UL 83A-2016 UL Standard for Safety Flouropolymer Insulated Wire (First Edition).pdf
《UL 83A-2016 UL Standard for Safety Flouropolymer Insulated Wire (First Edition).pdf》由会员分享,可在线阅读,更多相关《UL 83A-2016 UL Standard for Safety Flouropolymer Insulated Wire (First Edition).pdf(47页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 83A Flouropolymer Insulated Wire STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTH
2、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Flouropolymer Insulated Wire, UL 83A First Edition, Dated February 1, 2016 Summary of Topics This is the First Edition of ANSI/UL 83A. The new requirements are substantially in accordance with Propo
3、sal(s) on this subject dated November 20, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Sta
4、ndard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, los
5、t savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard
6、, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation i
7、ntroduced while purchaser is storing an electronic Standard on the purchasers computer system. FEBRUARY 1, 2016 UL 83A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2016 UL 83A tr2 No Text on This PageUL COPYRIGHTED MATERIAL
8、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2016 1 UL 83A Standard for Flouropolymer Insulated Wire First Edition February 1, 2016 This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 83A as an Amer
9、ican National Standard (ANSI) occurred on February 1, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal
10、 Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Stand
11、ards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 83A-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 1, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 2 No Text on This P
12、ageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS 1 Scope .4 2 General .4 2.1 Units of measure .4 2.2 Reference publications 4 2.3 Summary of requirements .5 3 Denitions .5 4 Construction 6 4.1 Conductors 6 4.2 Insulation 9 4.3 Ass
13、emblies that include thermoplastic-insulated single conductors .11 4.4 Braids 11 5 Test requirements 11 5.1 General 11 5.2 Conductor resistance 11 5.3 Short-term insulation resistance at elevated temperature in water .12 5.4 Long-term insulation resistance in water 12 5.5 Capacitance and relative pe
14、rmittivity of wet rated ( W type) wires 12 5.6 Flexibility at room temperature after aging 13 5.7 Cold bend and cold impact .13 5.8 Deformation 13 5.9 Flame and smoke .14 5.10 Weather resistance (optional) 17 5.11 Oil resistance (optional) .17 5.12 Gasoline and oil resistance (optional) .17 5.13 Dur
15、ability of ink printing .18 5.14 Color coating 18 5.15 Long-term aging of insulation 18 5.16 A-C spark test .18 5.17 Dielectric voltage-withstand in water 19 5.18 Insulation resistance in water at 15C .19 5.19 Electrical continuity .19 6 Marking .19 6.1 Marking on product 19 6.2 Marking on package .
16、22 6.3 Month and year of manufacture .22 TABLES .22 APPENDIX A (Informative) Summary of Requirements APPENDIX B (Informative) Metric Sizes APPENDIX C (Informative) Evaluation of Materials Having Characteristics Differing from Those in Table 12 FEBRUARY 1, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 3
17、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1 Scope 1.1 This Standard species the requirements for 600 V, single-conductor, ouropolymer-insulated wires and cables in accordance with NFPA 70, National Electrical Code (NEC). Note: See Appe
18、ndix A for the complete list of wire types covered by this Standard. 1.2 Products for which this Standard provides requirements might have applications not described in the electrical code listed in 1.1. 2 General 2.1 Units of measure 2.1.1 Values stated without parentheses are the requirement. Valu
19、es in parentheses are explanatory or approximate information. 2.2 Reference publications 2.2.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. UL Standards UL 1685 Vertical-Tr
20、ay Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables UL 2556 Wire and Cable Test Methods ASTM (American Society for Testing and Materials) Standards B3-13, Standard Specication for Soft or Annealed Copper Wire B8-11, Standard Specication for Concentric-Lay-Stranded Copp
21、er Conductors, Hard, Medium-Hard, or Soft B33-10(2014), Standard Specication for Tinned Soft or Annealed Copper Wire for Electrical Purposes B160-10(2014), Standard Specication for Nickel Rod and Bar B172-10(2015), Standard Specication for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Me
22、mbers, for Electrical Conductors B173-10(2015), Standard Specication for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors FEBRUARY 1, 2016 FLOUROPOLYMER INSULATED WIRE - UL 83A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRI
23、BUTION WITHOUT PERMISSION FROM UL B174-10(2015), Standard Specication for Bunch-Stranded Copper Conductors for Electrical Conductors B355-11, Standard Specication for Nickel-Coated Soft or Annealed Copper Wire IEC (International Electrotechnical Commission) Standards 60228 (2004-11), Conductors of i
24、nsulated cables NFPA (National Fire Protection Association) Publication NFPA 70, National Electrical Code (NEC) 2.3 Summary of requirements 2.3.1 As a guide to users of this Standard, a summary of requirements is provided in Appendix A. 3 Denitions 3.1 The following denitions apply in this Standard:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL83A2016ULSTANDARDFORSAFETYFLOUROPOLYMERINSULATEDWIREFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068972.html