UL 962A CRD-2015 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 5 6A and 13 5 Subject GFCI Protection in lieu of compliance with the Spill.pdf
《UL 962A CRD-2015 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 5 6A and 13 5 Subject GFCI Protection in lieu of compliance with the Spill.pdf》由会员分享,可在线阅读,更多相关《UL 962A CRD-2015 UL Standard for Safety Furniture Power Distribution Units - Section Paragraph Reference 5 6A and 13 5 Subject GFCI Protection in lieu of compliance with the Spill.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): IYNC, IYNC2Standard Number: UL 962AStandard Title: Standard for Furniture Power Distribution UnitsEdition Date: September 29, 2014Edition Number: 3Section /
3、Paragraph Reference: 5.6A and 13.5Subject: GFCI Protection in lieu of compliance with the Spill TestDECISION:5 Glossary5.6A PORTABLE CLASS A GFCI - A plug-in type ground-fault circuit interrupter provided with male bladesor with a power-supply cord with an attachment plug. Portable GFCIs are constru
4、cted so that when anysingle supply conductor, including the neutral conductor, is opened protection to the user is maintained.Class A GFCIs trip when the current to ground has a value in the range of 4 through 6 mA.13 Receptacles13.5 A FPDU intended to be mounted on or inside a desk or similar furni
5、shing surface shall be coveredor otherwise protected from spillage while not in use and shall comply with the Spill Test, Section 37.Exception No 1: When the intended use of the FPDU is for it to be mounted above the furnishing surfaceand oriented such that spilled liquid on the furnishing surface c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL962ACRD2015ULSTANDARDFORSAFETYFURNITUREPOWERDISTRIBUTIONUNITSSECTIONPARAGRAPHREFERENCE56AAND135SUBJECTGFCIPROTECTIONINLIEUOFCOMPLIANCEWITHTHESPILLPDF

链接地址:http://www.mydoc123.com/p-1069081.html