《UL SUBJECT 2422-2006 Outline of Investigation for Ultraviolet Curing Equipment for Commercial Use (Issue 2)《商用紫外线固化设备调查大纲 发布编号 2》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2422-2006 Outline of Investigation for Ultraviolet Curing Equipment for Commercial Use (Issue 2)《商用紫外线固化设备调查大纲 发布编号 2》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMay 31, 20061SUBJECT 2422OUTLINE OF INVESTIGATIONFORULTRAVIOLET CURING EQUIPMENT FOR COMMERCIAL USEIssue Number: 2May 31, 2006Summary of TopicsThis second issue of the Outline of Investigation fo
2、r Ultraviolet CuringEquipment for Commercial Use, Subject 2422, is issued to replace thereference to UL 1020, the Standard for Thermal Cutoffs for Use inElectrical Appliances and Components, with reference to UL 60691, theStandard for Thermal-Links Requirements and Application Guide. UL1020 was with
3、drawn and superseded by UL 60691.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATOR
4、IES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 31, 2006SUBJECT 24222No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Compo
5、nents 53 Units of Measurement .64 References .65 Glossary .6CONSTRUCTION6 General 77 Frame and Enclosure 77.1 General .77.2 Lamp compartment 148 Assembly .159 Corrosion Protection .1510 Resistance of Components to Degradation from Ultraviolet Radiation .1511 Cord Connected Equipment 1611.1 General .
6、1611.2 Strain relief 1711.3 Push-back relief 1712 Live Parts 1813 Internal Wiring 1813.1 General .1813.2 Protection of wiring .1913.3 Splices and connections 1913.4 Interconnecting cord and cable 2013.5 Separation of circuits .2114 Electrical Insulation .2115 Thermal Insulation 2216 Overcurrent Prot
7、ection 2217 Transformer Overcurrent Protection .2218 Thermal Cutoffs 2319 Lampholders .2320 Spacings 2321 Grounding .2422 Switches .2423 Protection Against Injury to Persons 2523.1 General .2523.2 Exposure to ultraviolet radiation 2523.3 Medium- and high-pressure lamps 2524 Protective Eyewear .26PER
8、FORMANCE25 General 2626 Ultraviolet Irradiance Test 2627 Power Input Test .2728 Leakage Current 2729 Temperature Test .30MAY 31, 2006 SUBJECT 2422 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL30 Test Leakage Current as a Result of Moisture
9、 3431 Dielectric Voltage-Withstand Test .3432 Mechanical Endurance Test 3533 Ball Impact .3534 Abnormal Operation Test 3734.1 General .3734.2 Hot restrike test 3835 Strain Relief Test .3836 Push-Back Relief Test .3837 Stability 3838 Push Test 3939 Lamp Rupture Test .39MANUFACTURING AND PRODUCTION-LI
10、NE TESTS40 Production-Line Dielectric Voltage-Withstand Test 3941 Grounding and Polarization Continuity Tests .4141.1 Grounding continuity test 4141.2 Polarization continuity test .41RATINGS42 Details .41MARKINGS43 General 4244 Cautionary Markings 43INSTRUCTION MANUALS45 General 4446 Instructions Pe
11、rtaining to Risk of Fire, Electric Shock, or Injury to Persons .4547 Training Instructions .4748 Operating Instructions .4749 User-Maintenance Instructions .4850 Moving and Storage Instructions 48Appendix AStandards for ComponentsA1MAY 31, 2006SUBJECT 24224UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
12、FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover ultraviolet curing equipment rated at 240 V or less for professionalcommercial indoor use in a dedicated, isolated, or restricted area, accessed only by qualified professionaloperators.1.2 T
13、hese products are intended for use in accordance with the Federal Radiation Control for Health andSafety Act of 1968, the Federal Food, Drug and Cosmetic Act, and the Code of Federal Regulations, Part1040, 21 CFR, Chapter 1, Subchapter J, Radiological Health.1.3 These products are intended only for
14、use in a restricted access area, or an area which incorporatessuitable site protection to prevent unintended exposure of untrained or unqualified persons to ultravioletradiation. It is the responsibility of the designated parties at the final installation site to confirm that properinstallation, tra
15、ining and control means have been implemented.1.4 These products are intended to be operated only in the presence of qualified professional operatorswho have been trained on mandatory operation procedures for proper use of the equipment.1.5 The physiological effects of the ultraviolet radiation emit
16、ted by this equipment have not beenevaluated. The physiological effects of substances used in lamps employed in these products have notbeen evaluated. Compatibility of the curing equipment with materials and the physiological effects of anyby-products of the curing process have not been evaluated.1.
17、6 These requirements do not cover electric heating or drying equipment. Such equipment is covered inthe Standard for Electric Heating Appliances, UL 499, and Electrical Equipment for Laboratory Use: Part1: General Requirements, UL 61010A-1.2 Components2.1 Except as indicated in 2.2, a component of a
18、 product covered by this outline of investigation shallcomply with the requirements for that component. See Appendix A for a list of standards coveringcomponents generally used in the products covered by this outline of investigation.2.2 A component is not required to comply with a specific requirem
19、ent that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline of investigation, orb) Is superseded by a requirement in this outline of investigation.2.3 A component shall be used in accordance with its rating established for t
20、he intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those sp
21、ecific conditions.MAY 31, 2006 SUBJECT 2422 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Unless indicated otherwise all voltage and current values mentioned in this Outline of Investigationare root-mean-square (rm
22、s).3.2 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 References4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall beinterpreted as referring to the latest edition of that code
23、 or standard.5 Glossary5.1 For the purpose of this Outline of Investigation, the following definitions apply.5.2 CONTAINED ATMOSPHERIC ENERGY (CAE) The energy calculated as follows:CAE = 0.15 (PC PE) Vin which:PC is the contained pressure in atmospheres;PE is the external pressure in atmospheres; an
24、dV is the volume in cubic centimeters.5.3 CRITICAL FAILURE A failure of a component or circuit that results in a condition, such as a riskof fire, electric shock, or injury to persons.5.4 DEACTIVATED LAMP A lamp in the end-of-life failure mode, resulting from the depletion of thefilament emission ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT24222006OUTLINEOFINVESTIGATIONFORULTRAVIOLETCURINGEQUIPMENTFORCOMMERCIALUSEISSUE2 商用 紫外线 固化

链接地址:http://www.mydoc123.com/p-1069280.html