UOP 799-2008 Chloride in Liquid Hydrocarbons by Dry Colorimetry.pdf
《UOP 799-2008 Chloride in Liquid Hydrocarbons by Dry Colorimetry.pdf》由会员分享,可在线阅读,更多相关《UOP 799-2008 Chloride in Liquid Hydrocarbons by Dry Colorimetry.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 2008 UOP LLC. All rights reserved. Non
3、confidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.832.9585
4、 PHONE. Chloride in Liquid Hydrocarbons by Dry Colorimetry UOP Method 799-08 Scope This method is for determining the sum of organic chloride and hydrogen chloride (HCl) in liquid hydrocarbons at concentrations ranging from approximately 0.5 to 500 mass/volume-ppm (mg/L). Other halogens, if present,
5、 are determined as chloride. References ASTM Method D 4052, “Density and Relative Density of Liquids by Digital Density Meter,” www.astm.org ASTM Method D 4307, “Preparation of Liquid Blends for Use as Analytical Standards,” www.astm.org Instrument instruction manual, C.I.Analytics PN 2010-Cl-man UO
6、P Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method A commercial chloride analyzer utilizing dry colorimetric detection is set up according to the manufacturers specifications. The sample is subjected to pyrolysis which converts the organic chlorides to HCl. The pyrol
7、ysis product is then passed to a detector where the HCl causes a color change on sensitized paper. The measured color change is proportional to the quantity of chloride in the sample. Calibration is performed using blends of known concentrations of chloride in a liquid hydrocarbon. Apparatus Referen
8、ces to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Chloride analyzer, with Dry Colorimetric Detector (DCD), C.I.Analytics, 2010L. Stock replacement parts as recommended by the manufacturer. Regulator, air, two-stage, high purity, with
9、stainless steel diaphragm, delivery pressure range 30-700 kPa (4-100 psi), Matheson Tri-Gas, Cat. No. 3122-590 2 of 4 799-08 Regulator, nitrogen, two-stage, high purity, with stainless steel diaphragm, delivery pressure range 30-700 kPa (4-100 psi), Matheson Tri-Gas, Cat. No. 3122-580 Regulator, oxy
10、gen, two-stage, high purity, with stainless steel diaphragm, delivery pressure range 30-700 kPa (4-100 psi), Matheson Tri-Gas, Cat. No. 3122-540 Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Air, comp
11、ressed gas, 99.99% minimum purity Chlorobenzene, 99.9% minimum purity, Burdick if the isooctane is not halogen-free, find another source for the isooctane. Calculate the chloride concentration to three significant figures in each of the Calibration Blends using Equation 1. 3 of 4 799-08 6.112A5.35C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP7992008CHLORIDEINLIQUIDHYDROCARBONSBYDRYCOLORIMETRYPDF

链接地址:http://www.mydoc123.com/p-1074545.html