1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOctober 31, 20141UL 3456Outline of Investigation for Electric-Battery-Powered Carts For CommercialUseISSUE NO: 11OCTOBER 31, 2014Summary of TopicsThis is the eleventh issue of the Outline of Inve
2、stigation for Electric-Battery-Powered Carts For Commercial Use, Subject 3456, which includesa revision to Clause 23.1COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 31, 2014UL 34562No Text
3、on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Components 53 Units of Measurement .64 Undated References 65 Glossary .66 Reference Standards 87 Samples .8CONSTRUCTION8 General 89 Internal Wiring 910
4、 Motors and Electromechanical Brakes .1011 Switches and Motor Contactors .1012 Battery Chargers .1113 Inverters and Converters 1114 Lights and Audible Devices 1115 Batteries .1116 Electrical Enclosures 1216.1 General .1216.2 Nonmetallic enclosures .1216.3 Metallic enclosures .1217 Nonmetallic Electr
5、ical Insulation 1318 Printed-Wiring Boards .1719 Limited Power Circuit 1720 Electrical Spacings 1721 Separation of Circuits .1822 Control Circuits .1923 Overcurrent Protection 2024 Tires and Static Discharge Devices .2125 Battery Compartment or Enclosure 2126 Protection Against Injury to Persons 212
6、6.1 General .2126.2 Sharp edges .2226.3 Stability .2226.4 Enclosures and guards .2226.5 Accessibility of uninsulated live parts, film-coated wire, and moving parts .23PERFORMANCE27 Static Stability Test .2828 Static Loading Test .3028.1 General .3028.2 Seat 3028.3 Arm rest .3028.4 Steering handle 31
7、28.5 Floorboard 3128.6 Load basket .31OCTOBER 31, 2014 UL 3456 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL29 Output Test (Maximum Speed) .3130 Dynamic Abnormal Loading Test .3231 Dynamic Stability Test .3332 Turning Dynamic Stability Tes
8、t .3633 Brake Holding Test .3634 Temperature Test .3635 Brake Test .4236 Arc-Rupture Test .4337 Motor Burnout Test .4438 Dielectric Voltage Withstand Test .4539 Limited Power Circuits Test 4540 Elements Exposure Test .4741 Rain Test 4842 Electromagnetic Compatibility Test 5143 Static Discharge Test
9、.51MARKINGS44 Details .51SERVICE MANUAL45 Details .53MANUFACTURING AND PRODUCTION TESTS46 Production-Line Dielectric Voltage-Withstand Test 53ELECTRICAL ACCESSORIES FOR FIELD INSTALLATION BY QUALIFIED PERSONNEL47 Construction .5448 Markings .5449 Instructions 55APPENDIX AStandards for ComponentsA1OC
10、TOBER 31, 2014UL 34564UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover electric-battery-powered carts designed for a single user for indoorcommercial use with respect to a risk of fire, electric s
11、hock, and personal injury.1.2 These requirements cover electric-battery-powered carts powered by batteries supplying 42.2 Vac(peak) or 60 Vdc or less.1.3 The electric-battery-powered cart shall be equipped with no less than 3 wheels, not including anti-tipdevices.1.4 The maximum speed shall not exce
12、ed 3 mph (4.8 kph).1.5 These requirements do not cover electric-battery-powered carts intended for recreational, residentialor industrial use.1.6 The requirements do not cover electric-battery-powered carts for use in hazardous locations.2 Components2.1 Except as indicated in 2.2, a component of a p
13、roduct covered by this outline shall comply with therequirements for that component. They shall be located and secured so that they are not adverselyaffected by vibration, temperature, environment and other effects during normal operation. See AppendixA for a list of standards covering components ge
14、nerally used in the products covered by this outline.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this
15、outline.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as cert
16、ain temperatures notexceeding specified limits, and shall be used only under those specific conditions.OCTOBER 31, 2014 UL 3456 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Values stated without parentheses are th
17、e requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpo
18、se of this outline, the following definitions apply.5.2 ANTI-TIP DEVICE A component to limit the extent of tipping the cart.5.3 CART Electric battery powered cart intended for a single user.5.4 CIRCUIT CLASSIFICATIONS:a) High-Voltage Circuit A circuit of a potential having characteristics in excess
19、of those of alow-voltage circuit.b) Low-Voltage Circuit A circuit involving a peak open-circuit potential of not more than 60Vdc or 30 Vrms (42.4 Vac peak) supplied by a battery, a Class 2 transformer, or by acombination of a transformer and a fixed impedance that as a unit, complies with allperform
20、ance requirements for a Class 2 transformer. A circuit derived by connecting aresistance in series with a voltage supply circuit as a means of limiting the voltage and current,is not considered to be a low-voltage circuit.c) Power-Limited Circuit A circuit wherein the power is limited from a source
21、whose opencircuit voltage is less than or equal to 60 Vdc and whose maximum current and power after 60s of operation comply with the values outlined in Tables 39.1 and 39.2. Limited power controlcircuits shall comply with the Standard for Automatic Electrical Controls for Household andSimilar Use, P
22、art 1: General Requirements, UL 60730-1.5.5 CONTROL CIRCUIT A circuit that is considered neither a Power, Low-Voltage, or Limited PowerCircuit. Also, a circuit which supplies a motor that has a locked-rotor current of 15 amperes or less, andis protected by an overcurrent device having a maximum rati
23、ng or setting of 15 amperes.5.6 ELECTROSTATIC DISCHARGE (ESD) Discharge created by static electricity.5.7 OPERATING CONTROL Control which starts or regulates the equipment during normaloperation.5.8 POWER CIRCUIT A circuit that has a source of supply capable of short circuit currents greaterthan 15
24、amperes, and that is not protected by an overcurrent device having a maximum rating or settingof 15 amperes. Also, a circuit is considered a power circuit if it supplies a motor except as noted in thecontrol circuit definition.5.9 PROTECTIVE CONTROL Automatic controls and interlocks including relays
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT34562014ULOUTLINEOFINVESTIGATIONFORELECTRICBATTERYPOWEREDCARTSFORCOMMERCIALISSUE11PDF

链接地址:http://www.mydoc123.com/p-1069410.html