UL SUBJECT 867A-2014 UL Outline of Investigation for Commercial Industrial Indoor Air Quality Systems Ozone Generating Type (Issue 1)《臭氧发生类型的商业 工业室内空气质量系统的UL调查大纲 (议题1)》.pdf
《UL SUBJECT 867A-2014 UL Outline of Investigation for Commercial Industrial Indoor Air Quality Systems Ozone Generating Type (Issue 1)《臭氧发生类型的商业 工业室内空气质量系统的UL调查大纲 (议题1)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 867A-2014 UL Outline of Investigation for Commercial Industrial Indoor Air Quality Systems Ozone Generating Type (Issue 1)《臭氧发生类型的商业 工业室内空气质量系统的UL调查大纲 (议题1)》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 14, 20141UL 867AOutline of Investigation for Commercial/Industrial Indoor Air QualitySystems, Ozone Generating TypeIssue Number: 1February 14, 2014Summary of TopicsThis first issue of th
2、e Outline of Investigation for Commercial/IndustrialIndoor Air Quality Systems, Ozone Generating Type, UL 867A, covers aircleaners of the ozone generating type intended for commercial and/orindustrial applications and intended for permanent connection within theair handling systems.The effective dat
3、e for this first issue Outline is being determined.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outl
4、ines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 14, 2014UL 867A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTH
5、ORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components .53 Units of Measurement 54 Undated References 55 Glossary 5CONSTRUCTION6 General 67 Ozone Sensor and/or Detector .77.1 Reliability determination and failure rate calculation .77.2 Lam
6、ps 77.3 Sensor and/or detector reliability prediction .77.4 Compatibility 88 System Controls 9PERFORMANCE9 Sensitivity Requirement .109.1 General 109.2 Calibration 119.3 Test equipment .1110 Jarring Test 1111 Electrical Supervision .1311.1 General .1311.2 Component reliability data .1412 Audibility
7、Test 1512.1 General .1512.2 Sound output measurement .1513 Supplementary Remote Sounding Appliances 1614 Stability Test .1615 Ozone Output Verification 17MARKINGS16 Details 17INSTRUCTIONS17 Details .19FEBRUARY 14, 2014 UL 867A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRI
8、BUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements apply to indoor air quality systems of the ozone generating type intended forcommercial/industrial applications and intended for permanent connection within the air handling system.Sensors/detectors are provided but are not i
9、ntegrated with the system control. The sensors/detectorsprovide electrical feedback to the system control, regarding monitored ozone. The system controlresponds by adjusting or shutting down system operation and intended to monitor accumulated ozonebelow regulatory limits. These products are rated 6
10、00 volts or less and are intended to be employed inaccordance with the National Electrical Code, NFPA 70, and all applicable indoor air quality regulations.1.2 These requirements do not cover:a) Portable indoor air quality systems;b) Indoor air quality systems intended for use in hospitality and ins
11、titutional applications havingsleeping quarters, such as hotel guest rooms, nursing homes, dormitories, etc.;c) Indoor air quality systems intended for healthcare applications;d) Indoor air quality systems intended for installation in other than tertiary educationalinstitutions. Exclusion includes p
12、reschool, primary and secondary educational institutions;e) Indoor air quality systems relying on RF or other wireless transmission of signals betweendevices;f) Primary or secondary battery operated equipment;g) Emergency signaling equipment as addressed in Standards such as, but not limited to UL20
13、75, UL 2017, UL 268, UL 864, NFPA 72 and NFPA 720;h) Product performance and/or effectiveness in the management of indoor air qualityi) Sensors/detectors for other than ozone monitoring; andj) Indoor air quality system employing UV lamps.1.3 The equipment shall comply with the applicable requirement
14、s in the Standard for Electrostatic AirCleaners, UL 867, in addition to the requirements contained within this outline.FEBRUARY 14, 2014UL 867A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 Components2.1 Except as indicated in 2.2, a compo
15、nent of a product covered by this Outline of Investigation shallcomply with the requirements for that component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by
16、 this Outline of Investigation; orb) Is superseded by a requirement in this Outline of Investigation.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance
17、capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses a
18、re explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this Outline ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.5 Glossary5.1 COMPONENT, CRITICAL A component is
19、 considered critical if two or more failure modes of thecomponent, which will affect the intended operation or the sensitivity of the detector, sensor or alarm,do not result in a trouble signal.5.2 COMPONENT, CONDITIONALLY CRITICAL A component is considered conditionally critical ifonly one failure
20、mode of the component will affect the intended operation or the sensitivity of thedetector, sensor or alarm, and does not result in a trouble signal (A trouble signal is indicated byenergization of an audible signal and energization of a separate visual indication (amber or orange), orde-energizatio
21、n of a power-on light. The visual indication that is depended on to denote the visualportion of the trouble condition shall have a documented predicted failure rate of not greater than 2.5failures per million hours)5.3 COMPONENT, LIMITED-LIFE A component of a sensor/detector that is expected to fail
22、 and beperiodically replaced and the failure of which is supervised, when failure of the component affects theintended operation, sensitivity, or both. Typical examples of such components include incandescentlamps, electronic tube heaters, and functional heating elements.5.4 COMPONENT, NON-CRITICAL
23、A component is considered noncritical if all failure modes of thecomponent will result in a trouble signal, or have no effect on the intended operation of the detector,sensor or alarm for alarm and trouble signals, and will not affect the sensitivity of the device or system.FEBRUARY 14, 2014 UL 867A
24、 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL5.5 COMPONENT, RELIABLE A component of a sensor/detector that is not expected to fail or beperiodically replaced and is not supervised. A reliable component shall have a predicted failure rate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT867A2014ULOUTLINEOFINVESTIGATIONFORCOMMERCIALINDUSTRIALINDOORAIRQUALITYSYSTEMSOZONEGENERATINGTYPEISSUE1

链接地址:http://www.mydoc123.com/p-1069506.html