UL 864 CRD-2015 UL Standard for Control Units and Accessories for Fire Alarm Systems - Section Paragraph Reference See Individual Decisions Subject Revision to Permit Electronic M .pdf
《UL 864 CRD-2015 UL Standard for Control Units and Accessories for Fire Alarm Systems - Section Paragraph Reference See Individual Decisions Subject Revision to Permit Electronic M .pdf》由会员分享,可在线阅读,更多相关《UL 864 CRD-2015 UL Standard for Control Units and Accessories for Fire Alarm Systems - Section Paragraph Reference See Individual Decisions Subject Revision to Permit Electronic M .pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): UOJZStandard Number: UL 864Standard Title: Standard for Control Units and Accessories for Fire Alarm SystemsEdition Date: September 30, 2003Edition Number: 9
3、Section / Paragraph Reference: See Individual DecisionsSubject: Revision to Permit Electronic Media for Installation Wiring Diagram.DECISION:90.1.1 The installation wiring diagram referenced in 90.1 and containing the information required in 90.2 90.12 shall be made available by one or more of the f
4、ollowing means:a) Marking attached to the product;b) Separate printed instructions;c) Electronic instructions within the basic product software; andd) Electronic media such as CD-ROM, thumb drive, website, etc. or equivalent.90.1.2 When the installation wiring diagram is included as described in 90.
5、1.1 (b), (c), and/or (d), theinstallation wiring diagram shall be referenced in the product marking by:a) Name of trademark of manufacturer;b) Drawing number and/or the equivalent identification; andc) Issue date, revision level, and/or release date.RATIONALE FOR DECISION:The National Fire Alarm and
6、 Signaling Code expanded the requirements for documentation in Chapter 7of NFPA 72-2013. Clause 7.2.1 (6) includes the manufacturers published instructions as part of theminimum required documentation and 7.5.3 (1) includes the owners manual and manufacturerspublished instructions covering all syste
7、m equipment as part of the completion documentation to bedelivered to the owner. Section 7.7 addresses record retention and specifically 7.7.1.4 stipulatesdocuments regarding system design and function to be included as required documents to be maintainedfor the life of the system and that the syste
8、m documents to be housed in the documentation cabinetrequired by section 7.7.2. Further, clause 7.7.2.2 indicates all record documentation shall be stored in thedocumentation cabinet.Inspection, Testing and Maintenance (Chapter 14) also covers records, specifically including “operationand maintenanc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL864CRD2015ULSTANDARDFORCONTROLUNITSANDACCESSORIESFORFIREALARMSYSTEMSSECTIONPARAGRAPHREFERENCESEEINDIVIDUALDECISIONSSUBJECTREVISIONTOPERMITELECTRONICMPDF

链接地址:http://www.mydoc123.com/p-1068996.html