1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJanuary 30, 20171UL 8782Outline of Investigation for Pollution Control Units for Commercial CookingOperationsIssue Number: 1January 30, 2017Summary of TopicsThis is the first issue of the Outline
2、 of Investigation for Pollution ControlUnits for Commercial Cooking Operations, UL 8782.COPYRIGHT 2017 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJANUARY 30, 2017UL 87822No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
3、 FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Components 53 Units of Measurement .64 Undated References 65 Terminology 66 Glossary .6CONSTRUCTION7 Materials .78 Assembly 99 Joints .1010 Support Assembly 1011 Filters .1011.1 Electrostatic precipitator
4、.1011.2 Grease filters 1112 Electrical Enclosure .1112.1 General .1112.2 Transparent covers .1212.3 Battery storage compartments .1212.4 Ventilation openings 1313 Field-Wiring Connections 2013.1 General .2013.2 Grounding .2014 Internal Wiring 2114.1 General .2114.2 Wiring methods 2215 Separation of
5、Circuits .2316 Bonding For Grounding 2416.1 General .2416.2 Conductors 2517 Capacitors .2618 Overcurrent Protection 2719 Transformers .2720 Switches and Controllers 2821 Electrical Spacings - High-Voltage Circuits .2822 Electrical Spacing - Low-Voltage Circuits 30PERFORMANCE23 General .3024 Test Ins
6、tallations 3225 Temperature Measurement 3726 Temperature Test 500F (260C) Flue Gases 4227 Abnormal Temperature Test .4628 Leakage Test 4629 Water Spray Test .4830 Fire And Leakage Test of Pollution Control Unit Access Doors and Fittings 51JANUARY 30, 2017 UL 8782 3UL COPYRIGHTED MATERIAL NOT AUTHORI
7、ZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL31 Tensile Strength, Elongation, And Change in Volume Tests of Gaskets And Seals .5331.1 General .5331.2 Tensile strength and ultimate elongation tests .5331.3 Volume change test 54ELECTRICAL TESTS32 Overvoltage and Undervoltage O
8、peration Test .5533 Dielectric Voltage-Withstand Test .5534 Short-Circuit Test .56CONTROL UNIT TESTS35 General 5736 Heating Test .58MARKING37 General 61INSTRUCTIONS38 Installation Instructions 62APPENDIX AStandards for ComponentsA1JANUARY 30, 2017UL 87824UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU
9、RTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover commercial pollution control unit assemblies that are intended to beinstalled in line with commercial grease ducts used to exhaust heat, smoke, and grease-laden vapors fromcommercial cooking o
10、perations to the outdoors as specified in the Standard for Ventilation Control andFire Protection of Commercial Cooking Operations, NFPA 96, the International Mechanical Code, and theUniform Mechanical Code.1.2 These requirements include modular pollution control assemblies, unwelded connections bet
11、weenadjoining parts, fittings, access doors, and the like.1.3 These requirements do not address NFPA 96 and the International Mechanical Code requirementsfor pollution control unit fire resistive enclosures. Pollution control units covered only by theserequirements are intended to be installed in a
12、fire resistive enclosure when required by NFPA 96 or theIMC.1.4 Requirements used to evaluate the effectiveness of the combination of a pollution control unit and anenclosure as a fire rated enclosure system and through penetration firestop system, as well as theenclosures effect on the pollution co
13、ntrol unit are contained in Standard for Tests of Fire Resistive GreaseDuct Enclosure Assemblies, UL 2221, and ASTM E 2336, Standard Test Methods for Fire ResistiveGrease Duct Enclosure Systems.1.5 This Outline does not measure the efficacy of the pollution control unit to remove grease-ladeneffluen
14、t from the air stream, nor other factors that do not directly affect users or electrical and fire safety.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with therequirements for that component. See Appendix A for a list of standards covering
15、 components used in theproducts covered by this standard.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in t
16、his Outline of Investigation.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited con
17、ditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.JANUARY 30, 2017 UL 8782 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Values stated witho
18、ut parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall beinterpreted as referring to the latest edition of that code or standard.5 Ter
19、minology5.1 The term “pollution control unit” as used in these requirements refers to all pollution control units andpollution control unit assemblies covered by these requirements unless specifically noted otherwise.6 Glossary6.1 For the purpose of these requirements, the following definitions appl
20、y.6.2 ACCESS DOOR A door or cover plate that when opened provides a means for cleaning thepollution control unit.6.3 CIRCUIT, HIGH-VOLTAGE A circuit having characteristics in excess of those of a low-voltagecircuit. See 6.4.6.4 CIRCUIT, LOW-VOLTAGE A circuit involving a potential of not more than 30
21、 volts rmsalternating-current (42.4 volts peak or direct current), and supplied by a primary battery or by a Class 2transformer or by a combination of transformer and fixed impedance which, as a unit, complies with allthe performance requirements for a Class 2 transformer.6.5 COMBUSTIBLE MATERIAL Ma
22、terial made of or surfaced with wood, compressed paper, plainfibers, or other material that will ignite and burn, as applied to materials adjacent to or in contact withheat-producing appliances, pollution control unit and vent connectors, steam and hot water pipes, andwarm air ducts. Such material s
23、hall be considered as combustible even though flame-proofed,fire-retardant treated, or plastered.6.6 GREASE FILTER A removable component of the grease removal system intended to capturegrease and direct it to a safe collection point.6.7 NONCOMBUSTIBLE MATERIAL A material that, in the form in which i
24、t is used and under theconditions anticipated, will not ignite, burn, support combustion, or release flammable vapors whensubjected to fire or heat. Materials that are reported as passing ASTM E136, Standard Test Method forBehavior of Materials in a Vertical Tube Furnace at 750C, are considered nonc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT87822017OUTLINEOFINVESTIGATIONFORPOLLUTIONCONTROLUNITSFORCOMMERCIALCOOKINGOPERATIONSISSUE1PDF

链接地址:http://www.mydoc123.com/p-1069508.html