UL SUBJECT 2265A-2004 OUTLINE OF INVESTIGATION FOR HAND-HELD OR HAND-TRANSPORTABLE FUEL CELL POWER UNITS WITH DISPOSABLE METHANOL FUEL CARTRIDGES FOR USE IN ORIGINAL EQUIPMENT MANU.pdf
《UL SUBJECT 2265A-2004 OUTLINE OF INVESTIGATION FOR HAND-HELD OR HAND-TRANSPORTABLE FUEL CELL POWER UNITS WITH DISPOSABLE METHANOL FUEL CARTRIDGES FOR USE IN ORIGINAL EQUIPMENT MANU.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2265A-2004 OUTLINE OF INVESTIGATION FOR HAND-HELD OR HAND-TRANSPORTABLE FUEL CELL POWER UNITS WITH DISPOSABLE METHANOL FUEL CARTRIDGES FOR USE IN ORIGINAL EQUIPMENT MANU.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、November 19, 20041SUBJECT 2265AOUTLINE OF INVESTIGATIONFORHAND-HELD OR HAND-TRANSPORTABLE FUEL CELL POWER UNITS WITHDISPOSABLE METHANOL FUEL CARTRIDGES FOR USE IN ORIGINALEQUIPMENT MANUFACTURERS INFORMATION TECHNOLOGYEQUIPMENTIssue Number: 1NOVEMBER 19, 2004Summary of TopicsThis is the first issue o
2、f the Outline of Investigation for Hand-Held orHand-Transportable Fuel Cell Power Units with Disposable Methanol FuelCartridges for Use in Original Equipment Manufacturers InformationTechnology Equipment.The UL Foreword is no longer located within the UL Outline of Investigation. Forinformation conc
3、erning the use and application of the requirements contained inthis Outline of Investigation, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2004 UNDERWRITERS LABORATORIES INC.NOVEMBER 19, 2004SUBJECT 2265A2No Text on This PageCONTENTSINTRODUCTION1 Scope .52 Units
4、of Measurement .63 References .64 Glossary .6CONSTRUCTION5 General 86 Flammable/Hazardous Fluids .87 Enclosures .97.1 General .97.2 Fire enclosures .98 Electrical Circuits and Components 118.1 Internal wiring .118.2 Motors .118.3 Electromechanical components .128.4 Functional insulation .128.5 Batte
5、ries .128.6 Safety controls 138.7 Circuits .139 Hazard Analysis .1310 Cartridge 14PERFORMANCE11 Test Considerations .1411.1 General .1411.2 Simulated faults and abnormal conditions for limited power and SELV circuits .1512 Determination of SELV Reliability and Limited Power .1612.1 SELV reliability
6、.1612.2 Limited power source and circuits 1612.3 Maximum VA output .1813 Material Tests 1813.1 Accelerated aging 1813.2 Fuel gas compatibility .1814 Fuel Cell Power Unit Electrical 1914.1 Abnormal operations and fault conditions 1914.2 Normal use temperature 2115 Mechanical Tests .2315.1 General .23
7、15.2 Drop test 2315.3 Vibration test 2315.4 Steady force test .2415.5 Stress relief test 2616 Environmental Tests 2616.1 Temperature cycling 2616.2 Emissions test .2716.3 Pressure test 30NOVEMBER 19, 2004 SUBJECT 2265A 317 Cartridge Mechanical Tests 3017.1 Crush test .3017.2 Drop test 3118 Cartridge
8、 Environmental Tests 3118.1 Temperature cycling test 3118.2 Altitude simulation 32MANUFACTURING AND PRODUCTION TESTS19 Pressure Test 3220 Maximum VA Output 32MARKINGS21 General 3322 Markings for the Fuel Cell Power Unit .3323 Markings for the Fuel Cartridges 34INSTRUCTIONS24 Instructions 3424.1 Gene
9、ral .3424.2 Fuel cell power units 3524.3 Fuel cartridges .37APPENDIX A Fuel Cell Power Units Intended for Extended Outdoors UseNOVEMBER 19, 2004SUBJECT 2265A4INTRODUCTION1 Scope1.1 These requirements cover hand-held or hand-transportable fuel cell power units that use disposablemethanol fuel cartrid
10、ges. These requirements also cover the disposable fuel cartridges. Theserequirements apply to power units that provide dc outputs rated 60 Vdc or less and 240 VA or less. Assuch, the internal and external circuitry are considered secondary circuits that are “SELV.”1.2 The fuel cell power units cover
11、ed by these requirements are for use in unclassified (ordinary)locations in ambient temperatures that do not exceed 60C (140F). The fuel cell power units are to beintegrated into information technology equipment on the production line by the original equipmentmanufacturer. The fuel cartridges are to
12、 be installed and replaced by the end-product user.1.3 These requirements cover fuel cell power units that are electrical power sources that includeintegrated electrical connection means, integrated wiring material leads with or without electricalconnectors, or a combination of these arrangements fo
13、r single or multiple electrical loads. Additionalelectrical connection means may be provided to affect information exchange with the end-use product asdesigned.1.4 These requirements cover disposable fuel cartridges and fuel cell power units that are not intendedfor use with common consumer electron
14、ics appliances.1.5 Federal regulatory requirements pertaining to the shipment of fuel cartridges is outside the scope ofthis Outline of Investigation.1.6 This Outline of Investigation establishes requirements for disposable fuel cartridges limited inpressure to the vapor pressure of the methanol fue
15、l.1.7 Disposable cartridges with a fuel capacity greater than 950 mL and refillable cartridges are excludedfrom this Outline of Investigation.1.8 The technologies covered by these requirements include direct methanol fuel cell stacks and fuelsidentified as methanol, or methanol and water mixtures wi
16、th or without additives.NOVEMBER 19, 2004 SUBJECT 2265A 52 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.3 References3.1 Any undated reference to a code or standard appearing in the requirements of this
17、Outline ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.4 Glossary4.1 For the purpose of these requirements, the following definitions apply.4.2 DISPOSABLE FUEL CARTRIDGE A disposable container of fuel that is not refillable.4.3 ELECTRIC SHOCK Electri
18、c shock is due to current passing through the human body. Theresulting physiological effects depend on the value and duration of the current and the path it takesthrough the body. The value of the current depends on the applied voltage, the impedance of thesource and the impedance of the body. The b
19、ody impedance depends in turn on the area of contact,moisture in the area of contact and the applied voltage and frequency. Currents of approximately half amilliampere can cause a reaction in persons in good health and may cause injury indirectly due toinvoluntary reaction. Higher currents can have
20、more direct effects, such as burn, muscle tetanization orventricular fibrillation.4.4 EXPLOSION When the cell or fuel cell power unit contents are forcibly expelled and the cell orfuel cell power unit casing is torn or split into two or more pieces.4.5 EXTENDED OUTDOOR-USE PRODUCT A product that is
21、intended for use outdoors and used inlocations where it will be exposed to weather conditions as noted in Exception No. 2 of 22.1 andevaluated in accordance with Appendix A.4.6 FIRE ENCLOSURE The outer enclosure of the fuel cell power unit that is intended to minimizethe spread of fire or flames fro
22、m within.4.7 FUEL Any mixture of methanol with or without water and/or specified additives that is used toproduce electricity in a micro fuel cell unit.4.8 FUEL CARTRIDGES, NON-PRESSURIZED A cartridge in which the fuel vapor pressure does notexceed the surrounding ambient pressure during operation.4
23、.9 FUEL CARTRIDGES, PRESSURIZED A cartridge that is sealed and is suitable for safe shippingor transport. The internal cartridge pressure will be a factor of the surrounding ambient temperature andatmospheric pressure.4.10 FUNCTIONAL INSULATION Insulation that is necessary only for the correct funct
24、ioning of theequipment. Functional insulation is located between SELV circuits and between SELV circuits andconductive parts.Note: Functional insulation does not protect against electric shock but it may reduce the likelihood ofignition and fire.NOVEMBER 19, 2004SUBJECT 2265A64.11 IMPERMISSIBLE LEAK
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT2265A2004OUTLINEOFINVESTIGATIONFORHANDHELDORHANDTRANSPORTABLEFUELCELLPOWERUNITSWITHDISPOSABLEMETHANOLFUELCARTRIDGESFORUSEINORIGINALEQUIPMENTMANUPDF

链接地址:http://www.mydoc123.com/p-1069256.html