VA 04 05 13-2011 MASONRY MORTARING.pdf
《VA 04 05 13-2011 MASONRY MORTARING.pdf》由会员分享,可在线阅读,更多相关《VA 04 05 13-2011 MASONRY MORTARING.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、09-11 04 05 13- 1 SECTION 04 05 13 MASONRY MORTARING SPEC WRITER NOTE: Delete between / - / if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: Section specifies mortar materials and mixes.
2、 1.2 RELATED WORK: A. Mortar used in Section: 1. Section 03 45 00, PRECAST ARCHITECTURAL CONCRETE. 2. Section 04 05 16, MASONRY GROUTING. 3. Section 04 20 00, UNIT MASONRY. 4. Section 04 05 31, MASONRY TUCK POINTING. 5. Section 04 72 00, CAST STONE MASONRY. B. Mortar Color: Section 09 06 00, SCHEDUL
3、E FOR FINISHES. SPEC WRITER NOTE: Do not require testing on station level projects, or small alteration projects. Coordinate with Section 01 45 29, TESTING LABORATORY SERVICES. 1.3 TESTING LABORATORY-CONTRACTOR RETAINED A. Engage a commercial testing laboratory approved by Resident Engineer to perfo
4、rm tests specified below. B. Submit information regarding testing laboratorys facilities and qualifications of technical personnel to Resident Engineer. 1.4 TESTS A. Test mortar and materials specified. B. Certified test reports. C. Identify materials by type, brand name and manufacturer or by origi
5、n. D. Do not use materials until laboratory test reports are approved by Resident Engineer. E. After tests have been made and materials approved, do not change without additional test and approval of Resident Engineer. F. Testing: 1. Test materials proposed for use for compliance with specifications
6、 in accordance with test methods contained in referenced specifications and as follows: 2. Mortar: a. Test for compressive strength and water retention; ASTM C270. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 04 05 13- 2 b. Mortar compressiv
7、e strengths 28 days as follows: Type M: Minimum 17230 kPa (2500 psi) at 28 days. Type S: Minimum 12400 kPa (1800 psi) at 28 days. Type N: Minimum 5170 kPa (750 psi) at 28 days. 3. Cement: a. Test for water soluble alkali (nonstaining) when nonstaining cement is specified. b. Nonstaining cement shall
8、 contain not more than 0.03 percent water soluble alkali. 4. Sand: Test for deleterious substances, organic impurities, soundness and grading. /5. High Bond Mortar: Test for compressive strength, tensile strength, flexural strength, and brick bond strength. / /G. During progress of work, testing lab
9、oratory specified in Section 01 45 29, TESTING LABORATORY SERVICES, takes and tests samples as specified in that section. Testing procedures and test methods in ASTM C780. / 1.5 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Certificates: /1. T
10、esting laboratorys facilities and qualifications of its technical personnel. / 2. Indicating that following items meet specifications: a. Portland cement. b. Masonry cement. c. Mortar cement. d. Hydrated lime. e. Fine aggregate (sand). /g. Color admixture. C. Laboratory Test Reports: 1. Mortar, each
11、 type. 2. Admixtures. D. Manufacturers Literature and Data: 1. Cement, each kind. 2. Hydrated lime. 3. Admixtures. 4. Liquid acrylic resin. 1.6 PRODUCT DELIVERY, STORAGE AND HANDLING A. Deliver masonry materials in original sealed containers marked with name of manufacturer and identification of con
12、tents. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 04 05 13- 3 B. Store masonry materials under waterproof covers on planking clear of ground, and protect damage from handling, dirt, stain, water and wind. 1.7 APPLICABLE PUBLICATIONS A. Pub
13、lications listed below form a part of specification to extent referenced. Publications are referenced in text by basic designation only. B. American Society for Testing and Materials (ASTM): C40-04 . Organic Impurities in Fine Aggregates for Concrete C91-05 . Masonry Cement C109-08 Compressive Stren
14、gth of Hydraulic Cement Mortars (Using 2-in. or 50-MM Cube Specimens) C144-04 Aggregate for Masonry Mortar C150-09 Portland Cement C207-06 Hydrated Lime for Masonry Purposes C270-10 Mortar for Unit Masonry C307-03(R2008) . Tensile Strength of Chemical - Resistant Mortar, Grouts, and Monolithic Surfa
15、cing C321-00(R2005) . Bond Strength of Chemical-Resistant Mortars C348-08 Flexural Strength of Hydraulic Cement Mortars C595-10 Blended Hydraulic Cement C780-10 Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry C979-10 Pigments for Integrally Colored Concre
16、te C1329-05 . Mortar Cement PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 2.1 HYDRATED LIME ASTM C207, Type S. 2.2 AGGREGATE FOR MASONRY
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0405132011MASONRYMORTARINGPDF