1、06-01-12 07 21 13 - 1 SECTION 07 21 13 THERMAL INSULATION MODIFICATION 06-01-12 UPDATE OF STANDARDS Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 07 21 13 - 2 SECTION 07 21 13 THERMAL INSULATION SPEC WRITER NOTE: Delete between /_/ if not
2、applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: A. This section specifies thermal and acoustical insulation for buildings. B. Acoustical insulation is identified by thickness and words “Acoust
3、ical Insulation“. 1.2 RELATED WORK A. Insulating concrete systems: / Section 03 52 00, LIGHTWEIGHT CONCRETE ROOF INSULATION /. B. Insulation for insulated wall panels: Section 07 40 00, ROOFING AND SIDING PANELS. C. Insulation in connection with roofing and waterproofing: Section 07 22 00, ROOF AND
4、DECK INSULATION. D. Insulation for prefabricated metal buildings: Section 13 34 19, METAL BUILDING SYSTEMS. E. Safing insulation: Section 07 84 00, FIRESTOPPING. F. Insulation for refrigerators and freezers: Section 11 41 21, WALK-IN COOLERS AND FREEZERS / Section 11 53 23, LABORATORY REFRIGERATORS
5、/ Section 11 78 13, MORTUARY REFRIGERATORS/. 1.3 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES . B. Manufacturers Literature and Data: 1. Insulation, each type used 2. Adhesive, each type used. 3. Tape C. Certificates: Stating the type, thickness
6、 and “R“ value (thermal resistance) of the insulation to be installed. 1.4 STORAGE AND HANDLING: A. Store insulation materials in weathertight enclosure. B. Protect insulation from damage from handling, weather and construction operations before, during, and after installation. Provided by IHSNot fo
7、r ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 07 21 13 - 3 1.5 APPLICABLE PUBLICATIONS: A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. B. Ameri
8、can Society for Testing and Materials (ASTM): C270-10 Mortar for Unit Masonry C516-08 Vermiculite Loose Fill Thermal Insulation C549-06 Perlite Loose Fill Insulation C552-07 Cellular Glass Thermal Insulation. C553-08 Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications
9、 C578-10 Rigid, Cellular Polystyrene Thermal Insulation C591-09 Unfaced Preformed Rigid Cellular Polyisocynurate Thermal Insulation C612-10 Mineral Fiber Block and Board Thermal Insulation C665-06 Mineral Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing C728-05
10、(R2010) Perlite Thermal Insulation Board C954-10 Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Base to Steel Studs From 0.033 (0.84 mm) inch to 0.112 inch (2.84 mm) in thickness C1002-07 . Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Produ
11、cts or Metal Plaster Bases to Wood Studs or Steel Studs D312-00(R2006) . Asphalt Used in Roofing E84-10 . Surface Burning Characteristics of Building Materials F1667-11 . Driven Fasteners: Nails, Spikes and Staples. SPEC WRITER NOTE: 1. Make material requirements agree with applicable requirements s
12、pecified in the referenced Applicable Publications applies to the project. 2. Determine “R“ value required, based on U value used for design by HVAC. Generally indicate “R“ value required for thermal insulation on drawings in lieu of thickness and specify only Provided by IHSNot for ResaleNo reprodu
13、ction or networking permitted without license from IHS-,-,-06-01-12 07 21 13 - 4 these insulations which will meet the “R“ value for thickness shown in space available. Allow options where possible. 3. Do not use cellular plastic insulation exposed to the interior. Separate the insulation from the i
14、nterior by at least a 15 minute fire separation. If no separation is provided, select cellular glass block insulation. PART 2 - PRODUCTS 2.1 INSULATION GENERAL: A. Where thermal resistance (“R“ value) is specified or shown for insulation, the thickness shown on the drawings is nominal. Use only insu
15、lation with actual thickness that is not less than that required to provide the thermal resistance specified. B. Where “R“ value is not specified for insulation, use the thickness shown on the drawings. C. Where more than one type of insulation is specified, the type of insulation for each use is op
16、tional, except use only one type of insulation in any particular area. D. Insulation Products shall comply with following minimum content standards for recovered materials: Material Type Percent by Weight Perlite composite board 23 percent post consumer recovered paper Polyisocyanurate/polyurethane
17、Rigid foam 9 percent recovered material Foam-in-place 5 percent recovered material Glass fiber reinforced 6 percent recovered material Phenolic rigid foam 5 percent recovered material Rock wool material 75 percent recovered material The minimum-content standards are based on the weight (not the volu
18、me) of the material in the insulating core only. 2.2 MASONRY CAVITY WALL INSULATION: A. Mineral Fiber Board: ASTM C612, Type II, faced with a vapor retarder having a perm rating of not more than 0.5. B. Polyurethane or Polyisocyanurate Board: ASTM C591, Type I, faced with a vapor retarder having a p
19、erm rating of not more than 0.5. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 07 21 13 - 5 C. Polystyrene Board: ASTM C578, Type X. D. Perlite Board: ASTM C728. E. Cellular Glass Block: ASTM C552, Type I or IV. 2.3 PERIMETER INSULATION IN
20、 CONTACT WITH SOIL: A. Polystyrene Board: ASTM C578, Type IV, V, VI, VII, or IX where covered by soil or concrete. B. Cellular Glass Block: ASTM C552, Type I or IV. 2.4 EXTERIOR FRAMING OR FURRING INSULATION: A. Batt or Blanket: Optional. B. Mineral Fiber: ASTM C665, Type II, Class C, Category I whe
21、re framing is faced with gypsum board. C. Mineral Fiber: ASTM C665, Type III, Class A where framing is not faced with gypsum board. 2.5 ACOUSTICAL INSULATION: A. Mineral Fiber boards: ASTM C553, Type II, flexible, or Type III, semirigid (4.5 pound nominal density). B. Mineral Fiber Batt or Blankets:
22、 ASTM C665. Maximum flame spread of 25 and smoke development of 450 when tested in accordance with ASTM E84. C. Thickness as shown; of widths and lengths to fit tight against framing. 2.6 SOUND DEADENING BOARD: A. Mineral Fiber Board: ASTM C612, Type IB, 13 mm (1/2 inch thick). B. Perlite Board: AST
23、M C728, 13 mm (1/2 inch thick). 2.7 RIGID INSULATION: A. On the inside face of exterior walls, spandrel beams, floors, bottom of slabs, and where shown. B. Mineral Fiber Board: ASTM C612, Type IB or 2. C. Perlite Board: ASTM C728. D. Cellular Glass Block: ASTM C552, Type I. 2.8 MASONRY FILL INSULATI
24、ON: A. Vermiculite Insulation: ASTM C516, Type II. B. Perlite Insulation: ASTM C549, Type IV. 2.9 FASTENERS: A. Staples or Nails: ASTM F1667, zinc-coated, size and type best suited for purpose. B. Screws: ASTM C954 or C1002, size and length best suited for purpose with washer not less than 50 mm (tw
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0721132012THERMALINSULATIONPDF