UOP 958-1998 AMMONIA IN HYDROCARBONS.pdf
《UOP 958-1998 AMMONIA IN HYDROCARBONS.pdf》由会员分享,可在线阅读,更多相关《UOP 958-1998 AMMONIA IN HYDROCARBONS.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、AMMONIA IN HYDROCARBONSUOP Method 958-98SCOPEThis method is an extraction procedure that, when used in conjunction with UOP Method 959, allows thedetermination of ammonia in liquid hydrocarbon streams. Other nitrogen species, if present, are notdetected by this method. This procedure yields quantita
2、tive results and has been tested in the range ofapproximately 0.5 to 10 mass-ppm ammonia. Higher concentrations can be determined by dilution of theaqueous extract as noted in UOP Method 959, or by performing the extraction using a larger volume ofwater and/or a smaller sample size (preferred if the
3、 ammonia level can be estimated).OUTLINE OF METHODAmmonia is extracted from the hydrocarbon sample using water (see Note 1). The amount of ammoniumion present in the extract is determined using UOP Method 959, an ion chromatographic method. The resultfrom that determination is used to calculate the
4、ammonia in the original sample. Hydrocarbon solutionscontaining ammonia are unstable and have a tendency to lose ammonia with time (see Note 2). Therefore, itis necessary to perform the hydrocarbon extraction and run the UOP Method 959 analysis within the sameworking day. If the ion chromatographic
5、analysis can not be run immediately, the sample extracts must berefrigerated (see UOP Method 959).APPARATUSReferences to catalog numbers and suppliers are included as a convenience to the method user. Othersuppliers may be used.Funnel, separatory, 125-mL, Fisher Scientific, Cat. No. 10-436APipets, v
6、olumetric transfer, Class A, 20- and 50-mL, Fisher Scientific, Cat. Nos. 13-650-2N and 13-650-2S, respectivelyRefrigerator, laboratory, explosion proof, Fisher Scientific, Cat. No. 97-950-1IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TODETERMINE THE APPLICABILI
7、TY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH ANDSAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THISPROCEDURE IN THE MANNER PRESCRIBED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS(MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) F
8、OR ALL OF THE MATERIALS USED INTHIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTIONEQUIPMENT (PPE). COPYRIGHT 1998 UOP LLCALL RIGHTS RESERVEDUOP Methods are available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken PA 19428-2959,Uni
9、ted States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service atserviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE.2 of 4958-98Water purification system, Barnstead NANOpure II, three module, equipped with Pretreatment (D0835),Ultrapure (D0809
10、) and Organic Free (D0820) replacement cartridges, Fisher Scientific, Cat. Nos. 09-050-254, 09-034-104, 09-034-3 and 09-034-175K, respectivelyREAGENTS AND MATERIALSAll reagents shall conform to the specifications established by the Committee on Analytical Reagents ofthe American Chemical Society, wh
11、en such specifications are available, unless otherwise specified.References to water mean deionized and distilled water that is subsequently treated with a BarnsteadNANOpure II water purification system to produce ionically pure, 18 megohm-cm, organic-free, water.Vials and caps, for sample water ext
12、ract, Fisher Scientific, Cat No. 03-339-10H. Rinse the vials and capsfive times with water, allow to air dry and store with the caps on.PROCEDURESample ExtractionIf the ammonia concentration can be estimated, the sample volume can be decreased and/or the extractwater volume increased (from that call
13、ed for below) to minimize dilution of the extract required for the ionchromatographic (UOP Method 959) determination. The volumes used must be recorded for later use inCALCULATIONS.1. Obtain the density of the hydrocarbon sample by ASTM Method D 4052.2. Pipet 50 mL of the hydrocarbon sample into a 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP9581998AMMONIAINHYDROCARBONSPDF