UL SUBJECT 2880-2014 UL Outline of Investigation for Limited-Power Wire and Cable Using Copper-Clad Aluminum Conductors (Issue 1)《使用铜包铝导线对有限功率电线和电缆的UL调查大纲 (议题1)》.pdf
《UL SUBJECT 2880-2014 UL Outline of Investigation for Limited-Power Wire and Cable Using Copper-Clad Aluminum Conductors (Issue 1)《使用铜包铝导线对有限功率电线和电缆的UL调查大纲 (议题1)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2880-2014 UL Outline of Investigation for Limited-Power Wire and Cable Using Copper-Clad Aluminum Conductors (Issue 1)《使用铜包铝导线对有限功率电线和电缆的UL调查大纲 (议题1)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 10, 20141UL 2880Outline of Investigation for Limited-Power Wire and Cable UsingCopper-Clad Aluminum ConductorsIssue Number: 1October 10, 2014Summary of TopicsEditorial revision to correct
2、 aged tensile strength in 11.2.2 from 59 to 50percent.COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULOCTOBER 10, 2014UL 28802No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
3、EPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .44 References .4CONSTRUCTION5 Assembly 56 Conductors .57 Insulation 58 Overall Jacket 5MARKING9 On the Cable .510 On the Tag, Reel, or Carton .6TEST PROGRAM11 Details 711.1 Dimens
4、ions .711.2 Physical properties 711.3 Dielectric withstand and breakdown 811.4 Horizontal flame test (optional) 811.5 FT2 flame test (optional) .811.6 FT1 flame test (optional) .811.7 Cable flame test (optional) 811.8 VW-1 flame test (optional) 911.9 Durability of ink-print test .9MANUFACTURING AND
5、PRODUCTION LINE TESTS12 Spark Test 9OCTOBER 10, 2014 UL 2880 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline covers single-conductor and multiple-conductor; integrally jacketed, jacketed andunjacketed; flat
6、 parallel or round multiple-conductor wires and cables utilizing copper-clad aluminum(CCA) conductors. Wires and cables are rated either 0.5mA/15W maximum or 30V/15W maximum. Themaximum temperature rating of the wire or cable shall not exceed 80C (176F). The wires and cablesare suitable for installa
7、tion in dry locations only.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirements for that component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required
8、 in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with its recognized rating established for the intendedconditions of use.2.4 Specific components are incomplete in construction
9、features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the
10、 requirement. Values in parentheses are explanatory orapproximate information.4 References4.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.4.2 Wherever the designation UL 1581
11、 is used in this standard, reference is to be made to thedesignated parts of the Reference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581.Whenever the designation UL 2556 is used in this standard, reference it to be made to the designatedparts of the Standard for Wire and Cable T
12、est Methods, UL 2556.4.3 Wherever CCA is used in this standard, it refers to Copper-Clad Aluminum.OCTOBER 10, 2014UL 28804UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONSTRUCTION5 Assembly5.1 The cable shall consist of a single- or multipl
13、e-conductor insulated CCA conductor(s) without a jacket,or one or more insulated CCA conductors cabled or laid together under an overall nonintegral or integraljacket. The cable may contain any number of coverings, fillers, binders, and/or shields under the jacket.6 Conductors6.1 Conductors shall be
14、 CCA and shall conform to the tensile strength and elongation, resistivity andcopper thickness as indicated in the Standard Specification for Copper-Clad Aluminum Wire, ASTM B566.The conductor size shall be between 36 AWG and 13 AWG inclusive. The annealed conductors shallcontain nominal 10 or 15 pe
15、rcent copper by volume.7 Insulation7.1 The insulation shall be thermoplastic or thermoset.8 Overall Jacket8.1 The overall jacket shall be thermoplastic or thermoset.MARKING9 On the Cable9.1 The surface marking on the insulated conductors shall consist of a series of dots and dashes asshown below con
16、tinuously along the length of the outer surface to indicate the presence of a copper-cladaluminum conductor._._._._._._._._._._._._._9.2 As an alternate to the series of dots and dashes indicated in 9.1, CCA may be surface printed onthe wire at intervals not to exceed 24 inches (610 mm) if the dimen
17、sions of the wire are such that theprinting is legible.9.3 Other markings such as wire size, number of conductors or similar data in compliance with this outlinemay be surface printed in parallel with the_._._._, integrated with the CCA marking, or on the outersurface of the wire or cable when they
18、are not confusing or misleading.OCTOBER 10, 2014 UL 2880 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10 On the Tag, Reel, or Carton10.1 The tag markings shall be as follows:a) The organization responsible for the product.b) The model numb
19、er or catalog number.c) The maximum temperature rating.d) Either For use at 0.5mA/15W maximum or For use at 30V/15W maximum.e) Either Copper-clad aluminum conductors or CCA conductors.f) The percentage of copper, by area.g) Insulation material and thickness.h) Jacket material and thickness (if prese
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT28802014ULOUTLINEOFINVESTIGATIONFORLIMITEDPOWERWIREANDCABLEUSINGCOPPERCLADALUMINUMCONDUCTORSISSUE1

链接地址:http://www.mydoc123.com/p-1069367.html