UL 982 CRD-2016 UL Standard for Safety Motor-Operated Household Food Preparing Machines - Section Paragraph Reference 26 10 Table 6 2 Subject Magnetic Interlock (Edition 7 June 10.pdf
《UL 982 CRD-2016 UL Standard for Safety Motor-Operated Household Food Preparing Machines - Section Paragraph Reference 26 10 Table 6 2 Subject Magnetic Interlock (Edition 7 June 10.pdf》由会员分享,可在线阅读,更多相关《UL 982 CRD-2016 UL Standard for Safety Motor-Operated Household Food Preparing Machines - Section Paragraph Reference 26 10 Table 6 2 Subject Magnetic Interlock (Edition 7 June 10.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL LLC CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(s); however, it is curre
2、ntly not part of the UL Standard(s) referencedbelow.Product Category (CCN): IPWZStandard Number: UL 982Standard Title: Standard for Motor-Operated Household Food Preparing MachinesEdition Date: June 10, 2015Edition Number: 7Section / Paragraph Reference: 26.10, Table 6.2Subject: Magnetic InterlockDE
3、CISION:Table 6.2Protective control parametersProtective control parameter Minimum specificationFMEA Conduct a failure-mode and effect analysis (FMEA) to identifycomponent failures which may result in a risk of electric shock,fire or injury and confirming protective function continues tooperate as in
4、tended. (1)Operating Ambient Determined via the Normal Temperature Test on the appliance(Section 34)Endurance Testing Except for interlocks, as indicated in 6.18.3.2, 6000 cycles ofoperation required for controls starting or stopping the motorOvervoltage Category Overvoltage Category IIPollution Deg
5、ree Pollution Degree 2Enclosure Flammability As specified in Section 61 for portable appliances or Section62 for other appliancesConducted Disturbances Test Level 3Radiated Electromagnetic Fields Test Level 3Fast Transient Bursts Test Level 3 applied for 2 minutes in each polaritySurge Immunity Inst
6、allation Class 2Electrostatic Discharge Test Level 3Thermal Cycling Temperature range: 10.0 2C to the Operating AmbientSoftware Class Software Class B (See 6.5.3.3)Notes: (1) For a magnetic interlock reed switch, the short-circuit failure mode of the contacts is excluded due to the InterlockSystem E
7、ndurance Test of 55.2.26.10.1 For a magnetic interlock, common magnets are considered readily available with respect to26.10(c). A magnetic interlock is considered to comply with 26.10(c) if common magnets are not able todefeat the interlock by a construction with:a) An actuating magnet with a highe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL982CRD2016ULSTANDARDFORSAFETYMOTOROPERATEDHOUSEHOLDFOODPREPARINGMACHINESSECTIONPARAGRAPHREFERENCE2610TABLE62SUBJECTMAGNETICINTERLOCKEDITION7JUNE10PDF

链接地址:http://www.mydoc123.com/p-1069106.html