1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAugust 14, 20091SUBJECT 2726OUTLINE OF INVESTIGATIONFORBATTERY LEAD WIREIssue Number: 1August 14, 2009Summary of TopicsThis is the first issue of the Outline of Investigation for Battery Lead Wir
2、e.The effective date for this issue is November 1, 2011.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2009
3、 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 14, 2009SUBJECT 27262No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINT
4、RODUCTION1 Scope .42 Units of Measurement .43 Components 44 Undated References 5CONSTRUCTION5 Materials and Workmanship 56 General 56.1 Assembly 56.2 Conductors 56.3 Insulation 6PERFORMANCE7 General 68 Manufacturing and production test .11MARKINGS9 General .1110 Tag, Reel or Carton Markings 11AUGUST
5、 14, 2009 SUBJECT 2726 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 ScopeSection 1 effective November 1, 20111.1 This outline covers the requirements for single conductor battery leads for use in the Standard forIndustrial Tr
6、ucks, Internal Combustion Engine Powered, UL 558, and Electric Battery Powered IndustrialTrucks, UL 583. The wire is rated 60, 75, 90, or 105C (140, 167, 194, or 221 F) and 30, 48, 60, 90 or150 Vdc.2 Units of MeasurementSection 2 effective November 1, 20112.1 In addition to being stated in the inch/
7、pound units that are customary in the USA, each of therequirements in this outline is also stated in units that make the requirement conveniently usable incountries employing the metric system (practical SI). Equivalent although not necessarily exactlyidentical results are to be expected from applyi
8、ng a requirement in USA or metric terms. Equipmentcalibrated in metric units is to be used when a requirement is applied in metric terms.3 ComponentsSection 3 effective November 1, 20113.1 Except as indicated in 3.2, a component (including gaskets and polymeric materials) of a productcovered by this
9、 outline of investigation shall comply with the requirements for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline of investigation,
10、orb) Is superseded by a requirement in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are
11、 intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.AUGUST 14, 2009SUBJECT 27264UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 U
12、ndated ReferencesSection 4 effective November 1, 20114.1 Any undated reference to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 Materials and WorkmanshipSection 5 effecti
13、ve November 1, 20115.1 Only materials that are acceptable for the particular use shall be employed in a wire. Wires shall bemade and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.5.2 Each material used in a wire shall be compatible wit
14、h all of the other materials used in the wire.6 GeneralSection 6 effective November 1, 20116.1 Assembly6.1.1 These wires consist of a single insulated conductor.6.2 Conductors6.2.1 Conductors shall be 13 mm2 103 mm2(6 AWG 4/0 AWG) in size and shall comply with theminimum area as shown in Table 1 and
15、 Table 2, as applicable. Conductors shall consist of copper inaccordance with Standard Specification for Soft or Annealed Copper Wire, ASTM B3, StandardSpecification for Tinned Soft or Annealed Copper Wire for Electrical Purposes, ASTM B33, StandardSpecification for Silver-Coated Soft or Annealed Co
16、pper Wire, ASTM B298, or Standard Specification forNickel-Coated Soft or Annealed Copper Wire, ASTM B355. The conductor stranding is not defined , butshall be judged based on compliance of the wire with the test program in Section 7.Table 1Conductor area, metric conductorsMetric conductor size, mm2M
17、inimum conductor area, mm213 12.119 18.332 31.140 38.150 48.362 59.881 77.6103 98.5AUGUST 14, 2009 SUBJECT 2726 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 2Conductor area, AWG conductorsAWG Size Minimum conductor Area, cmil6 24,538
18、4 37,3602 62,4501 77,7901/0 98,9802/0 125,1003/0 158,6004/0 205,5006.3 Insulation6.3.1 The insulation material shall be one described in the Tables in Section 50 of the ReferenceStandard for Electrical Wires, Cables, and Flexible Cords, UL 1581, suitable for the temperature rating ofthe wire. Regard
19、less of what is noted in the Table, the minimum unaged tensile strength value shall be1200 psi (8.27 MPa).6.3.2 The insulation shall be solid in form and shall be extruded directly over the conductor.6.3.3 The average insulation thickness shall not be less than 0.060 inch (1.5 mm) for a wire smaller
20、 thanor equal to 2 AWG and shall not be less than 0.080 inch (2.0 mm) for a wire larger than or equal to 1AWG. The average insulation thickness for metric sized wires shall not be less than 1.5 mm (0.060 inch)for a wire less than or equal to 32 mm2and shall not be less than 2.0 mm (0.080 inch) for a
21、 wire largerthan or equal to than 40 mm2.PERFORMANCE7 GeneralSection 7 effective November 11, 20117.1 The following tests shall be performed in accordance with, and comply with the requirements ofReference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581, unless otherwise specified
22、below.7.1.1 Detailed Examination To confirm that the construction of the wire meets the requirementsdescribed in CONSTRUCTION.7.1.2 Physical Properties of Insulation and Jacket Values for the materials as stated in the applicabletable in Section 50 of the Reference Standard for Electrical Wires, Cab
23、les, and Flexible Cords, UL 1581.Regardless of what is noted in the table, minimum unaged tensile strength 1200 psi (8.27 MPa).7.1.3 Conductor Corrosion (uncoated copper only) The aging time and temperature shall be the sameas used for Physical Properties of Insulation and Jacket described in 7.1.2.
24、 Upon examination of theconductor after removal of the insulation, there shall be no evidence of pitting or corrosion of theconductor.AUGUST 14, 2009SUBJECT 27266UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.1.4 Heat Shock (thermoplastic i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT27262009OUTLINEOFINVESTIGATIONFORBATTERYLEADWIREISSUE1 蓄电池 引线 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069330.html