UL SUBJECT 1008M-2015 UL Outline for Investigation Transfer Switch Equipment Meter Mounted (Issue 2).pdf
《UL SUBJECT 1008M-2015 UL Outline for Investigation Transfer Switch Equipment Meter Mounted (Issue 2).pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1008M-2015 UL Outline for Investigation Transfer Switch Equipment Meter Mounted (Issue 2).pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 28, 20151UL 1008MTRANSFER SWITCH EQUIPMENT, METER MOUNTEDIssue No: 2August 28, 2015Summary of TopicsThis Second Issue of Outline of Investigation for Transfer SwitchEquipment, Meter Mounte
2、d, UL 1008M, is being issued to incorporaterequirements for meter mounted transfer switches intended for use withpermanently connected generators.ULs Outlines of Investigations are copyrighted by UL. Neither a printed orelectronic copy of an Outline of Investigation should be altered in any way. All
3、 ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT
4、PERMISSION FROM ULAUGUST 28, 2015UL 1008M2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components .53 Units of Measurement 54 Undated References 5CONSTRUCTION5 General 56 Enclosure .67 Ins
5、ulating Material .68 Mounting of Parts .69 Guarding and Accessibility of Live Parts 710 Current-Carrying Parts .711 Field Wiring Terminals .712 Internal Wiring 813 Grounding and Bonding 814 Operating Mechanism 914.1 General 914.2 Location and protection of transfer control circuits 1015 Receptacles
6、1016 Inlets for Cord Connection to a Portable Generator .1117 Spacings 1117.1 General .1117.2 Spacings on printed wiring boards 12PERFORMANCE18 General 1319 Normal Operation Test 1320 Overvoltage Test .1421 Undervoltage Test 1422 Overload Test 1423 Temperature Test .1624 Endurance Test 1925 Dielectr
7、ic Voltage-Withstand Test 1926 Withstand 2027 Closing 22RATINGS28 Details .23MARKINGS29 Content 2330 Permanence of Marking .24AUGUST 28, 2015 UL 1008M 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements c
8、over automatic and non-automatic (manual) transfer switch equipment,operating at 600 V ac less, and intended for installation in a utility meter base, in ordinary locations only.1.2 These devices are intended for use in optional standby systems only, and are not intended for use inEmergency or Legal
9、ly Required Standby Systems. These devices are intended for one of the followingapplications:a) Cord connection of a portable generator to power a premise wiring system, where theneutral (grounded circuit conductor) of the generator is not bonded to ground or the generatorframe, and bonding of the n
10、eutral (grounded circuit conductor) to ground will occur within themeter base orb) Permanent connection of a stationary generator to power a premise wiring system, wherethe generator is connected as a non-seperately derived system, where the neutral (groundedcircuit conductor) of the generator is no
11、t bonded to ground or the generator frame.1.3 These devices are connected between the meter mounting equipment and the electric utility meter,on the line side of the service disconnect. As such, the installation of these devices is intended to be underthe exclusive control of the serving utility, an
12、d these are not considered under the purview of the NationalElectrical Code, NFPA 70. Generators and associated wiring connected to the generator terminals of thetransfer switch are not considered under the exclusive control of the utility, and are under the purview ofNFPA 70.1.4 An automatic transf
13、er switch as covered by these requirements is a device that automaticallytransfers a common load from a normal supply to an alternate supply in the event of failure of the normalsupply, and automatically returns the load to the normal supply when the normal supply is restored. Anautomatic transfer s
14、witch may be provided with a logic control circuit that inhibits automatic operation ofthe device from either a normal to an alternate supply, or from an alternate to a normal supply when theswitch reverts to automatic operation upon loss of power to the load.1.5 A non-automatic transfer switch as c
15、overed by these requirements is a device, operated manually bya physical action, or electrically by a remote control, for transferring a common load between a normal andalternate supply.1.6 A transfer switch may incorporate overcurrent protection for the main power circuits.1.7 These requirements on
16、ly cover transfer switches which are completely enclosed when installed in ameter base in conjunction with the electrical utility meter.1.8 Transfer switches are rated in amperes and are considered to be acceptable for total system transfer,which includes control of motors, electric-heating loads, a
17、nd transformer loads.AUGUST 28, 2015UL 1008M4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline of Investigation shallcomply with the requirements for th
18、at component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in
19、 accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified
20、limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the require
21、ments of this outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 General5.1 Transfer switches shall employ materials throughout which are acceptable for the particular use, andshall be made and finished with the degree of uniformity and grade of wor
22、kmanship practicable in awell-equipped factory.AUGUST 28, 2015 UL 1008M 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6 Enclosure6.1 A transfer switch shall be provided with an enclosure, which complies with the requirements of theStandard
23、for Meter Sockets, UL 414.6.2 An external operating means such as those for a disconnect, a pilot device, or a resetting operation mounted on or through an enclosure shall withstand the tests specified for the enclosure.6.3 Marking and instructions on the exterior of the device shall be permanent. S
24、ee 30.1.6.4 Meter mounted transfer switches which are intended for outdoor use in wet locations shall complywith the requirements for Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosures, as detailed in the Enclosure Sectionof the Standard for Transfer Switch Equipment, UL 1008. Transfer switches intended for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT1008M2015ULOUTLINEFORINVESTIGATIONTRANSFERSWITCHEQUIPMENTMETERMOUNTEDISSUE2PDF

链接地址:http://www.mydoc123.com/p-1069122.html