1、07-11 03 41 33 - 1 SECTION 03 41 33 PRECAST STRUCTURAL PRETENSIONED CONCRETE SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: A. This section specifi
2、es precast prestressed concrete construction including design not shown, fabrication, erection, and other related items including bearing pads and anchorage. B. Precast prestressed concrete includes / single tees / double tees / hollow- core slabs / beams and spandrels / columns / I beams/box beams
3、/ tee/keystone joists / step units / ribbed wall panels /. 1.2 RELATED WORK: A. Materials testing and inspection during construction: Section 01 45 29, TESTING LABORATORY SERVICES. B. Concrete: Section 03 30 00, CAST-IN-PLACE CONCRETE. C. Sealants and Caulking: Section 07 92 00, JOINT SEALANTS. D. A
4、rchitectural Precast Concrete Panels: Section 03 45 00, PRECAST ARCHITECTURAL CONCRETE. E. Repair of abraded galvanized and painted surfaces: Section 09 91 00, PAINTING. 1.3 QUALITY ASSURANCE: A. Manufacturer Qualifications: Precast concrete manufacturing plant shall be certified by Prestressed Conc
5、rete Institute, Plant Certification Program, prior to start of production. B. In lieu of above qualification, contractor shall meet and pay for following requirements: 1. Retain an independent testing or consulting firm approved by Resident Engineer. 2. This firm shall inspect precast plant at two-w
6、eek intervals during production and issue a report, certified by a registered Professional Engineer verifying that materials, methods, products and quality control meet all requirements of specifications and drawings. When report indicates to the contrary, Resident Engineer may reject any or all pro
7、ducts produced during period of noncompliance with above requirements. C. Precast concrete work shall be performed by firms that have demonstrated capability, subject to approval, to produce and erect type of work specified. Provided by IHSNot for ResaleNo reproduction or networking permitted withou
8、t license from IHS-,-,-07-11 03 41 33 - 2 D. Precast concrete manufacturer shall have on staff or shall retain a qualified registered Professional Structural Engineer to certify precast concrete conforms in all aspects to requirements of ACI 318. E. Erector Qualifications: Regularly engaged for at l
9、east 5 years in erection of precast structural concrete similar to requirements of this project. F. Requirements of Regulatory Agencies: Local codes plus applicable specifications, standards and codes are a part of these specifications. 1.4 SUBMITTALS: A. Submit in accordance with Section 01 33 23,
10、SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Erection Drawings: a. Plans and/or elevations locating and defining material furnished by manufacturer. b. Sections and details showing connections, cast-in items and their relation to structure. c. Description of all loose, cast-in and
11、field hardware. d. Field installed anchor location drawings. e. Erection sequences and handling requirements. f. Dead, live and other applicable loads used in design. 2. Production drawings: a. Elevation view of each member. b. Sections and details to indicate quantities and position of reinforcing
12、steel, anchors, inserts, and essential embedded hardware. c. Lifting and erection inserts. d. Dimensions and finishes. e. Prestress for strand and concrete strengths. f. Estimated cambers. g. Method of transportation. C. Product Design Criteria: 1. Loadings for design: a. Initial handling and erecti
13、on stresses. b. Dead and live loads as specified on contract drawings. c. Other loads specified for member where they are applicable. d. Deflection of precast members shall be limited as follows: 1) Vertical Live Load - Span/360 2) Wind Load - 0.0025 x Floor to Floor Height e. Design shall provide f
14、or thermal movements of completed structure. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 03 41 33 - 3 2. Design calculations of products shall be performed by a registered Professional Engineer experienced in precast prestressed concrete de
15、sign. 3. Design shall be in accordance with applicable codes, ACI 318 and the PCI Design Handbook. 4. Details for waterproof joints between precast members. D. Mix Designs: Submit proposed concrete mix designs and appropriate test data as specified in Part 2 of this section. E. Permissible Design De
16、viations: 1. Design connections according to the conceptual details shown in the contract documents. 2. Design deviations will be permitted only after Resident Engineers written approval of manufacturers proposed design supported by complete design calculations and drawings. 3. Design deviations sha
17、ll provide an installation equivalent to basic intent without incurring additional cost to the Government. F. Test Reports: Concrete and other material. 1.5 PRODUCT DELIVERY, STORAGE AND HANDLING: A. Delivery and Handling: 1. Lift and support precast concrete members during manufacturing, stockpilin
18、g, transporting and erection operations only at lifting or supporting points, or both, as shown on contract and shop drawings, and with approved lifting devices. Lifting devices shall have a minimum safety factor of 4. Exterior lifting hardware shall have a minimum safety factor of 5. 2. Transportat
19、ion, site handling, and erection shall be performed with acceptable equipment and methods, and by qualified personnel. B. Storage: 1. Store all units off ground. 2. Place stored units so that identification marks are discernible. 3. Separate stacked members by battens across full width of each beari
20、ng point. 4. Stack so that lifting devices are accessible and undamaged. 5. Do not use upper members of stacked tier as storage area for shorter member or heavy equipment. 1.6 APPLICABLE PUBLICATIONS: A. Publications listed below form a part of this specification to extent referenced. Publications a
21、re referenced in text by basic designation only. B. American Society for Testing and Materials (ASTM): Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-07-11 03 41 33 - 4 A36/A36M-08 Standard Specifications for Carbon Structural Steel A82-07 . Standar
22、d Specifications for Steel Wire, Plain, for Concrete Reinforcement A123/A123M-09 Standard Specifications for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products A153/A153M-09 Standard Specifications for Zinc Coating (Hot-Dip) on Iron and Steel Hardware A185-07 Standard Specifications for S
23、teel Welded Wire, Fabric, Plain, for Concrete Reinforcement A307-10 Standard Specifications for Carbon Steel Bolts and Studs A325-10 Standard Specifications for Structural Bolts, Steel, Heat Treated A416/A416M-10 Standard Specifications for Steel Strand, Uncoated Seven-Wire for Prestressed Concrete
24、A615/A615M-09 Standard Specifications for Deformed and Plain Billet-Steel Bars for Concrete Reinforcement A706/A706M-09 Standard Specifications for Low-Allow Steel Deformed and Plain Bars for Concrete Reinforcement A767/A767M-09 Standard Specifications for Zinc-Coated (Galvanized) Steel Bars for Con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0341332011PRECASTSTRUCTURALPRETENSIONEDCONCRETEPDF

链接地址:http://www.mydoc123.com/p-1074679.html