UOP 326-2008 DIENE VALUE BY MALEIC ANHYDRIDE ADDITION REACTION.pdf
《UOP 326-2008 DIENE VALUE BY MALEIC ANHYDRIDE ADDITION REACTION.pdf》由会员分享,可在线阅读,更多相关《UOP 326-2008 DIENE VALUE BY MALEIC ANHYDRIDE ADDITION REACTION.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1965, 1982, 2007, 2008 UOP LLC. All ri
3、ghts reserved. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832
4、.9555 FAX, or 610.832.9585 PHONE. Diene Value by Maleic Anhydride Addition Reaction UOP Method 326-08 Scope This method is for determining maleic anhydride reactivity with a wide variety of oils, ranging from debutanized light hydrocarbon distillates to heavy drying oils, using titration. The method
5、 gives a measure of the conjugated diolefin content of the sample. The determination is somewhat empiricalsince some conjugated diolefins may not react completely, while certain compounds other than conjugated diolefins also may be reactive. For example, anthracene, along with many of its homologs a
6、nd corresponding alkylated compounds, as well as certain vinyl aromatics, react as dienes with maleic anhydride. Therefore, the results obtained by this method must be carefully interpreted in the light of these specified limitations. The range of quantitation for diene value is from 1.2 to over 100
7、. A modified procedure can be used to estimate diene values less than 1.2. If the average molecular weight of the conjugated diolefins is known or can be estimated, the mass-% concentration of conjugated diolefins can be calculated. References AOCS Official Method Th 1a-64, “Diene Value,” www.aocs.o
8、rg Ellis, B. A. and Jones, R. A., Analyst 61, 812 (1936) McKinney, R. S., Hallbrook, N. J., and Rose, W. G., Oil and Soap 19, 141-143 (1942) Norton, J. A., Chem. Rev. 31, 319 (1942) UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method Maleic anhydride is refluxed wit
9、h the sample in boiling toluene for 3 hours. The unreacted maleic anhydride is hydrolyzed to maleic acid, extracted from the reaction mixture, and titrated with sodium hydroxide. A blank is run using the same amount of maleic anhydride as charged to the reaction flask. The amount reported as having
10、reacted with the sample is the net volume obtained by potentiometric titration difference, and from this data the diene value and/or the percent dienes can be calculated. An alternative titration technique, using a manual (colorimetric) procedure, is described in the Appendix. Additional information
11、 regarding this technique is provided in References. 2 of 10 326-08 Definition Diene value, the number of grams of iodine equivalent to the amount of maleic anhydride that reacts with 100 g of sample (on the basis of 2 atoms of iodine per mole of maleic anhydride) under the specified reaction condit
12、ions. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Balance, readability 0.01-g Beaker, 250-mL, tall, without spout, borosilicate glass, Reliance Glass, Cat. No. G-9906-002 or Brinkmann, Cat. No. 020212128, three
13、required Bottle, polyethylene, 1000-mL, Fisher Scientific Co., Cat. No. 03-313-5D Condenser, Liebig, with Ts 24/40 ground-glass joint, Fisher Scientific, Cat. No. 07-721C, at least two required Crucible, high form, 10-mL, porcelain, Fisher Scientific, Cat. No. 07-965C, with cover, Fisher Scientific,
14、 Cat. No. 07-970D Cylinders, graduated, 10- and 25-mL, Class B, Fisher Scientific, Cat. Nos. 08-549-5B and -5C, respectively Desiccator, 160-mm ID, and porcelain plate, Fisher Scientific, Cat. Nos. 08-632 and 08-641A, respectively Electrode, combination glass, with sleeve diaphragm, double junction,
15、 Brinkmann Instruments, Cat. No. 20 91 050-0. Store in water when not in use. Flask, Erlenmeyer, 250-mL, Fisher Scientific Co., Cat. No. 10-040F Flask, Erlenmeyer, 250-mL, with Ts 24/40 ground-glass joint, Fisher Scientific, Cat. No. 10-047C, at least two required Flask, Erlenmeyer, 500-mL, borosili
16、cate glass, heavy walled, with side arm, Fisher Scientific, Cat. No. 10-180K, optional, see Standardization of Sodium Hydroxide Flask, volumetric, 1000-mL, Class A, Fisher Scientific, Cat. No. 10-210-5G Funnel, filter, Fisher Scientific, Cat. No. 10-326-2C Funnel, separatory, 250-mL, Fisher Scientif
17、ic, Cat. No. 10-437-5C Hot plate, Thomas Scientific, Cat. No. 5983C06 Magnetic stir bar, Fisher Scientific, Cat. No. 14-511-64, three required Mortar, porcelain, 130-mm OD, with pestle, porcelain, Fisher Scientific, Cat. Nos. 12-961-C and 12-961-5C, respectively Oven, drying, capable of operation at
18、 120C, Fisher Scientific, Cat. No. 13-246-506G Pipet filler, Fisher Scientific, Cat. No. 13-681-102A Pipet, Mohr, 25-mL, Fisher Scientific, Cat. Nos. 13-665-100F Pipets, volumetric transfer, 2-, 3-, 5-, 10-, and 20-mL, Class A, Fisher Scientific, Cat. Nos. 13-650-2C, -2D, -2F, -2L, and -2N, respecti
19、vely 3 of 10 326-08 Regulator, nitrogen, two-stage, high purity, delivery pressure range 15-200 kPa (2-30psig), Matheson Gas Products, Model 3121-580 Ring stands and clamps, to hold apparatus Stirrer, magnetic, Fisher Scientific, Cat. No. 14-493-120S Stirring rod, glass, Fisher Scientific, Cat. No.
20、11-380D Titrator, potentiometric, recording, 2000-mV range, 1-mV resolution, capable of reducing the titration rate to a minimum in the vicinity of the endpoint, with dispenser having a volume readout of 0.00 - 99.99 mL, 0.0001 of the buret volume resolution, Metrohm Model 836 Titrando system with o
21、ptional sample changer, and 20-mL buret with a reservoir guard tube, Brinkmann Instruments Tongs, stainless steel, crucible, Fisher Scientific, Cat. No. 15-186 Tubing, thick walled, rubber, for vacuum use, Fisher Scientific, Cat. No. 14-173D, optional, see Standardization of Sodium Hydroxide Vacuum
22、pump, Precision Model No. DD-20, Fisher Scientific, Cat. No. 01-182, optional, see Standardization of Sodium Hydroxide Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. References to water mean deionized
23、water. Absorbent, carbon dioxide, Ascarite II, 20 to 30-mesh, Fisher Scientific, Cat. No. A184-500 Boiling chips, silicon carbide, Thomas Scientific, Cat. No. 1590D33 Desiccant, 8-mesh, indicating, Fisher Scientific, Cat. No. 07-578-3A Electrolyte, 3 mol/L potassium chloride, Brinkmann, Cat. No. 20
24、09 610-1 Filter paper, qualitative, medium, acid-free, non acid-washed, Whatman No. 1, Fisher Scientific, Cat. No. 09-805F Maleic anhydride 108-31-6, 99%, mp 52-55C, Acros Organics, Cat. No. 36494, Fisher Scientific Maleic anhydride in toluene. Dissolve 60 g of maleic anhydride in warm toluene. Cool
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP3262008DIENEVALUEBYMALEICANHYDRIDEADDITIONREACTIONPDF

链接地址:http://www.mydoc123.com/p-1074484.html