UL 962A CRD-2016 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 12 1 4 Subject Power Supply Cord Length (Edition 4 February 22 2016).pdf
《UL 962A CRD-2016 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 12 1 4 Subject Power Supply Cord Length (Edition 4 February 22 2016).pdf》由会员分享,可在线阅读,更多相关《UL 962A CRD-2016 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 12 1 4 Subject Power Supply Cord Length (Edition 4 February 22 2016).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): IYNCStandard Number: UL 962AStandard Title: Standard for Furniture Power Distribution UnitsEdition Date: September 29, 2014Edition Number: 3Section / Paragra
3、ph Reference: Sections 1 (Scope); 5 (Glossary); Sections 12.1.10,12.3 (Construction) and 31 (Performance)Subject: Class 2 LeadDECISION:1 Scope1.1 These requirements cover indoor use cord and plug connected furniture power distribution units(FPDU) rated 250 V AC or less and 20 Amperes or less. An FPD
4、U may include an integral Class 2 powersupply with an integral lead and/or connector(s) output. FPDUs are for fixed mounting to furnishings asa power supply connection for cord and plug connected electrical utilization equipment in accordance withthe National Electric Code, NFPA 70.5 Glossary5.2.1 C
5、LASS 2 LEAD - Consists of a factory-made, power-limited cable with a connector at one end. Theother end is secured within the housing or enclosure of the FPDU. The connector is intended forconnection to the Class 2 separable interface.5.2.2 CLASS 2 SEPARABLE INTERFACE A separable component containin
6、g Class 2 low-voltageconnector(s) only (such as Universal Serial Bus (USB) connectors).5.5 FURNITURE POWER DISTRIBUTION UNIT (FPDU) m) Provided with an integral Class 2 lead and mating Class 2 separable interface, or an integralpower supply with one or more Class 2 output connector(s).12.1.10 Class
7、2 Lead12.1.11 A Class 2 lead may be one of the following types:a) Type CL2 cable in accordance with the Standard for Power-Limited Circuit Cables, UL 13b) An appliance wiring material with a maximum length of 10 feet (3.5 m), minimum of 26 AWG,rated minimum VW-1 flammability and minimum 300 V, in ac
8、cordance with the Standard forAppliance Wiring Material, UL 758.12.1.12 One end of a Class 2 lead shall be either molded-on or permanently attached to the FPDUhousing or enclosure.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL12.1.13 The oth
9、er end of a Class 2 lead shall terminate in a connector capable of being inserted into themating connector of the Class 2 separable interface.12.1.14 Permanently attached can be achieved by crimping, welding, riveting, or equivalent, to render theconnector non-rewireable.12.3 Strain Relief12.3.1 Str
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL962ACRD2016ULSTANDARDFORSAFETYFURNITUREPOWERDISTRIBUTIONUNITSSECTIONPARAGRAPHREFERENCE1214SUBJECTPOWERSUPPLYCORDLENGTHEDITION4FEBRUARY222016PDF

链接地址:http://www.mydoc123.com/p-1069082.html