UL SUBJECT 984A-2001 Outline of Investigation for Compatibility of Insulating Materials and Refrigerant Oil for Use in Hermetic Refrigerant Motor-Compressors (Issue 2)《用于密封制冷电机压缩机的.pdf
《UL SUBJECT 984A-2001 Outline of Investigation for Compatibility of Insulating Materials and Refrigerant Oil for Use in Hermetic Refrigerant Motor-Compressors (Issue 2)《用于密封制冷电机压缩机的.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 984A-2001 Outline of Investigation for Compatibility of Insulating Materials and Refrigerant Oil for Use in Hermetic Refrigerant Motor-Compressors (Issue 2)《用于密封制冷电机压缩机的.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、October 18, 20011SUBJECT 984AOUTLINE OF INVESTIGATIONFORCOMPATIBILITY OF INSULATING MATERIALS AND REFRIGERANT/OILFOR USE IN HERMETIC REFRIGERANT MOTOR-COMPRESSORSIssue Number: 2OCTOBER 18, 2001COPYRIGHT 2001 UNDERWRITERS LABORATORIES INC.OCTOBER 18, 2001SUBJECT 984A2No Text on This PageCONTENTSFOREW
2、ORD 4INTRODUCTION1 Scope .52 General 52.1 Undated references .52.2 Units of measurement .5PERFORMANCE3 General 54 Samples .55 Test Environment .66 Temperature Exposure Refrigerant and Oil Atmosphere .77 Dielectric Voltage-Withstand Test .7OCTOBER 18, 2001 SUBJECT 984A 3FOREWORDA. This Outline of Inv
3、estigation contains basic requirements for products covered by UnderwritersLaboratories Inc. (UL) under its Follow-Up Service for this category within the limitations given below andin the Scope section of this Outline of Investigation. They are subject to revision as further experience andinvestiga
4、tion may show is necessary or desirable.B. The observance of these requirements by a manufacturer is one of the conditions of the continuedcoverage of the manufacturers product.C. A product which complies with the text of this Outline of Investigation will not necessarily be judged tocomply with the
5、 Outline of Investigation if, when examined and tested, it is found to have other featureswhich impair the level of safety contemplated by these requirements.D. A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements
6、 in this Outline of Investigation, and that involves a risk of fire orof electric shock or injury to persons shall be evaluated using appropriate additional component andend-product requirements to maintain the level of safety as originally anticipated by the intent of thisOutline of Investigation.
7、A product whose features, characteristics, components, materials, or systemsconflict with specific requirements or provisions of this Outline of Investigation does not comply with thisOutline of Investigation. Revision of requirements shall be proposed and adopted in conformance with themethods empl
8、oyed for development, revision, and implementation of this Outline of Investigation.E. UL, in performing its functions in accordance with its objectives, does not assume or undertake todischarge any responsibility of the manufacturer or any other party. The opinions and findings of ULrepresent its p
9、rofessional judgement given with due consideration to the necessary limitations of practicaloperation and state of the art at the time the Outline of Investigation is processed. UL shall not beresponsible to anyone for the use of or reliance upon this Outline of Investigation by anyone. UL shall not
10、incur any obligation or liability for damages, including consequential damages, arising out of or inconnection with the use, interpretation of, or reliance upon this Outline of Investigation.F. Many tests required by the Outline of Investigations of UL are inherently hazardous and adequatesafeguards
11、 for personnel and property shall be employed in conducting such tests.OCTOBER 18, 2001SUBJECT 984A4INTRODUCTION1 Scope1.1 These requirements cover an alternative compatibility test. The test requirements contained in thisoutline may be performed to evaluate the compatibility of an alternative refri
12、gerant and/or oil with electricalinsulating materials and systems used within the compressor-motor enclosure.2 General2.1 Undated references2.1.1 Any undated reference to a code or standard appearing in the requirements of this standard shallbe interpreted as referring to the latest edition of that
13、code or standard.2.2 Units of measurement2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.PERFORMANCE3 General3.1 Film or film and fiber coated magnet wire, motor ground insulation and other motor insulation systemparts, suc
14、h as lead connection blocks, tapes, lead wire, splice insulation, tie cords, phase barriers, thermalprotector coverings, tubing, varnish, etc. employed in the previously evaluated insulating system may betested. Motor-compressors, motorettes or coilettes along with other material to represent the sy
15、stem forthis testing may also be used. The use of other test methods judged equivalent by the certificationorganization that contain specific pass/fail criteria may also be considered.4 Samples4.1 Two twisted pairs of film or film and fiber coated magnet wire made in accordance with Standard TestMet
16、hod for Thermal Endurance of Film-Insulated Round Magnet Wire, ASTM D2307, or two straightlengths of fibrous-covered magnet wire, whichever is applicable, are to be tested.Exception: At the manufacturers option, six samples may be tested.4.2 If twisted pairs of film or film and fiber coated magnet w
17、ire are not used, two motorettes or coilettesare to be tested. Motorettes are to be prepared as described in IEEE 117, Standard Test Procedure forEvaluation of Systems of Insulating Materials for Random Wound AC Electric Machinery. Form woundmotorettes constructed to IEEE 117 shall be used for evalu
18、ating insulation systems rated over 600 V.Coilettes are to include a typical slot assembly fabricated from two metal plates bolted together. The slotsection of the motorette or coilette shall be fabricated from steel sheets, such as AISI 1010 cold-rolledsteel or other motor-steel sheets. The assembl
19、ed slot portion shall contain two coils approximately 15 to20 turns each, insulated from ground by slot cells, insulated from each other by phase insulation if usedin the motor application, and held in place with slot wedges. Form wound motorettes shall use rectangularwire with 5 turns per coil. Eac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT984A2001OUTLINEOFINVESTIGATIONFORCOMPATIBILITYOFINSULATINGMATERIALSANDREFRIGERANTOILFORUSEINHERMETICREFRIGERANTMOTORCOMPRESSORSISSUE2

链接地址:http://www.mydoc123.com/p-1069522.html