UL SUBJECT 103A-2005 OUTLINE OF INVESTIGATION FOR MASONRY FIREPLACE ADAPTERS FOR RESIDENTIAL TYPE AND BUILDING HEATING APPLIANCE CHIMNEYS (Issue 1)《家用及建筑物供暖设备烟囱用砖石结构壁炉连接管调查大纲 发布编号 .pdf
《UL SUBJECT 103A-2005 OUTLINE OF INVESTIGATION FOR MASONRY FIREPLACE ADAPTERS FOR RESIDENTIAL TYPE AND BUILDING HEATING APPLIANCE CHIMNEYS (Issue 1)《家用及建筑物供暖设备烟囱用砖石结构壁炉连接管调查大纲 发布编号 .pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 103A-2005 OUTLINE OF INVESTIGATION FOR MASONRY FIREPLACE ADAPTERS FOR RESIDENTIAL TYPE AND BUILDING HEATING APPLIANCE CHIMNEYS (Issue 1)《家用及建筑物供暖设备烟囱用砖石结构壁炉连接管调查大纲 发布编号 .pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 26, 20051SUBJECT 103AOUTLINE OF INVESTIGATIONFORMASONRY FIREPLACE ADAPTERS FOR RESIDENTIAL TYPE ANDBUILDING HEATING APPLIANCE CHIMNEYSIssue No: 1May 26, 2005Summary of TopicsThis is the first
2、 issue of the Outline of Investigation for Masonry FireplaceAdapters for Residential Type and Building Heating Appliance Chimneys,Subject 103A.COPYRIGHT 2005 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 26,
3、 2005SUBJECT 103A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .54 Undated References 55 Glossary .5CONSTRUCTION6 Materials .67 Assembly 6PERFORMANCE8 Ge
4、neral 79 Test Installation .89.1 General .89.2 Enclosed chimney installations (residential type and building heating appliance chimney) .89.3 Unenclosed chimney installations (building heating appliance type chimney only .810 Temperature Measurement .911 Thermal Shock Test .912 Temperature Test 1000
5、F (538C) Flue Gases 913 Temperature Test 1400F (760C) Flue Gases 914 Temperature Test 1700 F (927C) Flue Gases .915 Temperature Test 2100F (1149C) Flue Gases 916 Draft Test 917 Vertical Support Test 1018 Damper Tests 1018.1 General .1018.2 Cycling test 1118.3 Opening test .11MARKING19 General 11INST
6、ALLATION AND MAINTENANCE INSTRUCTIONS20 General 12MAY 26, 2005 SUBJECT 103A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover adapters for attaching and supporting specific factory-built chimneys
7、forresidential type and building heating appliances to a masonry fireplace or a masonry chimney constructedin accordance with Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances, NFPA211, and applicable codes such as International Residential Code (IRC), International Mechani
8、cal Code(IMC) and Uniform Mechanical Code (UMC).1.2 Masonry fireplace adapters covered by these requirements comply with either a 1700F (927C)flue-gas temperature test or a 2100F (1149C) flue-gas temperature test, at the manufacturers option.1.3 Masonry fireplace adapters intended for residential in
9、stallations shall comply with section 9.2 of thisoutline of investigation and the Enclosed Chimney Installations Temperature Tests of the Standard forFactory-Built Chimneys for Residential Type and Building Heating Appliances, UL 103.1.4 Masonry fireplace adapters evaluated to these requirements are
10、 not intended for use with factory-builtfireplaces.1.5 Fireplace adapters intended for use with factory-built are to be evaluated according to therequirements of the Standard for Factory-Built Fireplaces, UL 127.1.6 Masonry fireplace adapters covered by these requirements may be provided with an int
11、egralnonregulating fireplace damper.1.7 Chimneys and chimney systems intended for use with masonry fireplace adapters covered by theserequirements are evaluated according to the Standard for Factory-Built Chimneys for Residential Typeand Building Heating Appliances, UL 103.1.8 These requirements do
12、not cover seismic or structural securement of the fireplace adapter andchimney assembly to the masonry fireplace. Refer to applicable codes for these requirements.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirements for that c
13、omponent.2.2 A component need not comply with a specific requirement that:a) Involves a feature or characteristic not needed in the application of the component in thevalue covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with i
14、ts rating established for the intended conditions ofuse.MAY 26, 2005SUBJECT 103A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such com
15、ponents are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orappr
16、oximate information.4 Undated References4.1 Any undated reference to code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this outline, the following definitions apply.5.2 FIREP
17、LACE DAMPER A plate used to stop the flow of air or the flow of flue-gas air mixturesfrom inside a fireplace to the outdoors.5.3 HEATING APPLIANCE A chimney-connected, fuel-burning device.5.4 MASONRY CHIMNEY A field constructed chimney of solid masonry units, bricks, stones, orreinforced - portland-
18、cement concrete, lined with chimney flue liners built in accordance with applicablebuilding code requirements.5.5 MASONRY FIREPLACE A field-constructed assembly constructed in accordance with theStandard for Chimneys, Fireplaces, Vents, and Solid Fuel- Burning Appliances, NFPA 211, and inaccordance
19、with the International Residential Code (IRC).5.6 NONREGULATING FIREPLACE DAMPER A fireplace damper operated by a linkage or othermechanism constructed so that it may remain in the full closed or full open position and attempts toplace the damper in any position between open and closed results in th
20、e damper moving to itsdesigned open position.MAY 26, 2005 SUBJECT 103A 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONSTRUCTION6 Materials6.1 A masonry fireplace adapter part shall comply with the “Materials” Section of the Standard forFa
21、ctory-Built Chimneys for Residential Type and Building Heating Appliances, UL 103.6.2 Fireplace damper plates, pivots, supports, and fasteners shall be constructed of materials equivalentin strength and corrosion resistance to at least No. 20 MSG (0.036 in. nominal) thickness stainless steel.7 Assem
22、bly7.1 A masonry fireplace adapter shall comply with the “Assembly” Section of the Standard forFactory-Built Chimneys for Residential Type and Building Heating Appliances, UL 103.7.2 A masonry fireplace adapter shall be completely assembled by the manufacturer at the factory.7.3 A masonry fireplace
23、adapter shall comply with the “Joints” Section of the Standard for Factory-BuiltChimneys for Residential Type and Building Heating Appliances, UL 103.7.4 A masonry fireplace adapter shall comply with the “Openings in Chimney Walls” Section of theStandard for Factory-Built Chimneys for Residential Ty
24、pe and Building Heating Appliances, UL 103.7.5 A fireplace damper shall be designed for one-handed operation without the use of tools.7.6 A tool may be provided but not relied upon for the intended operation.7.7 A fireplace damper shall have no features or obvious modifications providing for setting
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT103A2005OUTLINEOFINVESTIGATIONFORMASONRYFIREPLACEADAPTERSFORRESIDENTIALTYPEANDBUILDINGHEATINGAPPLIANCECHIMNEYSISSUE1

链接地址:http://www.mydoc123.com/p-1069125.html