1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 19, 20171UL 2726Outline of Investigation for Battery Lead WireIssue Number: 2September 19, 2017Summary of TopicsThis is the second issue of the Outline of Investigation for Battery Lead
2、Wire. This issue expands the size range of acceptable conductors to10 mm2 210 mm2(10 AWG 400 kcmil).ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all c
3、opyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2017 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 19, 2017UL 27262No Text on This Pag
4、eUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Units of Measurement .43 Components 44 Undated References 5CONSTRUCTION5 Materials and Workmanship 56 General 56.1 Assembly 56.2 Conductors 56.3 Insulation 6PERFO
5、RMANCE7 General 68 Manufacturing and Production Test 11MARKINGS9 General .1110 Tag, Reel or Carton Markings 11SEPTEMBER 19, 2017 UL 2726 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline covers the requiremen
6、ts for single conductor battery leads for use in the Standard forIndustrial Trucks, Internal Combustion Engine-Powered, UL 558, and the Standard forElectric-Battery-Powered Industrial Trucks, UL 583. The wire is rated 60, 75, 90, or 105C and 30, 48, 60,90 or 150 V DC.2 Units of Measurement2.1 Values
7、 stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.2.2 Conductor sizes are stated in both AWG and mm2. These values are not considered equivalent.3 Components3.1 Except as indicated in 3.2, a component (including gaskets and polymeric mat
8、erials) of a productcovered by this outline of investigation shall comply with the requirements for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered
9、 by this outline of investigation, orb) Is superseded by a requirement in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricted in performan
10、ce capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.SEPTEMBER 19, 2017UL 27264UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUT
11、ION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 Materials and Workmanship5.1 Only materials t
12、hat are acceptable for the particular use shall be employed in a wire. Wires shall bemade and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.5.2 Each material used in a wire shall be compatible with all of the other materials used in th
13、e wire.6 General6.1 Assembly6.1.1 These wires consist of a single insulated conductor.6.2 Conductors6.2.1 Conductors shall be 10 mm2 210 mm2or 10 AWG 400 kcmil in size and shall comply with theminimum area as shown in Table 6.1 and Table 6.2, as applicable. Conductors shall consist of copper inaccor
14、dance with Standard Specification for Soft or Annealed Copper Wire, ASTM B3, StandardSpecification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes, ASTM B33, StandardSpecification for Silver-Coated Soft or Annealed Copper Wire, ASTM B298, or Standard Specification forNickel-Coate
15、d Soft or Annealed Copper Wire, ASTM B355. The conductor stranding is not defined , butshall be judged based on compliance of the wire with the test program in Section 7.Table 6.1Conductor area, metric conductorsMetric conductor size, mm2Minimum conductor area, mm210 9.313 12.116 14.919 18.325 24.13
16、2 31.135 34.040 38.150 48.362 59.870 67.581 77.695 91.0103 98.5120 114.8210 200.6SEPTEMBER 19, 2017 UL 2726 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 6.2Conductor area, AWG conductorsAWG Size Minimum conductor Area, cmil10 9,3438
17、14,8106 24,5384 37,3602 62,4501 77,7901/0 98,9802/0 125,1003/0 158,6004/0 205,500400 382,0006.3 Insulation6.3.1 The insulation material shall be one described in the Tables in Specific Materials, Section 50 of theReference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581, suitable
18、for thetemperature rating of the wire. Regardless of what is noted in the Table, the minimum unaged tensilestrength value shall be 1200 psi (8.27 MPa).6.3.2 The insulation shall be solid in form and shall be extruded directly over the conductor.6.3.3 The average insulation thickness shall not be les
19、s than 0.060 inch (1.5 mm) for a conductor sizebetween 10 AWG and 2 AWG and shall not be less than 0.080 inch (2.0 mm) for a wire larger than orequal to 1 AWG. The average insulation thickness for metric sized wires shall not be less than 0.060 inch(1.5 mm) for a conductor size between 10 mm2and 32
20、mm2shall not be less than 0.080 inch (2.0 mm)for a wire larger than or equal to than 40 mm2.PERFORMANCE7 General7.1 The following tests shall be performed in accordance with, and comply with the requirements in theStandard for Wire and Cable Test Methods, UL 2556, unless otherwise specified below.7.
21、1.1 Detailed Examination To confirm that the construction of the wire meets the requirementsdescribed in CONSTRUCTION.7.1.2 Physical Properties of Insulation and Jacket Values for the materials as stated in the applicabletable in Specific Materials, Section 50 of the Reference Standard for Electrica
22、l Wires, Cables, and FlexibleCords, UL 1581. Regardless of what is noted in the table, minimum unaged tensile strength shall not beless than 1200 psi (8.27 MPa).SEPTEMBER 19, 2017UL 27266UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.1.3 Co
23、nductor Corrosion (uncoated copper only) The aging time and temperature shall be the sameas used for Physical Properties of Insulation and Jacket described in 7.1.2. Upon examination of theconductor after removal of the insulation, there shall be no evidence of pitting or corrosion of theconductor.7
24、.1.4 Heat Shock (thermoplastic insulation only) The specimens are to be conditioned for one hour atthe temperature shown in Table 7.1 based on material. The specimens shall be wrapped in a U-bendaround the mandrel. The mandrel used shall be two times (2X) the diameter of the insulated wire. Uponvisu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT27262017ULOUTLINEFORINVESTIGATIONBATTERYLEADWIREISSUE2 蓄电池 引线 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069331.html