1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJULY 19, 20161UL 2877Outline of Investigation for Power Supplies, Medium VoltageIssue Number: 2July 19, 2016Summary of TopicsThis second issue of the Outline of Investigation for Power Supplies,M
2、edium Voltage, UL 2877, covers requirements for power supplies withinput voltage ratings greater than 1000 V, to 15 kV.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Inve
3、stigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJULY 19, 2016UL 28772No Te
4、xt on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Glossary .53 Components 64 Units of Measurement and Undated References 65 Normal and Special Service Conditions 65.1 Normal service conditions .65.2
5、 Special service conditions .7CONSTRUCTION6 General 77 Enclosures .78 Grounding and Bonding 119 Protective Devices .1210 Isolating Means .1311 Interlocking 1311.1 Isolating means interlocks .1311.2 Drawout element interlocks 1311.3 Door interlocks .1512 Automatic Restarting 1513 Wiring and Connectio
6、ns .1614 Insulating Materials .1914.1 General .1914.2 Isolation of semiconductor devices .2015 Field Installed Accessories .2016 Spacings 2016.1 General .2016.2 Circuits of 1000 V or less to ground 2216.3 Spacings to SELV circuits .2316.4 Spacings for printed wiring boards in accordance with the Sta
7、ndard for InsulationCoordination Including Clearances and Creepage Distances for Electrical Equipment, UL840 .2317 Current Carrying Parts 2518 SELV Circuits 2618.1 General requirements .2618.2 Voltages under normal conditions 2618.3 Voltages under single fault conditions .2618.4 Separation from haza
8、rdous voltages 2619 Modular Constructions .27PERFORMANCE20 General 2721 Temperature Test .2821.1 General .2821.2 Test conditions .3022 Overload Test 3123 Overvoltage Test .31JULY 19, 2016 UL 2877 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM
9、UL24 Mechanical Tests .3225 Output Short Circuit Test 3226 Dielectric Voltage-Withstand Tests (Power Frequency and Impulse) 3426.1 Power-frequency voltage withstand test .3426.2 Impulse withstand tests .3627 Switching Capacity Test - Isolating Means .3827.1 Non-interlocked isolating means 3827.2 Int
10、erlocked isolating means 3928 Mechanical Tests of Viewing Panes .3929 Rod Entry Test .3930 Enclosure Ground Integrity Test 4031 Driven Rain Test 4032 Shutter Integrity Test 4033 Inoperative Blower Motor Test 4034 Clogged Filter Test 4035 Breakdown of Components Test .4036 Verification of SELV Circui
11、ts Test .42RATING37 General 42MARKING38 General 4339 General Markings for Power Supplies .4340 Conditional Markings 4441 Additional Equipment Information .46JULY 19, 2016UL 28774UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Sco
12、pe1.1 These requirements cover power supplies having ac or dc input voltage ratings above 1000 V, up to15 kV, and ac or dc output voltage ratings up to 15 kV.1.2 These power supplies may have one or more circuits that are classified as safety extra low voltage(SELV).1.3 These requirements cover equi
13、pment intended for use in ordinary locations in accordance with theNational Electrical Code.1.4 These requirements also cover open type, or partially enclosed power supplies intended to beinstalled in equipment where the overall assembly is investigated using this outline of investigation, oranother
14、 applicable standard for medium voltage equipment.2 Glossary2.1 The definitions in UL 347 are applicable. Where definitions in this outline conflict with definitions inUL 347, the definitions in this outline take precedence.2.2 SELV CIRCUIT A secondary circuit with voltages that do not exceed a safe
15、 value under normaloperating conditions and single fault conditions.NOTE: The voltage limits for SELV circuits are specified in 18.1.2.3 BASIC INSULATION Insulation to provide protection against electric shock.2.4 DOUBLE INSULATION Insulation consisting of basic insulation, plus supplementary insula
16、tion.2.5 MODULAR CONSTRUCTION POWER SUPPLIES Power supplies using multiple modules, eachwith low voltage input and output voltage ratings. Refer to 19.1.2.6 REINFORCED INSULATION A single insulation that provides equivalent protection against electricshock as double insulation.2.7 REMOVABLE MODULE A
17、 portion of a modular construction power supply that is capable of beingremoved for replacement without opening the power supply enclosure or disassembly of parts other thanthose within the removable portion.2.8 STANDBY CURRENT The current that flows in the input circuit of a power supply when the p
18、owersupply is connected to a source of rated voltage, but is not delivering load current.2.9 SUPPLEMENTARY INSULATION Insulation that is independent of, and in addition to, basicinsulation, that provides the same level of insulation as the basic insulation, should the basic insulationfail.JULY 19, 2
19、016 UL 2877 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Components3.1 A component of a product covered by this Outline shall comply with the requirements for thatcomponent and shall be used in accordance with its recognized rating and o
20、ther limitations of use. SeeAppendix A for a list of standards covering components used in the products covered by this outline. Acomponent is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduc
21、t covered by this outline, orb) Is superseded by a requirement in this outline.3.2 Components that provide isolation between medium voltage circuits and low voltage circuits (such astransformers, optical isolators, and the like) shall be provided with sufficient insulation to withstand therated powe
22、r frequency dielectric voltage and rated impulse voltage between the circuits.3.3 Components that provide isolation between medium voltage circuits and SELV circuits shall beprovided with double or reinforced insulation, and the insulation shall be sufficient to withstand 160% ofthe rated power freq
23、uency dielectric voltage and 160% of the rated impulse voltage between the circuits.4 Units of Measurement and Undated References4.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4.2 Any undated reference to a code or standard
24、appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Normal and Special Service Conditions5.1 Normal service conditions5.1.1 Apparatus within the scope of this standard shall be capable of operation within its performancespec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT28772016OUTLINEOFINVESTIGATIONFORPOWERSUPPLIESMEDIUMVOLTAGEISSUE2 压电 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069365.html