《UL SUBJECT 2419-2004 OUTLINE OF INVESTIGATION FOR ELECTRICALLY CONDUCTIVE CORROSION RESISTANT COMPOUNDS (Issue 1)《导电耐腐蚀化合物调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2419-2004 OUTLINE OF INVESTIGATION FOR ELECTRICALLY CONDUCTIVE CORROSION RESISTANT COMPOUNDS (Issue 1)《导电耐腐蚀化合物调查大纲 发布编号 1》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、May 7, 20041SUBJECT 2419OUTLINE OF INVESTIGATIONFORELECTRICALLY CONDUCTIVE CORROSION RESISTANT COMPOUNDSIssue Number: 1MAY 7, 2004Summary of TopicsThis is the First Issue of the Outline of Investigation for ElectricallyConductive Corrosion Resistant Compounds.The UL Foreword is no longer located wit
2、hin the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2004 UNDERWRITERS LABORATORIES INC.MAY 7, 2004SUBJECT 24192No Text on This PageCONTENTSINTRODUCTION1
3、 Scope .42 General 42.1 Units of Measurement .42.2 Undated References 43 Glossary .4CONSTRUCTION4 General 5PERFORMANCE5 Material Identification 56 Electrical Resistance Test 57 Corrosion Resistance Test .68 Compatibility with Different Insulation 68.1 Specimen preparation .68.2 Physical properties t
4、est 6MARKINGS9 General 7MAY 7, 2004 SUBJECT 2419 3INTRODUCTION1 Scope1.1 These requirements cover electrically conductive corrosion resistant compounds for use on thethreads of Rigid Metal Conduit (RMC) and Intermediate Metal Conduit (IMC). These compounds areintended to resist corrosion and provide
5、 electrical conductivity in accordance with Section 300.6(a) of theNational Electrical Code, NFPA 70-2002 when used in accordance with the manufacturerss installationinstructions.1.2 These compounds are not suitable for use on conduit intended for use in Hazardous Locations asdefined by the National
6、 Electrical Code, NFPA 70.1.3 In addition to the requirement as specified in this outline, these compounds are to be evaluated fortheir suitability with the specific conduit type used and the specific application.2 General2.1 Units of Measurement2.1.1 Values stated without parentheses are the requir
7、ement. Values in parentheses are explanatory orapproximate information.2.2 Undated References2.2.1 Any undated reference to a code or standard appearing in the requirements of this standard shallbe interpreted as referring to the latest edition of that code or standard.3 Glossary3.1 For the purposes
8、 of this outline, the following definitions apply.3.2 COMPOUND A combination of elements used to coat conduit threads that provides corrosionresistance and conductivity.3.3 INTERMEDIATE METAL CONDUIT Conduit that is for use as a metal raceway for the installationof wires and cables as defined in the
9、 Standard for Electrical Intermediate Metal Conduit Steel, UL 1242.3.4 RIGID METAL CONDUIT Conduit that is for use as a metal raceway for the installation of wires andcables as defined in the:a) Standard for Electrical Rigid Metal Conduit Steel, UL 6; andb) Standard for Electrical Rigid Metal Condui
10、t Aluminum, Red Brass, and Stainless Steel, UL6A.MAY 7, 2004SUBJECT 24194CONSTRUCTION4 General4.1 A compound shall be evaluated for its compatibility with the different types of wire insulation that areto be encountered in the conduit application.4.2 When a manufacturer specifies that a compound is
11、not suitable for a particular type of insulation, thelimitation shall be printed on the container used to package the compound. See Markings, Section 9.4.3 Compounds shall be subjected to the tests in Sections58.PERFORMANCE5 Material Identification5.1 An electrically conductive compound that is to b
12、e used on threads of conduit shall be subjected to theInfrared Spectroscopy (IR) tests specified in the Standard for Polymeric Materials Short Term PropertyEvaluations, UL 746A.6 Electrical Resistance Test6.1 The electrical resistance of the connection between adjacent sections of conduit joined by
13、a couplingshall not exceed 0.005 ohm. Tests are to be conducted first on three specimens that are not provided withthe corrosion-resistant compound on the threads. The tests are to be repeated on the same specimensthat are provided with the compound.6.2 The conduit is to be cut, threaded and joined
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT24192004OUTLINEOFINVESTIGATIONFORELECTRICALLYCONDUCTIVECORROSIONRESISTANTCOMPOUNDSISSUE1 导电

链接地址:http://www.mydoc123.com/p-1069279.html