1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOctober 7, 20161UL 2996Outline of Investigation for In-Ground BoxesIssue Number: 1October 7, 2016Summary of TopicsThe is the First Issue of the Outline of Investigation for In-Ground Boxes,UL 299
2、6, for use in accordance with the National Electrical Code,ANSI/NFPA 70. In-Ground Boxes are intended to provide permanent powerin open spaces. The need and desire to utilize commercial outdoor spacefor more than recreation is on the rise in Corporate, Educational andHospitality sectors. Companies a
3、re creating spaces outdoors, allowingemployees to Improve Working Environment, Increase Productivity andStimulate Creativity. Universities regularly hold classes and othereducational events outdoors. Hotels and Conference Centers are adaptingoutdoor spaces to increase revenue by offering Social Even
4、ts andBusiness Meetings. Questions regarding interpretation of requirementsshould be directed to the responsible UL Staff.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of I
5、nvestigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 7, 2016UL 29962
6、No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Normative References .43 Glossary .54 General Requirements 5CONSTRUCTION5 General 6PERFORMANCE6 Performance Electrical Enclosures 66.1 Volume v
7、erification test .66.2 Dielectric voltage withstand .76.3 Water absorption .76.4 Flammability .86.5 Electrical enclosures of an in-ground box 106.6 Mold stress 126.7 Resistance to crushing 136.8 Resistance to Impact 136.9 Threaded or Unthreaded Holes for Screws in Molded Bosses 147 Performance In-Gr
8、ound Box .157.1 Environmental tests 157.2 Structural load tests on full-size products .167.3 Static friction test .178 Performance In-Ground Box, Electrical Enclosure Assembly 188.1 Resistance to ultraviolet light and water .188.2 Pressure test .188.3 Icing .198.4 Gasket tests 199 Marking .2110 Use
9、and Installation Instructions .22OCTOBER 7, 2016 UL 2996 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline of investigation covers in-ground boxes with integral electrical enclosure(s) for housingwiring devic
10、es connected to a branch circuit. The unit is intended to be installed outdoors and in theground. The unit provides access to one or more receptacle outlets and is intended to be installed inaccordance with the National Electrical Code, NFPA 70, the NEC.1.2 This outline does not cover in-ground boxe
11、s for use in hazardous locations as defined in the NationalElectrical Code, NFPA 70.2 Normative References2.1 Products covered by this outline shall comply with the reference installation codes and standard asappropriate for the country where the product is to be used. When the product is intended f
12、or use in morethan one country, the product shall comply with the installation codes and standards for all countrieswhere it is intended to be used.2.2 Where reference is made to any Standard, such reference shall be considered to refer to the latestedition and revisions thereto available at the tim
13、e of printing, unless otherwise specified.2.3 ASTM C1028, Standard Test Method for Determining the Static Coefficient of Friction of Ceramic Tileand Other Like Surfaces by the Horizontal Dynamometer Pull-Meter Method2.4 ASTM D543, Standard Practices for Evaluating the Resistance of Plastics to Chemi
14、cal Reagents2.5 ASTM D570, Standard Test Method for Water Absorption of Plastics2.6 ASTM D635, Standard Test Method for Rate of Burning and/or Extent and Time of Burning Plasticsin a Horizontal Position2.7 ASTM D2444, Standard Test Method for Determination of the Impact Resistance of ThermoplasticPi
15、pe and Fittings by Means of a Tup (Falling Weight)2.8 ASTM G154, Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure ofNonmetallic Materials2.9 US Dept. of Agriculture, Rural Utilities Service, RUS 7 CFR 1755.910, Specification for Outside PlantHousings and Serving Area Inter
16、face SystemsOCTOBER 7, 2016UL 29964UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Glossary3.1 IN-GROUND BOX A vault intended to be buried outdoors which allows access to one or morepower outlets.3.2 ELECTRICAL ENCLOSURE A compartment of an
17、in-ground box relied upon to provide electrical ormechanical protection intended to house electrical connections, splices, wiring devices, etc.Note: the term enclosure used in 6.4.1.2 and Figure 6.1, refer to the three sided test enclosure.4 General Requirements4.1 Except as indicated in 4.2, a comp
18、onent of a product covered by this outline shall comply with therequirement for that component. A component shall comply with the ANCE, CSA, or UL standards asappropriate for the country where the product is to be used.4.2 A component is not required to comply with a specific requirement that:a) Inv
19、olves a feature or characteristic not required in the application of the component in theproduct covered by this outline; orb) Is superseded by a requirement in this outline.4.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.4.4 The values given
20、 in SI (metric) units shall be normative. Any other values given shall be forinformation purposes only.4.5 Each part of an in-ground box shall be so designed and constructed that, when mounted and installedas for normal use, the in-ground box ensures:a) Adequate electrical and mechanical protection
21、to the parts enclosed and minimizes dangerto the user or surroundings;b) Accessible outlets are protected when the box cover is closed; andc) Ground water does not enter in to the wiring space.OCTOBER 7, 2016 UL 2996 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WIT
22、HOUT PERMISSION FROM ULCONSTRUCTION5 General5.1 The electrical enclosure portions of in-ground boxes shall comply with all of the applicableconstruction requirements in the Standard for Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers,UL 514C.5.2 In-ground boxes shall be designed such that o
23、utlets that are accessible when the enclosure cover isopened are suitably protected from ground water when the cover is closed.5.3 All electrical enclosures and components intended to be submerged while this product is installedshall be rated Type 6 or Type 6P in accordance with the Standard for Enc
24、losures for Electrical Equipment,Environmental Considerations, UL 50E.5.4 An in-ground box shall have a means of securing the cover in the closed position both when in useand when not in use.5.5 Receptacle types 5-15R, 5-20R, 6-15R and 6-20R provided with an in-ground box shall be ratedWeather Resis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT29962016OUTLINEOFINVESTIGATIONFORINGROUNDBOXESISSUE1PDF

链接地址:http://www.mydoc123.com/p-1069385.html