UL SUBJECT 2055-2006 Outline of Investigation for Power Cable Assemblies (Issue 2)《电力电缆组件调查大纲 发布编号 2》.pdf
《UL SUBJECT 2055-2006 Outline of Investigation for Power Cable Assemblies (Issue 2)《电力电缆组件调查大纲 发布编号 2》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2055-2006 Outline of Investigation for Power Cable Assemblies (Issue 2)《电力电缆组件调查大纲 发布编号 2》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 27, 20061SUBJECT 2055OUTLINE OF INVESTIGATIONFORPOWER CABLE ASSEMBLIESIssue Number: 2December 27, 2006Summary of TopicsThis new issue of SU 2055 is being issued through ULs electronicpub
2、lishing system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in th
3、isStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 27, 2006SUBJECT 20552No Text on This PageUL COPYRIGHTED M
4、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 53 Undated References 5CONSTRUCTION4 Cables .55 Connectors .66 Polarization 67 Strain Relief 68 Support Device .6MARKINGS9 Label at Each Cable End 610 Terminal Identifi
5、cation 711 Identification of Mating Connectors .7DECEMBER 27, 2006 SUBJECT 2055 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover pendant and non-pendant power cable assemblies (pendant power cabl
6、eassemblies and power cable assemblies) for interconnecting or powering units of a communications orsimilar system where the assemblies are outside the unit enclosures and installed in areas accessible onlyto qualified persons. These products consist of factory-made multiple-conductor assemblies of
7、connectorsto power cables in which all of the conductors are insulated. They are for connection on the load side ofListed overcurrent devices of a-c or d-c circuits as specified in Section 240-21(a) of the National ElectricalCode, NFPA 70-1999. They are not for disconnection under load and are so ma
8、rked.1.2 Power cable assemblies are rated in volts and amperes. Their current rating is the maximum load inamperes for the cable in free air at 30C (86F), with derating of the cable ampacity as specified in Section400-5 or 318-11 of the National Electrical Code, NFPA 70-1999 where appropriate becaus
9、e of the numberof current-carrying conductors.1.3 Pendant power cable assemblies consist of Listed Type W portable power cables or Listed bus-dropcables factory-terminated at each end to Listed female connectors, wire connectors, or other means formating to male connectors, power-supply bus bars, or
10、 field-wiring terminals. Mating connectors areidentified on the assembly or in accompanying instructions. For fastening to the building structure, asupport device near the upper end of each cable keeps the weight of the cable from applying tension toany wiring terminal at the supply or load connecti
11、ons. The length of cable between the support device andthe upper termination does not exceed 6 feet or 1.83 meters. Strain relief is also provided at each end.1.4 Non-pendant power cable assemblies consist of Listed Type TC power and control tray cablesfactory-terminated at one or both ends to Liste
12、d male or female connectors, wire connectors, or otherwiring devices for mating to connectors, field-wiring terminals, other terminations, or power-supply busbars. Where one end is not terminated, the conductors are for individual termination in the field using wireconnectors Listed for the conducto
13、r material (copper or aluminum) and size and for the solid conductorsor the particular type of conductor stranding, number of strands, and size of strands used in the cableconductors. These assemblies are appropriate for use in cable trays as specified in Article 318 of theNational Electrical Code,
14、NFPA 70-1999. Where installed in an area in which the assembly is protectedfrom physical damage, no more than 7 feet or 2.1 meters of the cable is to be exposed between the cabletray and the equipment.1.5 A product that contains features, characteristics, components, materials, or systems new or dif
15、ferentfrom those covered by the requirements in this Outline of Investigation, and that involves a risk of fire,electric shock, or injury to persons shall be evaluated using the appropriate additional component andend-product requirements as determined necessary to maintain the acceptable level of s
16、afety as originallyanticipated by the intent of this Outline of Investigation. A product whose features, characteristics,components, materials, or systems conflict with specific requirements or provisions of this Outline ofInvestigation cannot be judged to comply with this Outline of Investigation.
17、Where considered appropriate,revision of requirements shall be proposed and adopted in conformance with the methods employed fordevelopment, revision, and implementation of this Outline of Investigation.DECEMBER 27, 2006SUBJECT 20554UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORD
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT20552006OUTLINEOFINVESTIGATIONFORPOWERCABLEASSEMBLIESISSUE2 电力电缆 组件 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069223.html