UOP 899-2004 TRACE HYDROCARBONS IN HYDROGEN HYDROCARBON GASES OR LPG BY GC.pdf
《UOP 899-2004 TRACE HYDROCARBONS IN HYDROGEN HYDROCARBON GASES OR LPG BY GC.pdf》由会员分享,可在线阅读,更多相关《UOP 899-2004 TRACE HYDROCARBONS IN HYDROGEN HYDROCARBON GASES OR LPG BY GC.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIBE
2、D HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1988, 1997, 2004 UOP LLC ALL RIGHTS RES
3、ERVED uop and UOP are trademarks and/or service marks of UOP LLC. Marks of other proprietors may appear incidentally in this method for purposes such as product or service identification, but no claim is made to any other proprietors mark used. UOP Methods are available through ASTM International, 1
4、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 194428-2959, United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE. TRACE HYDROCARBONS IN HYDROGEN, HYDROCARBON GASES, O
5、R LPG BY GC uop Method 899-04 SCOPE This method is for determining individual trace C5minus hydrocarbon impurities in hydrogen or liquefied petroleum gas (LPG), where the specific trace components are sufficiently resolved from the major components, typically propane/propylene or ethane/ethylene. Co
6、mponents eluting after ethyl acetylene are grouped and reported as heavies. The range of quantitation for each component is 2 to 3000 mol- (or mass-) ppm; however, the lower limit of quantitation increases when major components interfere with the resolution of the impurities. REFERENCES ASTM Practic
7、e D 1265, “Sampling Liquefied Petroleum (LP) Gases (Manual Method),” www.astm.org ASTM Practice D 5287, “Automatic Sampling of Gaseous Fuels,” www.astm.org Scanlon, J. T. and Willis, D. E., Journal of Chromatographic Science, 23, 333-340 (1985) UOP Method 516, “Sampling and Handling of Gasolines, Di
8、stillate Fuels, and C3-C4Fractions,” www.astm.org UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org OUTLINE OF METHOD A reproducible volume of gas sample is injected into a gas chromatograph equipped with an alumina PLOT (porous layer open tubular) capillary column, a capillary inj
9、ection port, a flame ionization detector (FID), and a gas or LPG sampling valve. An LPG sample may be expanded and analyzed as a vapor, or analyzed directly in the liquid phase (see NOTE). The concentrations of the hydrocarbon impurities are determined by the external standard method of quantitation
10、, wherein peak areas are compared to the area of a calibration blend containing a known concentration of isobutane. For 2 of 17 899-04 For samples containing C5olefins, a second analysis, under a different column temperature program, is necessary to resolve methyl acetylene from an interfering C5ole
11、fin. APPARATUS References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used except as noted. Chromatographic column, 50 m of 0.53-mm ID PLOT fused silica capillary, internally coated to a film thickness of 9-m with alumina (GS-Alumina), J&
12、W Scientific, Cat. No. 115-3552. Columns from other suppliers, commonly called Al2O3/Na2SO4, provide similar separation but may not be quantitative for diolefins and acetylenes, and their use is not recommended when analysis of these components is necessary. Gas chromatograph, capable of temperature
13、 ramping, equipped with electronic pressure control, built for capillary column chromatography utilizing a split injection system, having a glass injection port insert, a heated valve box, and an FID that will give a minimum peak height response of 5 times the background noise for 2 mol-ppm of isobu
14、tane when operated at the recommended conditions, Agilent Technologies, Model 6890 Injection apparatus, gas, for injection of gas or expanded LPG samples, see Figure 1: Fitting, internal union, for connecting injection port to 6-port sampling valve, Valco Instruments, Cat. No. ZU1T Valve, 6-port, st
15、ainless steel, 1.59-mm (0.0625-inch) fittings, manual with standoff, Valco Instruments, Cat. No. C6UWE Sample loop, stainless steel, 100-L, Valco Instruments, Cat. No. SL100CUW Tubing, stainless steel, 1.6-mm (1/16-inch) OD, 0.76-mm (0.30-inch) ID, Alltech Associates, Cat. No. 300010 Injection appar
16、atus, LPG, for injection of LPG samples in the liquid phase, see Figure 2: Fitting, CGA, for blend cylinder, CGA No. 510, Matheson Gas Products Fitting, internal union, for connecting injection port to 4-port sampling valve, Valco Instruments, Cat. No. ZU1T Fitting, reducing union, 3.2-mm (1/8-inch)
17、 to 1.6-mm (1/16-inch), Swagelok, Cat. No. SS-200-6-1 Tubing, stainless steel, 1.6-mm (1/16-inch) OD, 0.76-mm (0.30-inch) ID, Alltech Associates, Cat. No. 300010 Tubing, translucent, FEP Teflon, 3.2-mm (1/8-inch) OD, 1.6-mm (0.062-inch) ID, 3450 kPa (500 psig), Alltech Associates, Cat. No. 45740 Val
18、ve, 4-port, stainless steel, 0.5-l internal sample volume, 1.59-mm (0.0625-inch) fittings, manual with standoff, Valco Instruments, Cat. No. CI4UWE.5 Valve, vent shut-off, Swagelok, Cat. No. SS-ORS2 3 of 17 899-04 Integrator, or data system, electronic, for obtaining peak areas. This device must int
19、egrate areas at a sufficiently fast rate so that the narrow peaks typically resulting from use of a capillary column can be accurately measured. ChemStation, Agilent Technologies. LPG expansion apparatus, for quantitative expansion of LPG from a liquid to a gas phase, see Figure 3: Fitting, male con
20、nector, stainless steel, 0.25-inch tube fitting to 0.25-inch male NPT, Swagelok, Cat. No. SS-400-1-4. Sample cylinders having an outlet fitting other than 0.25-inch female NPT will require a different fitting. Fitting, port connector, stainless steel, 0.25-inch tube fitting, Swagelok, Cat. No. SS-40
21、1-PC, 2 required Fitting, union tee, stainless steel, 0.25-inch, Swagelok, Cat. No. 400-3 Tubing, stainless steel, Type 304, 0.25-inch OD x 0.210-inch ID, Alltech Associates, Cat. No. 30301 Vacuum pump, capable of achieving a vacuum of 0.1-mm Hg, Fisher Scientific, Cat. No. 01-115-2 Valve, stainless
22、 steel, 0.25-inch, Swagelok, Cat. No. SS-1RS4 LPG expansion cylinder, sample cylinder for containing expanded LPG sample: Cylinder, 4- x 6-inch, 316 stainless steel, 1380 kPa (200 psi) internal pressure, double connection, 0.25-inch pipe hex bored through, Arthur Harris, Cat. No. B-270 Fitting, hex
23、nipple, stainless steel, 0.25-inch NPT, Swagelok, Cat. No. SS-4-HN, 3 required Fitting, tee, stainless steel, 0.25-inch NPT, Swagelok, Cat. No. SS-4-T Gauge, stainless steel, vacuum-pressure, -100 to +200 kPa gauge (-15 to +30.0 psig) range, Matheson Gas Products, Cat. No. 63-2204 Valve, stainless s
24、teel, 0.25-inch NPT inlet, 0.25-inch tube fitting outlet, Whitey, Swagelok, Cat. No. SS-1RM4-S4, 2 required Regulator, air, two-stage, high purity, delivery pressure range up to 690 kPa (100 psi), Matheson Gas Products, Model 3122-590 Regulator, helium, two-stage, high purity, delivery pressure rang
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP8992004TRACEHYDROCARBONSINHYDROGENHYDROCARBONGASESORLPGBYGCPDF

链接地址:http://www.mydoc123.com/p-1074560.html