UL 998 CRD-2014 UL Standard for Safety Humidifiers - Section Paragraph Reference New Supplement SA Subject Smart Enabled Humidi ers (Edition 5 April 25 2011)《加湿器的UL安全标准 节 段落参考 新补充.pdf
《UL 998 CRD-2014 UL Standard for Safety Humidifiers - Section Paragraph Reference New Supplement SA Subject Smart Enabled Humidi ers (Edition 5 April 25 2011)《加湿器的UL安全标准 节 段落参考 新补充.pdf》由会员分享,可在线阅读,更多相关《UL 998 CRD-2014 UL Standard for Safety Humidifiers - Section Paragraph Reference New Supplement SA Subject Smart Enabled Humidi ers (Edition 5 April 25 2011)《加湿器的UL安全标准 节 段落参考 新补充.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): AHIVStandard Number: UL 998Standard Title: Standard for HumidifiersEdition Date: April 25, 2011Edition Number: 5Section / Paragraph Reference: New Supplement
3、 SASubject: Smart Enabled HumidifiersDECISION:(New Supplement)SUPPLEMENT SA SMART ENABLED HUMIDIFIERSSA1 ScopeSA1.1 These requirements apply to humidifiers intended to receive and respond to communication signalsor data relating to power billing rate or demand response or communication signals from
4、a remote userinterface, such as a smart phone or computer.SA1.2 Appliances covered by SA1.1 are commonly identified as smart appliances or smart enabledand are intended to interact with the Smart Grid, as described by the US Energy Independence andSecurity Act of 2007, or other communication network
5、s not identified as Smart Grid.SA1.3 These requirements contemplate smart enabled technology as described by the U. S. EnergyIndependence and Security Act of 2007 that is integral with the appliance or incorporated as an accessory(wired to the appliance or wireless with a corresponding appliance rec
6、eiver) on the appliance or in thesame occupancy as the appliance.SA1.4 These requirements supplement those specified in this Standard.SA1.5 These requirements encompass accessory devices to which multiple appliances may communicateand be smart enabled by providing direction for investigation of such
7、 devices in addition to therequirements of standards generally applicable to those devices.SA1.6 These requirements do not address the integrity of any output signal or data to the network devicesor interoperability with other devices.SA1.7 These requirements do not apply to communication network de
8、vices that control appliances viageneral purpose power ON/OFF, building wiring devices, panelboard mounted devices, or utility meters.SA1.8 These requirements apply to wired or wireless remote commands from the user by way of:a) Controls only capable of communicating within line-of-sight of the appl
9、iance (e.g. infraredwireless);UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULb) Short range controls only capable of communicating within proximity or same occupancy ofthe appliance but not necessarily within line-of-sight (e.g. short-wave ra
10、dio frequency); orc) Long range telecommunication controls without proximity limits (e.g. WiFi, local areanetworks, wide area networks).SA1.9 These requirements include, but are not limited to, the following remote initiated functions:a) Monitored status (e.g. ON/OFF, timer, etc.);b) Humidity ON;c)
11、Setting adjustment decrease;d) Setting adjustment increase;e) Cancel timer humidity ON;f) Extended delay timer humidity ON;g) Cancel timer humidity OFF;h) Extended delay timer humidity OFF; andi) Humidity OFF.CONSTRUCTIONSA2 GeneralSA2.1 ControlsSA2.1.1 Controls that respond to external communicatio
12、n signals or data shall comply with theconstruction and performance requirements of the Standard for Automatic Controls for Household andSimilar Use, Part 1: General Requirements, UL 60730-1, and tested as an operating (regulating) controlutilizing the parameters specified in Table SA1. If the contr
13、ol also incorporates protective (limiting)functions, these control functions shall be evaluated to the requirements for protective controls.SA2.1.2 With respect to SA2.1.1, the requirement is not applicable to controls located in low voltagecircuits where the maximum power available does not exceed
14、15 W. This does not exempt the controlfrom investigation for compliance with SA3.1.SA2.1.3 With respect to SA2.1.1, compliance with the Standard for Solid-State Controls for Appliances,UL 244A, taking into account criteria comparable to that specified in Table SA1 is considered to fulfill thisrequir
15、ement.SA2.1.4 With respect to SA2.1.1, a communication device that is not integral with the appliance control(e.g. on a separate printed wiring board) and complying with the Standard for Information TechnologyEquipment - Safety - Part 1: General Requirements, UL 60950-1, is considered to fulfill thi
16、s requirement.STANDARD NUMBER: UL 998 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSA2.1.5 For the purposes of application of the Standard for Automatic Controls for Household and SimilarUse, Part 1: General Requirements, UL 60730-1, EMC
17、 emissions testing of H23 is not applicable tocontrols, which are integral with the appliance or incorporated as an accessory (wired or wireless) on theappliance or in the same occupancy as the appliance.Table SA1Operating Control ParametersInformation Operating Control RequirementOperating Ambient
18、Determined via Normal Temperature Test, Section 57Endurance Testing for power switching devices See 36.2 and 38.4Overvoltage Category Overvoltage Category IIPollution Degree See Note 1)Note 1) - The internal microenvironment of the enclosure shall be considered Pollution Degree 2 (that is, an enviro
19、nment thatnormally has only nonconductive pollution, or a temporary conductivity resulting from condensation) as specified in the Standardfor the Standard for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment, UL 840.Pollution Degree 1 is permitted at a cre
20、epage distance by encapsulation or hermetic sealing. For printed wiring boards, coatingsmay be used that satisfy the performance criteria specified in UL 840.SA2.1.6 With respect to the Endurance Testing indicated in Table SA1, the control shall remainoperational and comply with the Electric Strengt
21、h Test of the Standard for Automatic Controls forHousehold and Similar Use, Part 1: General Requirements, UL 60730-1, Section 13.2.SA2.1.7 When the control enclosure forms part of the overall appliance enclosure, the enclosure materialshall have a flammability rating in accordance with 5.2.SA2.2 Sep
22、aration of CircuitsSA2.2.1 The separation of communication circuits from power and control circuits shall be evaluated forrisk of electric shock in accordance with Section 29.SA2.2.2 With respect to SA2.2.1, compliance with the separation of circuit requirements of the Standardfor:a) Automatic Contr
23、ols for Household and Similar Use, Part 1: General Requirements, UL60730-1; orb) Information Technology Equipment - Safety - Part 1: General Requirements, UL 60950-1 isconsidered to fulfill this requirement.SA2.3 Communication and Display DevicesSA2.3.1 An external communication or display device, s
24、uch as a router or monitor, provided as anaccessory for use with the appliance, shall comply with the Standard for Information TechnologyEquipment - Safety - Part 1: General Requirements, UL 60950-1.SA2.3.2 The power supply cord of an external communication or display device shall comply with thisSt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL998CRD2014ULSTANDARDFORSAFETYHUMIDIFIERSSECTIONPARAGRAPHREFERENCENEWSUPPLEMENTSASUBJECTSMARTENABLEDHUMIDIERSEDITION5APRIL252011

链接地址:http://www.mydoc123.com/p-1069117.html