《UL SUBJECT 907A-2007 OUTLINE OF INVESTIGATION FOR FACTORY-BUILT TERMINATION CAPS FOR USE WITH MASONRY CHIMNEYS (Issue 1)《砖石结构烟囱用工厂制端帽调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 907A-2007 OUTLINE OF INVESTIGATION FOR FACTORY-BUILT TERMINATION CAPS FOR USE WITH MASONRY CHIMNEYS (Issue 1)《砖石结构烟囱用工厂制端帽调查大纲 发布编号 1》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAugust 23, 20071SUBJECT 907AOUTLINE OF INVESTIGATIONFORFACTORY-BUILT TERMINATION CAPS FOR USE WITH MASONRYCHIMNEYSIssue Number: 1AUGUST 23, 2007Summary of TopicsThis is the first issue of the Out
2、line of Investigation for Factory-Built Termination Caps for Use with Masonry ChimneysThe UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULSt
3、andardsInfoNet at: http:/ 2007 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 23, 2007SUBJECT 907A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT
4、 PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .54 Undated References 55 Glossary .5CONSTRUCTION6 Materials .57 Assembly 5PERFORMANCE8 General 69 Strength Tests 69.1 General .69.2 Crushing and joint load test 79.3 Wind load tests .710 Rain Test .711 Draft Loss
5、Test 7MARKING12 General .8INSTALLATION AND MAINTENANCE INSTRUCTIONS13 General .8PACKING FOR SHIPMENT14 General .9AUGUST 23, 2007 SUBJECT 907A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover term
6、ination caps for attachment at the termination of a masonry residentialchimney constructed in accordance with the Standard for Chimneys, Fireplaces, Vents, and SolidFuel-Burning Appliances, NFPA 211 and applicable codes such as the International Residential Code(IRC), International Mechanical Code (
7、IMC), and Uniform Mechanical Code (UMC).1.2 These requirements cover termination caps intended for use with masonry residential chimneysprovided with a clay-flue lining complying to the requirements of Standard Specification for Clay FlueLiners and Chimney Pots, ASTM C 315.1.3 Requirements for termi
8、nation caps intended for use with flue liners are covered by the Standard forChimney Liners, UL 1777.1.4 Requirements for termination caps intended for use with factory-built chimneys are covered by theStandard for Factory-Built Chimneys for Residential Type and Building Heating Appliances, UL 103.1
9、.5 Requirements for termination caps intended for use with factory-built fireplaces are covered by theStandard for Factory-Built Fireplaces, UL 127.1.6 Factory-built termination caps for use with masonry residential chimneys are intended for installationin single cap applications only.1.7 Terminatio
10、n caps covered by these requirements are not intended for use on chimneys with multipleflues or for use with multiple chimneys.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirements for that component.2.2 A component is not requ
11、ired to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with its rating established
12、for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under tho
13、se specific conditions.AUGUST 23, 2007SUBJECT 907A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information
14、.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purposes of this outline, the following definitions apply.5.2 MASONRY CHIMNEY A fie
15、ld constructed chimney of solid masonry units, bricks, stones, orreinforced portland-cement concrete, lined with a clay-flue lining complying to the requirements ofStandard Specification for Clay Flue Liners and Chimney Pots, ASTM C315.5.3 MASONRY FIREPLACE A field-constructed assembly constructed i
16、n accordance with theStandard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, NFPA 211, or inaccordance with the International Residential Code, (IRC)5.4 TERMINATION CAP A protective covering or housing attached to the chimney liner terminusintended for preventing entry of rain,
17、snow and provided with a spark arrester.CONSTRUCTION6 Materials6.1 A factory-built termination cap for use with masonry chimneys shall comply with the “Materials”section of the Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances,UL 103.7 Assembly7.1 A factory-bui
18、lt termination cap for use with masonry chimneys shall comply with the “Assembly”Section of the Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances,UL 103.7.2 A factory-built termination cap for use with masonry chimneys shall be completely assembled by themanufa
19、cturer at the factory.Exception: A factory-built termination cap may be packaged in a kit form provided, all required pieces,including fasteners, are packaged in the kit and no fabrication such as cutting, drilling or punching holesis required for assembly.AUGUST 23, 2007 SUBJECT 907A 5UL COPYRIGHTE
20、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.3 A factory-built termination cap for use with masonry chimneys shall comply with the “Joints” sectionof the Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances, UL 103.
21、7.4 A factory-built termination cap shall be provided with a positive means to limit overlap or engagementto the specified liner sizes. Such means shall be permanently assembled by the manufacturer, shall notbe removable by hand or with simple hand tools and the exception to 7.2 shall not apply.7.5
22、Compliance with 7.4 shall be determined by trial fit to each size and geometric shape of linernecessary and meeting the requirements of Section 9.2, Crushing and Joint Load Test.7.6 A factory-built termination cap for use with masonry chimneys shall comply with the “Rain Caps”section of the Standard
23、 for Factory-Built Chimneys for Residential Type and Building Heating Appliances,UL 103.7.7 A factory-built termination cap for use with masonry chimneys shall be designed to be removable andreplaceable without tools or by the use of common hand tools.7.8 A factory-built termination cap for use with
24、 masonry chimneys shall employ a spark arrester as partof the construction as described by Section 4.6.3, Spark Arresters, of Standard for Chimneys, Fireplaces,Vents, and Solid Fuel Burning Appliances, NFPA 211.Exception: Material requirements shall be in accordance with 6.1.PERFORMANCE8 General8.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT907A2007OUTLINEOFINVESTIGATIONFORFACTORYBUILTTERMINATIONCAPSFORUSEWITHMASONRYCHIMNEYSISSUE1

链接地址:http://www.mydoc123.com/p-1069515.html