《UL SUBJECT 943C-2012 OUTLINE OF INVESTIGATION FOR SPECIAL PURPOSE GROUND-FAULT CIRCUIT-INTERRUPTERS (Issue 2)《专用接地故障断路器的调查大纲 (议题2)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 943C-2012 OUTLINE OF INVESTIGATION FOR SPECIAL PURPOSE GROUND-FAULT CIRCUIT-INTERRUPTERS (Issue 2)《专用接地故障断路器的调查大纲 (议题2)》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNovember 2, 20121UL 943COUTLINE OF INVESTIGATIONFORSPECIAL PURPOSE GROUND-FAULT CIRCUIT-INTERRUPTERSIssue Number 2November 2, 2012Summary of TopicsThis is the second issue of the Outline of Inves
2、tigation for SpecialPurpose Ground-Fault Circuit-Interrupters, Subject 943C, includingrevisions to the grounding monitor/interrupter, supervisory circuit, andmarking requirements, and including the addition of requirements forprogrammable circuit components and environmental sequence.COPYRIGHT 2012
3、UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 2, 2012UL 943C2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUC
4、TION1 Scope .42 Glossary .63 Components 64 Units of Measurement .75 Undated References 7CONSTRUCTION6 General 77 Grounding Circuit .78 Spacings .89 Grounding Monitor/Interrupter 910 Insulation .911 Supervisory Circuit .912 Programmable Circuit Components .10PERFORMANCE13 General 1114 Environmental T
5、est Sequence 1115 High Resistance Ground-Fault Test .1316 Grounded Neutral Test 1417 Resistance to False Tripping Test 1418 Grounding Monitor/Interrupter Test 1419 Overload and Motor Starting .1620 Low Resistance Ground Fault 1621 Endurance Test 1622 Surge Current Test .1823 Abnormal Overvoltage Tes
6、t 1824 Extra Low Resistance Ground Fault Test 1925 Short Circuit Test .19MARKINGS26 General 2027 Class Marking 2028 Other Markings .2029 Instructions 21APPENDIX A Sample Calculation of Grounding Conductor SizeA1 Sample Calculation of Grounding Conductor Size A1NOVEMBER 2, 2012 UL 943C 3UL COPYRIGHTE
7、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover ground-fault circuit-interrupters intended for use in one of the followingapplications:a) Where the voltage to ground is greater than 150 volts and equipment gr
8、ounding or doubleinsulation is required by the National Electrical Code, ANSI/NFPA 70,b) Where the voltage to ground is 150 volts or less and equipment grounding or double-insulation is provided, but the use of a Class A ground-fault circuit-interrupter is not practical.1.2 Ground-fault circuit-inte
9、rrupters addressed by these requirements are divided into three classes,Class C, D and E, based upon voltage rating and the characteristics of the grounding circuit. Some areintended for use in circuits where grounding is not provided to the load but double-insulation is provided.1.3 These ground-fa
10、ult circuit-interrupters are intended to be applied on circuits as shown in Figure 1.1.The requirements for Class A ground-fault circuit-interrupters are in the Standard for Ground-FaultCircuit-Interrupters, UL 943.This is generated text for figtxt.NOVEMBER 2, 2012UL 943C4UL COPYRIGHTED MATERIAL NOT
11、 AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 1.1Application of GFCIsNOVEMBER 2, 2012 UL 943C 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 Glossary2.1 For the purposes of this Outline of Investigati
12、on, the following definitions apply. Additional definitionsare in the Glossary of the Standard for Ground-Fault Circuit-Interrupters, UL 943.2.2 CLASS C GROUND-FAULT CIRCUIT-INTERRUPTER A ground-fault circuit-interrupter that isintended to be used in circuits with no conductor over 300 V AC to groun
13、d where reliable equipmentgrounding or double insulation is provided.2.3 CLASS D GROUND-FAULT CIRCUIT-INTERRUPTER A ground-fault circuit-interrupter that isintended to be used in circuits with one or more conductors over 300 volts to ground, and with speciallysized, reliable grounding, to provide a
14、low impedance path so that the voltage across the body during afault does not exceed 150 volts.2.4 CLASS E GROUND-FAULT CIRCUIT-INTERRUPTER A ground-fault circuit-interrupter that isintended to be used in circuits with one or more conductors over 300 volts to ground but withconventional equipment gr
15、ounding provided for the protected equipment in the system or doubleinsulation. These ground-fault circuit-interrupters respond rapidly to open the circuit before themagnitude and duration of the current flowing through the persons body exceeds the limits forventricular fibrillation.2.5 GROUNDING MO
16、NITOR/INTERRUPTER A device that monitors equipment grounding continuityin a protected system. It prevents the circuit from being energized under conditions where the groundingis not available and causes the circuit to be interrupted where the grounding is lost during operation.2.6 SPECIALLY SIZED GR
17、OUND A grounding conductor whose size is based on a ratio withrespect to the size of the ungrounded conductor in order to limit the voltage to which a person would beexposed in the event of a fault to ground.3 Components3.1 Except as indicated in 3.2, a component of a product covered by this Outline
18、 of Investigation shallcomply with the requirements for that component.3.2 A component need not comply with a specific requirement that:a) Involves a feature or characteristic not needed in the application of the component in theproduct covered by this Outline of Investigation, orb) Is superseded by
19、 a requirement in this Outline of Investigation.3.3 A component shall be used in accordance with its recognized rating established for the intendedconditions of use.3.4 Specific components are recognized as being incomplete in construction features or restricted inperformance capabilities. Such comp
20、onents are intended for use only under limited conditions, such ascertain temperatures not exceeding specified limits, and shall be used only under those specific conditionsfor which they have been recognized.NOVEMBER 2, 2012UL 943C6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORD
21、ISTRIBUTION WITHOUT PERMISSION FROM UL4 Units of Measurement4.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.5 Undated References5.1 Any undated reference to a code or standard appearing in the requirements of this Outline ofI
22、nvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 The products covered by this Outline shall comply with the construction requirements of the Standardfor Ground-Fault Circuit-Interrupters, UL 943, except as modified by these requir
23、ements.7 Grounding Circuit7.1 Except as noted in 7.2, the grounding circuit of the circuit in which these ground-faultcircuit-interrupters are used shall be continuous, of low resistance, and reliable.7.2 Equipment grounding is not required in the circuit to the load if the load is double insulated.
24、 See 10.2.7.3 The grounding circuit of the circuit in which a Class D ground fault circuit-interrupter is used shall beof sufficiently low impedance that, should a fault to ground occur, the voltage resulting across thegrounding circuit shall not exceed 150 volts. The size of the grounding conductor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT943C2012OUTLINEOFINVESTIGATIONFORSPECIALPURPOSEGROUNDFAULTCIRCUITINTERRUPTERSISSUE2 专用 接地 故障

链接地址:http://www.mydoc123.com/p-1069516.html