1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 20, 20161UL 2930Outline of Investigation for Cord-and-Plug-Connected Health Care FacilityOutlet AssembliesIssue Number: 1October 20, 2016Summary of TopicsThis first issue of the Outline o
2、f Investigation for Cord-and-Plug-Connected Health Care Facility Outlet Assemblies, UL 2930, coversassemblies of multiple receptacle outlets that are intended for connectionof medical equipment. Medical equipment is typically intended for use ina General Patient Care (Category 2) Space or Critical P
3、atient Care(Category 1) Space, including Patient Care Vicinities equipped with PatientEquipment Grounding Points. Receptacles so located must have adual-fed grounding capability in compliance with NEC Article 517.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectroni
4、c copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZE
5、D FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 20, 2016UL 29302No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 General 62.1 Use .62.2 Components .72.3 Units of me
6、asurement .72.4 Undated references .73 Glossary .7CONSTRUCTION4 General 95 Enclosures 105.1 General 105.2 Metallic .106 Mechanical Assembly 117 Accessibility of Live Parts .118 Mounting Means .139 Corrosion Protection .1310 Insulating Materials .1311 Power-Supply Cord .1411.1 General .1412 Strain Re
7、lief 1413 Receptacles 1513.1 General .1513.2 Receptacle covers 1514 Supplementary Protection Device .1615 Live Parts 1616 Internal Wiring 1617 Physical protection of conductors .1718 Spacings 1819 Printed-Wiring Boards .1920 Grounding .1920.1 General .1920.2 Bonding .2020.3 Patient equipment groundi
8、ng terminal .2120.4 Patient equipment grounding conductor .22PERFORMANCE21 General 2222 Temperature Test .2223 Dielectric Voltage-Withstand Test .2424 Leakage Current Test .2525 Grounding Continuity Test .2726 Fault Current Test 2826.1 General .2826.2 Calibration of test circuits 2827 Overcurrent Te
9、st 29OCTOBER 20, 2016 UL 2930 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL28 Mounting Hole Barrier Tests .3028.1 General .3028.2 Mounting hole barrier impact test .3028.3 Mounting hole barrier probe test .3129 Strain Relief Test .3230 Enc
10、losure Tests 3330.1 General .3330.2 Drop impact test .3430.3 Steel sphere impact test 3431 Crushing Test 3832 Enclosure Integrity Test .3833 Adequacy of Mounting Test 4334 Receptacle Outlet Cover Test 4435 Marking Durability .4536 Permanence of Cord Tag Test .4536.1 General .4536.2 Conditioning .463
11、6.3 Test method .46RATINGS37 Details .46MARKINGS38 Details .47INSTRUCTIONS39 General 49APPENDIX AStandards for ComponentsA1OCTOBER 20, 2016UL 29304UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover
12、indoor-use cord-and-plug-connected Health Care Facility receptacle outletassemblies (HCOA) rated 250 V AC or less and 20 Amperes or less. HCOA are for use as a movablepower supply connection for cord-and-plug-connected medical electrical utilization equipment inaccordance with the National Electric
13、Code, NFPA 70, Article 517 Health Care Facilities, and with NFPA99, Health Care Facilities Code, for use in Category 2 (General Patient Care) Spaces or Category 1(Critical Patient Care) Spaces, including Patient Care Vicinities equipped with Patient EquipmentGrounding Points.1.2 HCOAs are intended f
14、or use with equipment complying with applicable requirements of the:a) Standard for Medical Electrical Equipment, Part 1: General Requirements, UL 60601-1;b) Medical electrical equipment Part 1: General requirements for basic safety and essentialperformance, IEC 60601-1; andc) Medical Electrical Equ
15、ipment Part 1-2: General Requirements for basic safety andessential performance Collateral standard: Electromagnetic disturbances Requirements andtests, ANSI/AAMI 60601-1-2.1.3 These requirements cover HCOA consisting of an ANSI/NEMA WD 6-configuration Hospital Gradeattachment plug and a length of n
16、on-detachable flexible cord terminated in an enclosure in which aremounted ANSI/NEMA WD 6-configuration Hospital Grade individual receptacle outlets (duplex or single)which are connected conductively to an integral patient equipment grounding terminal or jack provided foruser connection of a discret
17、e grounding path conductor to Patient Equipment Grounding Points, installedin the Patient Care Vicinities of a Health Care Facility.1.4 An HCOA is not intended for Home Health Care Use.1.5 These requirements do not cover cord-connected, Relocatable Power Taps (RPT) intended only forindoor use as a t
18、emporary extension of a grounding alternating-current branch circuit for general use,covered by the Standard for Relocatable Power Taps, UL 1363. RPT are not suitable for use in Category2 (General Patient Care) Spaces or Category 1 (Critical Patient Care) Spaces or Patient Care Vicinities.1.6 These
19、requirements do not cover cord-connected, Special Purpose Relocatable Power Taps(SPRPT); covered by the Outline of Investigation for Special Purpose Relocatable Power Taps, UL 1363A.SPRPT are power distribution components intended to supply power to plug-connected components of amovable equipment as
20、semblies that are rack, table, or pedestal-mounted. SPRPT are intended for use ascomponents of complete equipment submitted for investigation rather than for direct separate installationin the field. The SPRPT shall be an integral part of the equipment assembly and permanently attached tothe equipme
21、nt assembly only by those qualified to assemble medical electrical equipment systemscompliant with Medical electrical equipment Part 1: General requirements for basic safety and essentialperformance, IEC 60601-1. SPRPT are not suitable for use in Patient Care Vicinities.OCTOBER 20, 2016 UL 2930 5UL
22、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL1.7 These requirements do not cover cord-connected, Furniture Power Distribution Units (FPDU),intended for indoor use that provide power for and are intended to be installed in furnishings. FPDU are
23、covered by the Standard for Furniture Power Distribution Units, UL 962A.2 General2.1 Use2.1.1 A HCOA is intended to be connected temporarily to a permanently installed branch circuit HospitalGrade receptacle outlet and to patient equipment grounding points installed in the patient care spaces ofa He
24、alth Care Facility.2.1.2 A HCOA is intended for cord-and-plug connection of medical utilization equipment that has beenauthorized by the Health Care Facility in which the HCOA is deployed and that has been verified as havingtouch and leakage current suitably low for patient care use.2.1.3 A HCOA is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT29302016ULOUTLINEFORINVESTIGATIONCORDANDPLUGCONNECTEDHEALTHCAREFACILITYOUTLETASSEMBLIESISSUE1PDF

链接地址:http://www.mydoc123.com/p-1069381.html