UL SUBJECT 111-2015 UL Outline for Investigation Multioutlet Assemblies (Issue 4)《多引线组件的UL调查大纲(议题3)》.pdf
《UL SUBJECT 111-2015 UL Outline for Investigation Multioutlet Assemblies (Issue 4)《多引线组件的UL调查大纲(议题3)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 111-2015 UL Outline for Investigation Multioutlet Assemblies (Issue 4)《多引线组件的UL调查大纲(议题3)》.pdf(108页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFebruary 27, 20151UL 111Outline of Investigation for Multioutlet AssembliesIssue Number: 3February 27, 2015Summary of TopicsThis Third Issue of the Outline of Investigation for Multioutlet Assemb
2、lies,UL 111, covers the addition of Supplement SA, Modular Factory WiredFloor Mounted Multioutlet Assemblies.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and
3、all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 27, 2015UL
4、 1112No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSPART I ALL MULTIOUTLET ASSEMBLIESINTRODUCTION1 Scope .72 General 82.1 Components .82.2 Units of measurement .92.3 Undated References .93 Glossary .9CONSTRUCTION4
5、General .125 Assembly .136 Mounting 156.1 General 156.2 Surface mounted multioutlet assemblies 166.3 Suspended multioutlet assemblies .166.4 Multioutlet assembly power poles 177 Electrical and Fire Enclosures .177.1 General 177.2 Polymeric materials 177.3 Metallic materials 177.4 Protection against
6、corrosion 217.5 Covers .217.6 Partitions .217.7 Mounting or support of luminaires (light fixtures), signs and accessories .228 Electrical Construction 228.1 Protection of wiring 228.2 Grounding 238.3 Bonding 268.4 Electrical continuity 278.5 Wiring devices 278.6 Switches and controls 288.7 Splices a
7、nd connections .298.8 Spacings .308.9 Printed-wiring boards 318.10 Field wiring connections .328.11 Internal wiring 348.12 Installation of Power, Class 1, Class 2 and Class 3 circuits within the same enclosure .348.13 Multioutlet assembly device wiring 358.14 Supplementary overcurrent protectors 358
8、.15 Control circuits .368.16 Laser devices 378.17 Strain relief 379 Accessories .3710 Wiring Kits .3811 Multiple Frequency Multioutlet Assemblies .38FEBRUARY 27, 2015 UL 111 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPERFORMANCEGENERAL12
9、 General 39MECHANICAL PERFORMANCE TESTS13 Accessory Support 3914 Outlet Secureness 4015 Security of Knockout and Breakaway Tabs 4116 Mounting Hole Barriers 4117 Deflection Under Heat and Load 4218 Mold Stress 4519 Crush .4620 Cold Impact 4721 Low Temperature Handling 4822 Nonmetallic Hinge Cycling .
10、4923 Suspended Load Test .4924 Strain Relief 5024.1 Cable strain relief 5024.2 Strain relief for field wiring leads .51ELECTRICAL PERFORMANCE TESTS25 Electrical Resistance Test .5225.1 Measured on individual pieces .5225.2 Measured across joints .5226 Enclosure Fault Current Test .5327 Short Circuit
11、 Test .5428 Temperature Test .5429 Printed Wiring Board (PWB) Ground Path Test .5630 Printed Circuit Board (PWB) Conductor Overcurrent Test 5731 Spill Test 5831.1 General .5831.2 Method I (Dry use work surface, refer to 6.2.2) 5831.3 Method II (Work area directly adjacent to a lavatory, refer to 6.2
12、.2) .6032 Dielectric Voltage Withstand .6132.1 General method 6132.2 Spill test method .6233 Gaskets and Seals 6233.1 General .6233.2 Cycle test .6233.3 Tensile strength and elongation tests .6233.4 Compression test .63INSTALLATION INSTRUCTIONS AND MARKING34 Installation Instructions 6435 Markings .
13、6635.1 General .6635.2 Marking, accessories .6835.3 Marking, wiring kits .68FEBRUARY 27, 2015UL 1114UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPART II MOTOR OPERATED MULTIOUTLET ASSEMBLIESCONSTRUCTION36 Motors .6936.1 General .6936.2 Over
14、load protection .6936.3 Overload or thermal protective devices 7037 Accessibility of Uninsulated Live Parts, Film-Coated Wire and Moving Parts .70PERFORMANCE38 Starting Current Test 7439 Input Test 7440 Temperature Tests 7541 Pinch Point Force Test 78MARKING42 General 78SUPPLEMENT SA - MODULAR FACTO
15、RY WIRED FLOOR MOUNTED MULTIOUTLET ASSEMBLIESINTRODUCTIONSA1 Scope SA1SA2 Glossary SA1CONSTRUCTIONSA3 Accessible Routes .SA2SA3.1 Reduction of trip hazard SA2SA3.2 Slip resistance of floor surface materials .SA3SA4 Mounting .SA3SA5 Materials .SA4SA5.1 Modular system raceways SA4SA5.2 Modular system
16、raceway conductors SA4SA5.3 Nonmetallic electrical enclosures SA4SA5.4 Electrical insulation .SA5SA6 Wiring Devices SA5SA7 Grounding and Bonding SA6SA8 Accessibility of Parts .SA6SA9 Conductor Fill Requirements SA6SA10 Mechanical Assembly .SA7SA11 Corrosion Protection SA7SA12 Power-Supply Connection
17、s SA7SA13 Modular Mating Connectors SA7SA13.1 General .SA7SA13.2 Flammability .SA8SA13.3 Electrical properties SA8FEBRUARY 27, 2015 UL 111 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSA13.4 Thermal properties .SA9SA13.5 Modular mating con
18、nector physical .SA9SA13.6 Modular system termination SA10SA14 Receptacle Outlet Enclosures for Use with Modular Systems .SA10SA15 Outlets .SA10SA16 Gaskets and Seals SA10SA17 Receptacle Outlet Box Cover Plates .SA11PERFORMANCESA18 General SA11ELECTRICAL TESTSSA19 Electrical Resistance Test SA13SA19
19、.1 Individual pieces SA13SA19.2 Across joints .SA13SA20 Fault Current Test .SA14SA20.1 Modular system raceway and joints .SA14SA20.2 Receptacle outlet fault current test SA16SA21 Temperature Test .SA16SA22 Dielectric Voltage-Withstand Test SA18MECHANICAL TESTSSA23 Crush Resistance .SA19SA23.1 Large
20、area crush resistance SA19SA23.2 Point load crush resistance SA19SA24 Resistance To Impact SA20SA24.1 Resistance to vertical impact .SA20SA24.2 Resistance to horizontal impact .SA20SA25 Mold-Stress Test SA21SA26 User Accessible Outlet Overload Test SA22SA27 Receptacle Outlet Secureness Test SA23SA28
21、 Gaskets and Seals Tests .SA25SA29 Water Exclusion Test SA26SA30 Accessories .SA26INSTALLATION INSTRUCTIONSSA31 General SA27MARKINGSSA32 General SA28APPENDIX AStandards for ComponentsA1FEBRUARY 27, 2015UL 1116UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERM
22、ISSION FROM ULPART I ALL MULTIOUTLET ASSEMBLIESINTRODUCTION1 Scope1.1 These requirements cover Multioutlet Assemblies and factory assembled wiring kits for installation inMultioutlet Assemblies. Multioutlet Assemblies consist of a raceway, multiple outlet wiring devices thatprovide power for connect
23、ion of utilization equipment and are intended for use in dry locations, other thanhazardous (classified) in accordance with the National Electrical Code, NFPA 70. Multioutlet Assembliesare intended to be connected to permanently installed branch circuits operating at frequencies between50 400 Hz and
24、 DC (Direct Current) circuits.1.2 This outline does not cover devices that incorporate GFCI receptacles only. These devices arecovered by the Standard for Ground Fault Circuit Interrupters, UL 943.1.3 Multioutlet Assemblies may be provided with fuses or other supplementary overcurrent protection,swi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT1112015ULOUTLINEFORINVESTIGATIONMULTIOUTLETASSEMBLIESISSUE4 引线 组件 UL 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069130.html