《UL SUBJECT 327-2011 OUTLINE OF INVESTIGATION FOR TURBINE TYPE FLOW METERS FOR FIRE PROTECTION SYSTEMS (Issue Number 5)《防火系统的涡轮型流量计的调查大纲》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 327-2011 OUTLINE OF INVESTIGATION FOR TURBINE TYPE FLOW METERS FOR FIRE PROTECTION SYSTEMS (Issue Number 5)《防火系统的涡轮型流量计的调查大纲》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJanuary 25, 20111SUBJECT 327OUTLINE OF INVESTIGATIONFORTURBINE TYPE FLOW METERS FOR FIRE PROTECTION SYSTEMSIssue Number 5January 25, 2011Summary of TopicsThis is the Fifth Issue of the Outline of
2、 Investigation for Turbine TypeFlow Meters for Fire Protection Systems, Subject 327, including revisionsto the Outline title, the Scope, and the Construction and Performancerequirements; and the addition of the Glossary and the requirements forInstructions.This issue becomes effective January 25, 20
3、11, except for the CalibrationTest, Section 17, which becomes effective January 25, 2013. See theCalibration Test, Section 14 of the Fourth Issue for the currentrequirements until the effective date is met.COPYRIGHT 2011 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE
4、R REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJANUARY 25, 2011SUBJECT 3272No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Glossary .54 Units of Measurement .65 Undated
5、 References 6CONSTRUCTION6 General 67 Sizes 68 Rated Pressure .69 Nonmetallic Materials 610 Type I and Type II Meter Assemblies .711 Strainers 7PERFORMANCE12 General .713 Nonmetallic Materials Test 713.1 Plastic or other nonmetallic parts (excluding rubber and synthetic elastomers) 713.2 Elastomeric
6、 parts (excluding gaskets) 814 Leakage Test 915 Hydrostatic Test .916 Hydraulic Friction Loss Test .917 Calibration Test .1018 Endurance Test 10MANUFACTURING AND PRODUCTION TESTS19 General 11MARKING20 General 11INSTRUCTIONS21 General 12JANUARY 25, 2011 SUBJECT 327 3UL COPYRIGHTED MATERIAL NOT AUTHOR
7、IZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTIONSee Section 14 of the Fourth Issue for the current requirements for the Calibration Test, Section 17 of thisIssue, until the effective date is met.1 Scope1.1 These requirements cover the construction and performance o
8、f turbine type water flowmeters for fireprotection service of Type I, Type II or Type III construction.1.2 The following items are outside the scope of these requirements:a) Materials and construction of the register;b) Evaluation of the by-pass components, including the by-pass meter if provided, e
9、xcept forbody leakage and strength of body;c) Potability and;d) Stationary static gaskets, such as cover gaskets and ring gaskets used between flanges.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline shall comply with therequirements for that component.2.2
10、 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this Outline; orb) Is superseded by a requirement in this Outline.2.3 A component shall be used in accordance with
11、 its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shal
12、l be used only under those specific conditions.JANUARY 25, 2011SUBJECT 3274UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Glossary3.1 For the purpose of these requirements, the following definitions apply.3.2 NPS (NOMINAL PIPE SIZE) A dimen
13、sionless designator for pipe sizes defined in standards,including the Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded andSeamless, ASTM A53/A53M, the Standard Specification for Electric-Resistance-Welded Steel Pipe,ASTM A135/A135M, and the Standard Specification for
14、 Black and Hot-Dipped Zinc-Coated (Galvanized)Welded and Seamless Steel Pipe for Fire Protection Use, ASTM A795/A795M, used to replace termssuch as “Nominal Diameter” and “Nominal Size”.3.3 TYPE I METER A proportional meter assembly with a by-pass line consisting of:a) A detector type valve that rem
15、ains closed under low water flow conditions and diverts thelow flow through;b) A bypass meter;c) A main body with an unobstructed waterway with the same internal diameter of the pipe; andd) A turbine type meter located in the main body that passes and meters a portion of the totalvolume of water thr
16、ough the main body.3.4 TYPE II METER A meter assembly with a by-pass line consisting of:a) A detector type valve that remains closed under low water flow conditions and diverts thelow flow through;b) A bypass meter;c) A Strainer; andd) A main line turbine meter located in the main body that allows h
17、igh rates of water flow topass through the main body.3.5 TYPE III METER A meter assembly consisting of:a) A Strainer and;b) A main line turbine meter located in the main body through which the entire water volumeflows.JANUARY 25, 2011 SUBJECT 327 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
18、EPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Units of Measurement4.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.5 Undated References5.1 Any undated reference to code or standard appearing in the requirements of thi
19、s outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 The meter is to be designed and constructed to comply with the applicable portions of the AmericanWater Works Association (AWWA) Standard for Cold-Water Meters Fire Service Type, AWWA C
20、703,including body materials and by-pass meters.7 Sizes7.1 A meter shall be constructed for use with standard pipe of size (NPS), 3 NPS or larger.7.2 Meter sizes refer to the nominal diameter of the waterway through the inlet and outlet connectionsand to the pipe size for which the connections are i
21、ntended.8 Rated Pressure8.1 A meter shall be constructed for a minimum rated pressure of 175 psig.9 Nonmetallic Materials9.1 A plastic or other nonmetallic part, other than rubber parts such as seals and O rings, is to bejudged on the basis of:a) Mechanical strength;b) Water absorption;c) Resistance
22、 to deterioration due to aging; andd) Volumetric and dimensional changes. See 13.1.1.1 13.1.2.2.9.2 A rubber part or synthetic elastomer of such type used in a meter assembly is to be judged on thebasis of tensile strength, elongation, and resistance to aging. See 13.2.1.JANUARY 25, 2011SUBJECT 3276
23、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10 Type I and Type II Meter Assemblies10.1 Type I and Type II meters shall be constructed such that the detector portion of the meter consistsof a detector check valve complying with the Standard
24、 for Check Valves for Fire-Protection Service, UL312.10.2 Type I and Type II meters with integral detector check valves shall comply with the applicablerequirements of the Standard for Check Valves for Fire-Protection Service, UL 312.11 Strainers11.1 For meters that require strainers, strainers shal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT3272011OUTLINEOFINVESTIGATIONFORTURBINETYPEFLOWMETERSFORFIREPROTECTIONSYSTEMSISSUENUMBER5 防火

链接地址:http://www.mydoc123.com/p-1069399.html