1、MERCAPTAN TYPES IN KEROSINE BY NMRUOP 935-94SCOPEThis method is for determining primary, secondary and tertiary mercaptans (thiols) in kerosines up toseveral thousand mass-ppm, based on the procedure previously suggested by E. Rafii, et al. (1,2). The lowerlimit of detection by 119Sn H decoupled, re
2、focused Insensitive Nucleus Enhancement by PolarizationTransfer (INEPT) Nuclear Magnetic Resonance (NMR) spectroscopy without preconcentration is 40 mass-ppm per mercaptan type in the kerosine. Lower concentrations can be determined using a specifieddistillation procedure. The only known interferenc
3、es are thiophenols and branched alcohols, such asisopropyl and butyl alcohols (see NOTE). The method relies upon the quantitative preparation of soluble tri-n-butyl tin derivatives of all of the thiols present.OUTLINE OF PROCEDUREUOP Method 163 (3) is performed to determine the total mercaptan sulfu
4、r content of the kerosine sample.The mercaptans are derivatized by reaction with bis(tributyltin) oxide (TBTO) to form the correspondingorgano-sulfur-tributyltin compounds. If required, vacuum distillation is performed to concentrate themercaptan-derivatives to greater than 40 mass-ppm for each type
5、 in the kerosine bottoms. The derivatizedsample or concentrate is diluted 50/50 (vol/vol) in a perdeuterobenzene (C6D6)/chromium (III)acetylacetonate solution and analyzed by 119Sn NMR spectroscopy using a proton decoupled, refocusedINEPT procedure. The NMR areas assignable to each mercaptan type ar
6、e determined by a specifiedintegration procedure. The area fraction attributable to each type is then multiplied by the total mercaptansulfur in the sample to determine the concentration of primary, secondary and tertiary thiols.APPARATUSReferences to catalog numbers and suppliers are included as a
7、convenience to the method user. Othersuppliers may be used.Adapter, universal, with gas inlet and 24/40 standard taper joints, Fisher Scientific, Cat. No. K179750-2114Balance, readability 0.01-g, 1800-g capacityIT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TODET
8、ERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH ANDSAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THISPROCEDURE IN THE MANNER PRESCRIBED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS(MSDS) OR EXPERIMENTAL MATERIAL SAFETY
9、 DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED INTHIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTIONEQUIPMENT (PPE). COPYRIGHT 1994 UOP LLCALL RIGHTS RESERVEDUOP Methods are available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
10、cken PA 19428-2959,United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service atserviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE.2 of 16935-94Caps, NMR tube, pressure, Wilmad Glass, sized appropriately for the NMR tube (see PROCEDURE,
11、Instrument Specification)Clamps, 3-prong, utility, Fisher Scientific, Cat. No. 05-769Cylinder, graduated, 250-mL, Class A, Fisher Scientific, Cat. No. 08-557EDerivatization apparatus, Dean-Stark, 24/40 standard taper joints, Fisher Scientific, Cat. No. K535800-0000Flask, boiling, round bottom, 500-m
12、L, 24/40 standard taper joint, with thermometer well, FisherScientific, Cat. No. 10-069AFlask, volumetric, Class A, 10-mLHeating mantle, spherical, 500-mL flask size, with cord, Fisher Scientific, Cat. No. 11-472BHeat tape, 610- x 13-mm (2-feet x 1/2-inch), Fisher Scientific, Cat. No. 11-463-54ANucl
13、ear Magnetic Resonance Spectrometer, capable of time-averaged, proton decoupled, refocusedINEPT analysis of 119Sn. See PROCEDURE, Instrument Specification for additional information.Pipet, Mohr, Class B, 1-mLPipet, volumetric transfer, Class A, 5-mLPlug, vortex, glass, Wilmad Glass, sized appropriat
14、ely for NMR tube (see PROCEDURE, InstrumentSpecification)Pump, vacuum, mechanical, Fisher Scientific, Cat. No. 01-182Rotary Evaporator, with reflux condenser and oil bath, Fisher Scientific, Cat. No. 09-548-224Regulator, gas, for supply of nitrogen gas for derivatization, Fisher Scientific, Cat. No.
15、 10-574NRing stand, with rectangular base, 250- x 230-mm with 890-mm rod, Fisher Scientific, Cat. No. 14-679Stirrer, magnetic bar, 32-mm (1.25-inch), Teflon covered, egg-shaped, Fisher Scientific, Cat. No. 14-511-58AStirrer, motor, magnetic, 50/60 Hz, Fisher Scientific, Cat. No. 11-501-4STemperature
16、 controller, stepless, 120 V, 2 required, Fisher Scientific, Cat. No. 13-931-12Thermometer, mercury, 76-mm immersion, calibrated from -5 to 400C, Fisher Scientific, Cat. No. 15-166C3 of 16935-94Thermometer, mercury, 76-mm immersion, 10/30 standard taper, calibrated from -10 to 360C, FisherScientific
17、, Cat. No. 15-002FTrap, vacuum distillation, borosilicate glass, 50/50 standard taper joints, Fisher Scientific, Cat. No. 11-184-1ETube, NMR sample, reusable, Ultra or Royal Imperial Quality Class, Wilmad Glass, sized appropriatelyfor NMR spectrometer (see PROCEDURE, Instrument Specification)Tubing,
18、 vacuum, rubber, red, Fisher Scientific, Cat. No. 14-173DREAGENTS AND MATERIALSUnless otherwise specified, all reagents shall conform to the specifications established by the Committeeon Analytical Reagents of the American Chemical Society, when such specifications are available.References to catalo
19、g numbers and suppliers are included as a convenience to the method user. Othersuppliers may be used.Acetone, free of alcohols, Fisher Scientific, Cat. No. A929-11Bis(tributyltin) oxide, 96% purity, Aldrich, Cat. No. B5,338-3Chromium(III) acetylacetonate, 97% purity, Aldrich, Cat. No. 20-223-1Chromi
20、um(III) acetylacetonate solution, 0.1-M. Weigh 0.349 g chromium(III) acetylacetonate into a 10-mL volumetric flask. Dilute to volume with C6D6. Mix thoroughly to dissolve.Dry iceGrease, high vacuum, silicone, Fisher Scientific, Cat. No. 14-635-5DNitrogen, gas, 99.9% minimum, 2 ppm H2O, Matheson Gas
21、Products, Extra DryPerdeuterobenzene, benzene-d6, C6D6, 99.6 atom-%, Cambridge Isotope Laboratories, Cat. No. DLM-1Pump oil, vacuum, Fisher Scientific, Cat. No. 01-184-150ATetramethyltin, 99+% purity, Aldrich, Cat. No. 14,647.1Tetramethyltin solution, 0.084-M. Weigh 0.15 g tetramethyltin into a 10-m
22、L volumetric flask containingapproximately 5-mL C6D6. Dilute to volume with C6D6. Mix thoroughly.ThreadToluene, 99.8% minimum purity, Fisher Scientific, Cat. No. T291-44 of 16935-94PROCEDUREHandle all reagents in a fume hood using the appropriate safety equipment.Mercaptan Sulfur AnalysisA 50-g samp
23、le is required for analysis by UOP Method 163 to obtain the thiol-sulfur content (totalmercaptan value) of the sample. This value will be used to determine the amount of TBTO to use inPROCEDURE, Preparation of Sample, and in CALCULATIONS.Preparation of Sample1. Clean the 500-mL round bottom flask wi
24、th acetone, follow with a toluene rinse and dry with nitrogengas. If extensive concentration is anticipated, because one or more of the mercaptan types are below 40 mass-ppm, then it is desirable to concentrate more than 200 g of kerosine at a time. If so, then proportionallymore kerosine, toluene,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP9351994MERCAPTANTYPESINKEROSINEBYNMRPDF

链接地址:http://www.mydoc123.com/p-1074574.html