《UL 83 CRD-2014 UL Standard for Safety Thermoplastic-Insulated Wires and Cables - Section Paragraph Reference 4 1 7 3 Subject Joint in Class B Stranded 8 AWG (Edition 15 March 28 2.pdf》由会员分享,可在线阅读,更多相关《UL 83 CRD-2014 UL Standard for Safety Thermoplastic-Insulated Wires and Cables - Section Paragraph Reference 4 1 7 3 Subject Joint in Class B Stranded 8 AWG (Edition 15 March 28 2.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ZLGRStandard Number: UL 83Standard Title: Standard for Thermoplastic-Insulated Wires and CablesEdition Date: March 28, 2014Edition Number: 15Section / Paragr
3、aph Reference: 4.1.7.3Subject: Joint in Class B Stranded 8 AWGDECISION:4.1.7 Joints4.1.7.1 A joint in a solid conductor or in one of the individual wires of a stranded conductor shall neitherincrease the diameter nor materially decrease the strength of the conductor or the individual wire. Notmore t
4、han one of the wires in a stranded conductor of 19 wires or less, nor more than one of the wiresin any given layer in a stranded conductor of more than 19 wires, shall be joined in any 0.3 m (1 ft) ofconductor.4.1.7.2 In a rope-lay-stranded conductor, which consists of a central core surrounded by o
5、ne or morelayers of stranded members (primary groups), each member shall be considered equivalent to a solidwire, and as such, shall be spliced as a unit. These joints shall not be any closer together than 2 laylengths.4.1.7.3 A joint shall be allowed in a Class B stranded 2.08 mm2(14 AWG), 3.31 mm2
6、(12 AWG), or 5.26mm2(10 AWG), or 8.37 mm2(8 AWG) insulated copper conductor intended to be used in amultiple-conductor cable, with an overall covering. The joint (butt splice) shall be made by machinebrazing or welding the entire conductor such that the resulting solid section of the stranded conduc
7、tor isno longer than 13 mm (0.50 inch). In addition, the joint shall not increase the diameter of the conductor,there shall be no sharp points, and the distance between joints in a single conductor shall not averageless than 1000 m (3280 ft) in any finished length of that single insulated conductor.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL83CRD2014ULSTANDARDFORSAFETYTHERMOPLASTICINSULATEDWIRESANDCABLESSECTIONPARAGRAPHREFERENCE4173SUBJECTJOINTINCLASSBSTRANDED8AWGEDITION15MARCH282PDF

链接地址:http://www.mydoc123.com/p-1068967.html