1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULApril 30, 20131UL 2039OUTLINE OF INVESTIGATIONFORFLEXIBLE CONNECTOR PIPING FOR FUELSIssue Number 2April 30, 2013Summary of TopicsThis new issue of UL 2039 is being issued to:1) Identify a revised
2、 effective date of July 31, 2014, as announcedin our November 6, 2012 bulletin2) Update the ATSM D5798 Fuel Specification title and revisedblend range3) Clarify general sample preparation information and worst casesample guidance4) Accept a minimum of 10 times the pressure rating as analternate comp
3、liance measure of a minimum 70% breakdownpressure, for all repeat pressure testing5) Extend the lower end of the allowable cycle rate from 6 to 4cycles/minute for the surge test to reflect expected use conditionsand test equipment specifications6) Reduce the exposure times from 180 to 120 days forco
4、mpatibility testing to reflect improved inspection regulations andpractices, for accessible fueling system products7) Clarify a minimum 20 inch length instead of 1/2 the pipe lengthis acceptable for minimum pipe lengths that exceed the fire testpan diameterThis issue becomes effective JULY 31, 2014.
5、COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 30, 2013UL 20392No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCON
6、TENTSINTRODUCTION1 Scope .52 Units of Measurement .73 Undated References 74 Glossary .7CONSTRUCTION5 General 8PERFORMANCE6 General 97 Pressure Tests 117.1 General 117.2 Leakage test 127.3 Hydrostatic test .127.4 Breakdown test .128 Vacuum Tests .138.1 General 138.2 Static vacuum test .138.3 Cyclic v
7、acuum test 139 Physical Abuse Tests 149.1 General 149.2 Drop test .149.3 Impact test .159.4 Puncture test .159.5 Fitting torque test 159.6 Pipe torque test .169.7 Tension test 169.8 Compression test 169.9 Bending test 1710 Cyclic Use Tests 1710.1 General .1710.2 Vibration test 1810.3 Surge test .181
8、0.4 Flex test 1910.5 Swivel test .1911 Short-Term Compatibility Tests .2011.1 General .2011.2 UV exposure test 2011.3 Metallic stress crack test 2111.4 Nonmetallic stress crack test 2112 Long-Term Compatibility Tests .2113 Fire Test .2414 Interstitial Communication Test .24APRIL 30, 2013 UL 2039 3UL
9、 COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMANUFACTURING AND PRODUCTION TESTS15 General 2516 Dimensional Measurements 2517 Leakage Tests .25MARKINGS18 General 25INSTRUCTIONS19 General 26Appendix A Test Fuel FormulationsA1 Representative Agg
10、ressive Combustible Test Fuel Mixtures and UL-B100 .A1A2 Representative Aggressive Flammable Test Fuels and Mixtures .A2APRIL 30, 2013UL 20394UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover prima
11、ry, secondary, and coaxial types of flexible connector pipes intendedfor short length transfer and containment of the specific liquid fuels (or vapors thereof) identified in thisOutline, at commercial (public) or fleet (private) automotive motor vehicle fueling stations.1.2 Connector pipes may be me
12、tallic, nonmetallic, or composite, but are limited to maximum 12 ft (3.65m) lengths in nominal sizes up to 4 inches (102 mm) as flexible transition components within fueldispensing and/or vapor recovery piping systems, typically intended for use in the following automotivefueling station application
13、s:a) Underground use (below surface but accessible such as within chase piping) whenconnected to underground tanks or underground pipes with expected exposures to soil, water,and soil fluids;b) Sump use (enclosed tank, transition or dispenser types) when connected to pumps, valves,monitors, or dispe
14、nsing devices with expected exposures to soil, water, soil fluids, andoccasional sunlight;c) Aboveground use (above surface but with additional physical protection) when connected toaboveground tanks or aboveground pipes with expected exposures to soil, water, soil fluids,and sunlight.1.3 Connector
15、pipe systems are intended for containment of automotive fuels and exposure to soil fluidsthat have similar chemical, physical and material compatibility properties as represented by the test liquidsin these requirements based on fuels formulated in accordance with 40 CFR Part 80, Regulation of Fuels
16、and Fuel Additives, and meeting the following ASTM Fuel Specifications and blend limitations:a) ASTM D-975, Standard Specification for Diesel Fuel Oils, with biodiesel blends up to amaximum of 5 percent (B5);b) ASTM D-7467, Standard Specification for Low Blend Biodiesel, with biodiesel blendsbetween
17、 6 to 20 percent (B6 to B20).c) ASTM D-4814, Standard Specification for Automotive Spark-Ignition Engine Fuel, gasoline oroxygenated gasoline, with limited ethanol blends up to a maximum of 10 percent (E10).d) ASTM D-5798, Standard Specification for Ethanol Fuel Blends for Flexible-Fuel AutomotiveSp
18、ark-Ignition Engines, high blend ethanol, with gasoline/ethanol mixtures in the (E51 E83)range.e) Mid Range Ethanol Blends (E11 to E50) using variable mixtures of ASTM D4814 Low BlendEthanol and ASTM D5798 High Blend EthanolAPRIL 30, 2013 UL 2039 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
19、EPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL1.4 Products covered by this outline are intended to be installed and used in accordance with:a) Flammable and Combustible Liquids Code, NFPA 30,b) Code for Motor Fuel Dispensing Facilities and Garages, NFPA 30A,c) Uniform Fire Code, NFPA 1,d) Int
20、ernational Fire Code published by the International Fire Council, ore) Other applicable federal and state regulations for piping.1.5 These products are factory manufactured and intended for on-site field assembly, inspection, andleak testing for the specified applications and use conditions by quali
21、fied persons in accordance with themanufacturers instructions and local requirements.1.6 These products are intended to be periodically inspected and maintained for continued service, ortaken out of service if necessary, by qualified persons in accordance with industry recommended practicesand/or th
22、e manufacturers instructions.1.7 These products have not been evaluated for use after natural disasters, fires or exposures tochemicals not representative of the test liquids or excessive physical damage beyond the expectedassembly, installation and uses as identified in these requirements.1.8 These
23、 products have not been evaluated for special use piping applications where exposed to heavyor continuous physical abuses, excessive mechanical stresses; or environments that are highly corrosive;or operate outside of the expected ambient use temperature range for significant times.1.9 These require
24、ments do not cover underground piping products for liquid fuels, which are found inNonmetallic Underground Piping for Flammable Liquids, UL 971 or Outline of Investigation for MetallicUnderground Piping for Flammable Liquids, Subject 971A.1.10 These requirements do not cover aboveground piping produ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT20392013OUTLINEOFINVESTIGATIONFORFLEXIBLECONNECTORPIPINGFORFUELSISSUE2 用于 燃料 柔性 接管 调查 大纲 议题

链接地址:http://www.mydoc123.com/p-1069221.html