《UL SUBJECT 2436-2006 SUBJECT 2436 OUTLINE OF INVESTIGATION FOR SPILL CONTAINMENT FOR STATIONARY LEAD ACID BATTERY SYSTEMS (Issue 1)《第2436号主题 固定式铅酸电池系统用溅溢围栏调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2436-2006 SUBJECT 2436 OUTLINE OF INVESTIGATION FOR SPILL CONTAINMENT FOR STATIONARY LEAD ACID BATTERY SYSTEMS (Issue 1)《第2436号主题 固定式铅酸电池系统用溅溢围栏调查大纲 发布编号 1》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJuly 31, 20061SUBJECT 2436OUTLINE OF INVESTIGATIONFORSPILL CONTAINMENT FOR STATIONARY LEAD ACID BATTERY SYSTEMSIssue Number: 1JULY 31, 2006Summary of TopicsThis is the first issue of the Outline
2、of Investigation for Spill Containmentfor Stationary Lead Acid Battery Systems.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandards
3、InfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJULY 31, 2006SUBJECT 24362No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSI
4、ON FROM ULCONTENTSINTRODUCTION1 Scope .52 Units of Measurement .53 Components 54 References .65 Glossary .6CONSTRUCTION6 General 67 Materials .78 Electrolyte Absorption and Neutralization 79 Spill Containment .7PERFORMANCESYSTEM TESTS10 Leakage 711 Electrolyte Absorption 812 Neutralization Capabilit
5、y Estimate 8MATERIAL TESTS13 Penetration Resistance .914 Volume Change and Extraction of Soluble Material .1015 Air Oven Aging .1016 Immersion .1017 Rigid Plastic 1118 Flexural Strength .1119 Joint Strength 1120 Non-Rigid Plastic .1121 Tensile Strength and Elongation 1122 Tear Strength 1223 Seam Str
6、ength .1224 Tensile Impact 1225 Fire Resistance .12MARKINGS26 General 1327 Cautionary Markings 1328 Nameplate and Other Non-Cautionary Markings 13INSTRUCTIONS29 Installation .1330 Maintenance .1431 Neutralizing Pillows .14JULY 31, 2006 SUBJECT 2436 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
7、 REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPPENDIX AStandards for ComponentsA1JULY 31, 2006SUBJECT 24364UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover spill containment for stationa
8、ry lead-acid and similar acid electrolytebattery systems investigated for liquid tightness, level of electrolyte absorption, pH neutralizationcapability, and flame spread resistance.1.2 These systems are intended to provide a means of containment for hazardous material liquids in theevent of electro
9、lyte leakage from stationary lead-acid or similar acid electrolyte battery systems.2 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.3 Components3.1 Except as indicated in 3.2, a component of a value cover
10、ed by this outline of investigation shallcomply with the requirements for that component.3.2 A component need not comply with a specific requirement that:a) Involves a feature or characteristic no needed in the application of the component in thevalue covered by this outline of investigation, orb) I
11、s superseded by requirements in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intend
12、ed for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3.5 Components such as fittings, sealants, gaskets, etc. are to be investigated with respect to suitabilityfor use as part of the spill contain
13、ment system. Factors, which are to be considered when investigatingcomponents, are:a) Structural integrity;b) Resistance to aging;c) Resistance to corrosion;d) Resistance to deterioration from exposure to acids contained.JULY 31, 2006 SUBJECT 2436 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
14、REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.6 Test methods appropriate for investigation of the component under consideration will be utilized.4 References4.1 Any undated reference to a code or standard appearing in the requirements of this Outline ofInvestigation shall be interpreted as
15、 referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this outline the following definitions apply.5.1.1 ELASTOMER Flexible materials such as rubber or synthetic rubber materials utilized forgaskets, seals and liner materials.5.1.2 FIELD ENGINEERED SYSTEMS Spill
16、containment systems that are essentially constructed atthe installation site from various components. Major seams and welds may be constructed at theinstallation site.5.1.3 NON-RIGID PLASTIC Plastic which is flexible in physical property, typically made fromthermoplastic resin having the property of
17、 softening or fusing when heated and of hardening andbecoming rigid again when cooled .5.1.4 PRE-ENGINEERED SYSTEMS Spill containment systems that are essentially complete whenshipped from the factory with all major seams and welds completed under controlled conditions at thefactory.5.1.5 RIGID PLAS
18、TIC Plastic which is inflexible in physical property, typically made fromthermosetting resin capable of becoming permanently rigid when heated or cured.CONSTRUCTION6 General6.1 Pre-Engineered spill containment systems are shipped to the site with an installation manual and areintended for installati
19、on in accordance with the instructions in the installation manual.6.2 Installation of the spill containment system, whether a Pre-Engineered system or a Field Engineeredsystem, shall be conducted under the supervision of the containment system manufacturer followingaccepted installation practices.JU
20、LY 31, 2006SUBJECT 24366UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7 Materials7.1 Polymeric materials utilized in spill containment systems that may be in contact with electrolyte froma spill shall be resistant to deterioration of the mat
21、erials mechanical strength properties as a result ofexposure to the electrolyte. Compliance is determined by the tests in Rigid Plastic, Section 17 orNon-Rigid Plastic, Section 20, as applicable to the type of material. Testing is conducted on as-receivedsamples of the materials and on samples subje
22、cted to Immersion, Section 16, Air Oven Aging, Section15. Results obtained from testing conducted on the conditioned samples are compared to that of resultsobtained on the as-received samples.7.2 Materials that may be in contact with electrolyte from a spill shall be resistant to deterioration fromt
23、he electrolyte. Compliance shall be determined by the tests in Volume Change and Extraction of SolubleMaterial, Section 14.7.3 Materials employed as liners and other containment means in spill containment systems shall beresistant to penetration as determined by the tests in Penetration Resistance,
24、Section 13.7.4 Containment systems shall comply with a Class I rating for fire resistance (a critical radiant flux 0.45W/cm2) in accordance with the Life Safety Code, NPFA 101. Compliance is determined by subjecting thenon-metallic parts of the system to the tests in Fire Resistance, Section 25.8 El
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT24362006SUBJECT2436OUTLINEOFINVESTIGATIONFORSPILLCONTAINMENTFORSTATIONARYLEADACIDBATTERYSYSTEMSISSUE1

链接地址:http://www.mydoc123.com/p-1069283.html