UL SUBJECT 2988-2016 Outline of Investigation for Universal Hybrid Power and Signal Control (Issue 1).pdf
《UL SUBJECT 2988-2016 Outline of Investigation for Universal Hybrid Power and Signal Control (Issue 1).pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2988-2016 Outline of Investigation for Universal Hybrid Power and Signal Control (Issue 1).pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 11, 20161UL 2988Outline of Investigation for Universal Hybrid Power and Signal/ControlCablesIssue Number: 1May 11, 2016Summary of TopicsThis is the first issue of the Outline of Investigation
2、 for Universal HybridPower and Signal/Control Cables, UL 2988, covering multi-conductor,nonintegrally jacketed or metal armored cable consisting of power unitsand control/signal/communication units.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outlin
3、e of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUC
4、TION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 11, 2016UL 29882No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Units of Measurement .53 Undated References 6CONSTRUCTION4 Materials .65 Gene
5、ral 66 Power Unit NEC Type .67 Power Unit Non-NEC Type .77.1 General .77.2 Fillers .97.3 Shield(s) .97.4 Jacket .97.5 Thicknesses 118 Signal/Control Unit .128.1 General 128.2 Material and application 129 Assembly .139.1 Parallel construction .139.2 Round construction 139.3 Armor 13PERFORMANCE10 Gene
6、ral 1410.1 Power units 1410.2 Signal/control units .1410.3 Overall construction 1411 Test for Durability of Ink Printing 1512 Vertical Flame Test .1513 Jacket Thickness .1514 Physical Properties .1615 Heat Shock Test of Thermoplastic Jacket 1616 Cold Bend Test .1717 Deformation Test of Overall Therm
7、oplastic or XL Jacket .1818 Dielectric Voltage-Withstand Test .1819 Test of Zinc Coating on Steel Armor 1920 Tension Test .20OPTIONAL TESTS21 Vertical-Tray Flame Test .2022 Limited Smoke .2023 Cold-Impact Test .2024 Crushing Test Cable Marked for Direct Burial 2125 Sunlight-Resistance Test 2226 Cabl
8、es Marked ER .22MAY 11, 2016 UL 2988 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL26.1 General .2226.2 Impact Test 2226.3 Crushing test 24MARKINGS27 Information on or in the Cable 2528 Information on the Tag, Reel, or Carton .2629 Copper-C
9、lad Aluminum 2730 Aluminum 2731 Responsibility for the Insulated Conductors 2831.1 No identification needed 2831.2 Only factory identification needed 2831.3 Organization and factory identification needed .28MAY 11, 2016UL 29884UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIB
10、UTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover multi-conductor, nonintegrally jacketed or metal armored cable consistingof power units and control/signal/communication units. Each of the units is laid parallel to the next unit, orthe jacketed units may be twisted und
11、er an overall jacket or metallic armor. The cable is intended for usewith specific equipment and devices that are required to be powered and controlled from the same cable,such as (but not limited to) lighting and sound units in theaters, and ductless air conditioning systems.The installation of thi
12、s hybrid cable is intended to be in accordance with the National Electrical Code,ANSI/NFPA 70, in addition to any applicable building codes.1.2 The conductors for the power units in these cables are either unmarked, jacketed cables described inthe NEC, or use insulated conductors described in the NE
13、C. Jacketed cables used for both the powerunits and the control units are described in Sections68.Cables are marked with the temperature, voltage and other optional ratings.Cables for direct burial are so marked.Cables may be marked sun res or sunlight resistant.Cables that are marked oil resistant
14、II have a jacket that is suitable for exposure to oil attemperatures not in excess of 75C (167F).Cables that are marked oil resistant I have a jacket that is suitable for exposure to oil attemperatures not in excess of 60C (140F).Each insulated conductor that is oil resistant II, oil resistant I, VW
15、-1, gasoline-resistant, or hasanother individual conductor use is individually so marked.2 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.MAY 11, 2016 UL 2988 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR F
16、URTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Undated References3.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.3.2 Wherever the designation UL 1581 is used
17、in this cable outline, reference is to be made to thedesignated part(s) of the Reference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581.Whenever the designation UL 2556 is used in this outline, reference is to be made to the designatedparts of the Wire and Cable Test Methods, UL
18、2556.CONSTRUCTION4 Materials4.1 Only materials that are acceptable for the particular use shall be employed in a cable.4.2 Each material used in a cable shall be compatible with all of the other materials used in the cable.5 General5.1 Hybrid cable shall comply in all respects with the applicable re
19、quirements for construction details, testperformance, and markings.6 Power Unit NEC Type6.1 Each power unit shall consist of one of the following cable types shown in Table 6.1, as described inthe National Electrical Code (NEC) and complying with the indicated standard. The power unit NEC typeshall
20、not be surface printed with the markings required in the applicable standard in Table 6.1.Table 6.1Power unit cable typesType Standard Type designation Maximum temperature andvoltageFlexible Cord UL 62 SJT, SJ, SJE, suffixed by W,O and/or OO as required forthe application.105C, 300VST, S, SE, suffix
21、ed by W, Oand/or OO as required for theapplication.105C, 600VNonmetallic-Sheathed Cable UL 719 NM, NM-B 90C, 600VPower and Control Tray Cable UL 1277 TC 90C, 600VMAY 11, 2016UL 29886UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7 Power Unit
22、Non-NEC Type7.1 General7.1.1 As an option, the power unit shall consist of one of the insulated conductor types shown in Table7.1, complying with the indicated standard. Two to four insulated conductors may be laid parallel or maybe twisted. Five or more conductors shall be twisted. The length of la
23、y of the twisted conductors shallcomply with the requirements in Table 7.2. The insulated conductors shall be covered with an overalljacket complying with the requirements in 7.3.Table 7.1Insulated conductor types and ratingsType Standard Type designation Maximum temperature and voltageratingFluorop
24、olymer Insulated Wire UL 83 FEP and FEPB 200C (392F) dry 600 V specialapplicationsor90C (194F) dry 600 VThermoset Insulated Wire UL 44 RHH 90C (194F) dry 600 Vor2kVUL 44 SA 200C (392F) dry 600 Vspecial applications or90C (194F) dry 600 VUL 44 RHW-2 90C (194F) wet or dry600Vor2kVUL 44 RHW 75C (167F)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT29882016OUTLINEOFINVESTIGATIONFORUNIVERSALHYBRIDPOWERANDSIGNALCONTROLISSUE1PDF

链接地址:http://www.mydoc123.com/p-1069384.html