UOP 826-2010 Carbon Dioxide in Amine Solution.pdf
《UOP 826-2010 Carbon Dioxide in Amine Solution.pdf》由会员分享,可在线阅读,更多相关《UOP 826-2010 Carbon Dioxide in Amine Solution.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1981, 2010 UOP LLC. All rights reserve
3、d. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.83
4、2.9585 PHONE. Carbon Dioxide in Amine Solution UOP Method 826-10 Scope This method is for determining carbon dioxide in amine solution using a commercially available total inorganic carbon analyzer. The lower limit of quantitation is 20 mg/L. References ASTM Method D513, “Total and Dissolved Carbon
5、Dioxide in Water,” www.astm.org ASTM Method D1293, “pH of Water,” www.astm.org UIC Application Note 9, “Determination of Carbon Dioxide in Amine Gas Scrubbing Solutions,” UIC Total Inorganic Carbon Analyzer Instrument Manual, Outline of Method The analyzer is purged of atmospheric CO2 and an aliqu
6、ot of the sample is injected. Acid is added to evolve the CO2 and the evolved gas is scrubbed to remove potentially interfering gases. The CO2 is then measured using coulometric titration. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other s
7、uppliers may be used. However, at this writing, UIC is the only known manufacturer of the apparatus required for this analysis. Balance, analytical, readable to 0.0001 g Balance, laboratory, readability 0.01-g Bottle, 500-mL, clear glass, with poly-lined cap, VWR, Cat. No. 89043-070, if needed, see
8、Procedure pH meter, conforming to the requirements given in ASTM Method D1293, “pH of Water” Scrubber, 500-mL, Ace Glass, Cat. No. 4055-06, if needed, see Procedure Syringe, 250-L, glass, cemented needle, VWR, Cat. No. 60373-061 or 60375-263 2 of 3 826-10 Total inorganic carbon analyzer, UIC, Model
9、CM140, with CM5015 coulometer; includes CM5014 analyzer and CM5130 acidification module. Contact the manufacturer for options, accessories, spare parts, and supplies necessary for the specific installation. The following options and supplies are listed in Application Note 9: Auxiliary scrubber assem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP8262010CARBONDIOXIDEINAMINESOLUTIONPDF