1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1977, 1992, 2008 UOP LLC. All rights r
3、eserved. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or
4、610.832.9585 PHONE. Chloride in Petroleum Distillates by Microcoulometry UOP Method 779-08 Scope This method is for determining chloride in liquid hydrocarbons at concentrations ranging from approximately 0.3 to 1000 ppm. Higher concentrations can be determined with appropriate sample dilution. The
5、method determines the total organic chloride. Some inorganic chloride present as salts is not included (see Note 1). Except for fluoride, other halogens that may be present in the sample are determined as chloride. Both nitrogen and sulfur compounds interfere at concentrations greater than approxima
6、tely 0.1%. Reference ASTM Method D 4052, Density and Relative Density of Liquids by Digital Density Meter, www.astm.org UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method A commercial microcoulometer is set up and calibrated with liquid standards. Two modes of samp
7、le introduction are permitted, direct injection into the combustion tube or boat inlet. Using the direct injection technique, the sample is injected at a controlled rate into the combustion tube. Using the boat inlet technique, a measured volume of sample is injected, either manually or with an auto
8、sampler, into an argon purged quartz boat. After the volatile components of the sample have evolved, the boat is moved into a heated zone of the pyrolysis tube, which contains oxygen blended with argon. The combustion products are sparged through a sulfuric acid dryer and into a cell where the halog
9、ens are automatically titrated to a coulometric endpoint. The number of halide equivalents are calculated automatically (as chloride ions) and then reported in the concentration units selected. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Ot
10、her suppliers may be used. Balance, readability 0.1-mg 2 of 9 779-08 Beakers, borosilicate glass, 50-, 100-, and 250-mL, Fisher Scientific, Cat. Nos. 02-539-G, -H, and -K, respectively Bottles, washing, low density polyethylene, 125-, 250- and 500-mL, Fisher Scientific, Cat. Nos. 03-409-10AA, -10BB
11、and -10CC, respectively Flasks, volumetric, Class A, borosilicate glass, 25-, 50-, 100-, 250- and 1000-mL, Fisher Scientific, Cat. Nos. 10-210-8A, -8B, -8C, -8E and -8G, respectively Flowmeter, digital, gas, operating range 0.5 to 500 mL/min, Fisher Scientific, Cat. No. 11-164-45 Microcoulometer, wi
12、th attached furnace, cell, autosampler, controls and computer, Model TCL-100, Dia Instruments Co., Ltd., available from COSA Instrument. Microcoulometers from other manufacturers such as Thermo ECS-3000, Analytik Jena Multi EA 3100, or Dohrmann MCTS-120 (no longer manufactured), are also available,
13、but have not been tested. Follow the manufacturers recommendations for maintaining a supply of spare parts and consumables. Pipet filler, Fisher Scientific, Cat. No. 13-681-102A Pipet, transfer, disposable plastic, 152-mm length, Fisher Scientific, Cat. No. 13-711-5A Pipet, volumetric, Class A, 2-,
14、5- and 10-mL, Fisher Scientific, Cat. No. 13-650-2C, -2F and -2L, respectively Refrigerator, flammable storage or explosion proof, Fisher Scientific, Cat. Nos. 97-938-1 or 97-950-1 Regulator, argon, single-stage, with stainless steel diaphragm, Matheson Gas Products, Cat. No. 3231. This regulator is
15、 installed downstream of the two-stage regulator to provide better flow control. Regulator, argon, two-stage, with stainless steel diaphragm, Matheson Gas Products, Cat. No. 3104-580 Regulator, oxygen, single-stage, with stainless steel diaphragm, Matheson Gas Products, Cat. No. 3231. This regulator
16、 is installed downstream of the two-stage regulator to provide better flow control. Regulator, oxygen, two-stage, with stainless steel diaphragm, Matheson Gas Products, Cat. No. 3104-540 Syringes, liquid, 10-, 25-, 50- and 100-L, Hamilton 1700 Series, Alltech, Cat. Nos. 80000, 80200, 80900 and 81000
17、, respectively (if an autosampler is not used) Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. References to water mean deionized or distilled water. The following items are required to perform the anal
18、ysis. Additional reagents and materials may be required depending on the specific microcoulometer utilized. Where different reagents are specified in the instrument manual, follow the manufacturer recommendations. Acetic acid, glacial, Fisher Scientific, Cat. No. A38 Ammonium hydroxide, concentrated
19、, Fisher Scientific, Cat. No. A669 Argon, compressed gas, 99.99% minimum purity. 3 of 9 779-08 Chlorobenzene, CHROMASOLV 99.9% minimum purity, Aldrich Chemical, Cat. No. 270644-100ML 1-Chlorobutane, CHROMASOLV 99.8% purity, Aldrich Chemical, Cat. No. 34958-100ML Inorganic chloride standard (NaCl or
20、HCl Solution), as recommended by the microcoulometer manufacturer Oxygen, compressed gas, 99.98% minimum purity Quartz wool, high purity, Alltech Associates, Cat. No. 4033 Sodium bicarbonate, Aldrich Chemical, Cat. No. 34,094-4 Sulfuric acid, concentrated, Aldrich Chemical, Cat. No. 32,050-1 Isoocta
21、ne (2,2,4-Trimethylpentane), chloride free, Mallinckrodt Baker, Cat. No. 9335. Verify that the isooctane is chloride free by analysis on the microcoulometer. Procedure The analyst is expected to be familiar with general laboratory practices, with the technique of microcoulometry, and with the equipm
22、ent being used. This procedure is written for the Dia Instruments microcoulometer listed in Apparatus. If a different microcoulometer is used, modify the procedure as needed. Preparation of Standards 1-Chlorobutane or chlorobenzene, diluted in isooctane is used in this procedure as an example of how
23、 a standard solution is made. Other standards, such as 2,4,5-trichlorophenol in HPLC grade methanol, may be used provided that the solvent is chloride free and that equivalent results can be obtained as from the chlorobenzene. For a 1-chlorobutane standard, prepare a nominally 10,000-g Cl/mL stock s
24、olution as follows: 1. Weigh approximately 2.611 g of 1-chlorobutane to the nearest 0.1 mg into a tared, 100-mL volumetric flask that is chloride free. 2. Dilute to the mark with isooctane Store the stock solution in the volumetric flask in a refrigerator. When stored in a refrigerator, the stock so
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP7792008CHLORIDEINPETROLEUMDISTILLATESBYMICROCOULOMETRYPDF

链接地址:http://www.mydoc123.com/p-1074538.html