resist
6、ant rating: Section 08 56, 59, SERVICE AND TELLER WINDOW UNITS. J. Guard Booths: Section 13 34 19, METAL BUILDING SYSTEMS. K. Card readers and biometric devices: Section 28 13 11, PHYSICAL ACCESS CONTROL SYSTEMS Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
7、m IHS-,-,-12-09 08 34 53 - 2 L. Intrusion alarm: Section 28 16 11, INTRUSION DETECTION SYSTEM 1.3 PERFORMANCE REQUIREMENTS A. General: Fabricate and install FE/BR door assemblies to achieve indicated levels of resistance. Extend resistance to include anchorages, interfaces with adjoining substrates,
8、 and hardware. Security attacks shall be unable to penetrate through closed/locked security door assemblies in manner described; it is recognized that such attacks may damage units beyond repair and reuse, requiring replacement of work by Government: 1. Fire-rated assemblies: Where indicated for fir
9、e resistance, provide flush steel doors-and-frame units; comply with NFPA 80, Standard for Fire Doors and Windows. Provide units that have been tested by recognized testing agency in accordance with NFPA No. 252 and ASTM E2074: 2. Forced-Entry (FE) resistant assemblies: Where door assembly is shown
10、or scheduled as FE, provide door manufacturers material and fabrication for panels, inserts, hardware, devices, and framing of units. Provide rated units where shown or scheduled: /a. No FE resistance rating. / /b. Provide resistance of 5 minutes for forced entry, using basic hand tools. / /c. Provi
11、de resistance of 15 minutes for forced entry, using basic hand tools. / 3. Ballistic Resistant (BR) assemblies: Where door assembly is shown or scheduled as BR, provide door manufacturers materials and fabrication for panel, inserts, and framing of unit. Provide rated units where shown or scheduled.
12、 /No BR resistance rating: / /a. UL 752 Level 3. / 1.4 SUBMITTALS A. General: For each security door assembly, submit the following in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. 1. Product data for each element of work, whether purchased from other manufacturers or pr
13、ovided as door Fabricators standard production. Include data substantiating that products comply with requirements of these specifications. 2. Manufacturers standard color chart. 3. Certificates: Letter from manufacturer indicating the products have been certified to meet the specified ratings. Prov
14、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-12-09 08 34 53 - 3 4. Shop drawings showing each dimensioned details of each door assembly, including performance rating, swing, hardware set, and adjacent construction. Provide drawings on B-size 11 in x 1
15、7 inch (300 mm x 430 mm) sheets. Show typical door exterior elevations at not less than inch = 1 foot (1:50) scale. After final modifications and corrections have been incorporated into the drawings, submit drawings as AutoCAD files with DWG extension. Show the following: a. Unit information: 1) Mod
16、el Number. 2) Ballistic resistant rating. 3) Marks (window no.). 4) Door/frame finish. 5) Door type. b. Elevation Drawings: 1) Rough opening. 2) Door opening. 3) Frame opening. 4) Vision opening. 5) Finished floor. 6) Sill condition. 7) Undercut for carpet. 8) Weather-stripping. 9) Reference numbers
17、 for primer and finish paint, including number of coats applies. 10) Door class rating: rated or non-rated. 11) Door and frame gauge thickness. c. Plan drawings: 1) Relate to elevation on drawing. 2) Identify “Attack” and “Protected” sides. 3) Identify door swing (i.e., RH, LH, RHRB, LHRB). 4) Provi
18、de key on drawings. 5) Indicate room space numbers taken from Contract Drawings. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-12-09 08 34 53 - 4 d. Details: Show section at not less than inch = 1 ft (1:20) scale of members indicating construction,
19、 size, and thickness of components, frame profile, location of conduit entry, threshold configuration, vision panel together with connections, fastenings, and means of separating dissimilar metals. e. Breakdown of Product Line Items: 1) If Manufacturer produces one contract line item as several part
20、s (door with transom and sidelights), they shall breakout items on drawings. Each item shall be a subdivision of that product line item number. 2) Installation instructions shall cite all anchorage components, including complete description of expansion anchor as well as installation criteria such a
21、s torque requirements, minimum embedment, and minimum edge distance, and shall include alert to installers to avoid cutting of rebar during concrete anchor installation. 1.5 QUALITY ASSURANCE A. Testing Laboratory Qualifications: For compliance with non-security performance requirements (such as fir
22、e ratings, resistance to deterioration from moisture, accessibility to persons with disabilities, or sound attenuation) on security door assemblies of this Section, use only those testing laboratories which have successfully demonstrated to Project Manager that they have experience and capabilities
23、needed to satisfactorily conduct required tests. B. Provide products that have been certified by Bureau of Diplomatic Security (DS) in accordance with DS/PSD SD-STD-01.01. 1.6 IDENTIFICATION SYSTEMS A. Identify each assembly to provide VA with ready reference to original manufacturer to facilitate r
24、eorders, replacement parts, service, resolution of complaints, and inventory. The label shall be typically embossed/printed metal plate or metallic foil with adhesive backing for permanent identification. Locate label so that it is readily visible and convenient for identification by Project Manager
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0834532009SECURITYDOORSANDFRAMESPDF