UL SUBJECT 321-2006 Outline of Investigation for Pipeline Strainers (Issue 3)《管道滤器的调查大纲 发布编号 3》.pdf
《UL SUBJECT 321-2006 Outline of Investigation for Pipeline Strainers (Issue 3)《管道滤器的调查大纲 发布编号 3》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 321-2006 Outline of Investigation for Pipeline Strainers (Issue 3)《管道滤器的调查大纲 发布编号 3》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNovember 15, 20061SUBJECT 321OUTLINE OF INVESTIGATIONFORPIPELINE STRAINERSIssue Number: 3NOVEMBER 15, 2006Summary of TopicsThis new issue of SU 321 is being issued through ULs electronicpublishin
2、g system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStan
3、dard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNOVEMBER 15, 2006SUBJECT 3212No Text on This PageUL COPYRIGHTED MATERIAL
4、 NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSGENERAL1 Scope .4CONSTRUCTION2 General 4PERFORMANCE3 Leakage and Hydrostatic Strength 44 Friction Loss .55 Strength of Materials 56 Marking 5NOVEMBER 15, 2006 SUBJECT 321 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED
5、 FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULGENERAL1 Scope1.1 These requirements cover pipeline strainers for fire protection service. These devices are intended foruse in fire service systems such as sprinkler systems installed in accordance with the Standard forSprinkler Sys
6、tems, NFPA 13, and fixed water spray systems installed in accordance with the Standard forWater Spray Fixed Systems, NFPA 15, where protection against clogging of water discharge is needed.CONSTRUCTION2 General2.1 Pipeline strainers for fire protection service shall have a minimum rated working pres
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT3212006OUTLINEOFINVESTIGATIONFORPIPELINESTRAINERSISSUE3 管道 滤器 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069397.html