UL 8-2016 UL Standard for Safety Water Based Agent Fire Extinguishers (Seventh Edition).pdf
《UL 8-2016 UL Standard for Safety Water Based Agent Fire Extinguishers (Seventh Edition).pdf》由会员分享,可在线阅读,更多相关《UL 8-2016 UL Standard for Safety Water Based Agent Fire Extinguishers (Seventh Edition).pdf(53页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 8 Water Based Agent Fire Extinguishers STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NO
2、T AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Water Based Agent Fire Extinguishers, UL 8 Seventh Edition, Dated November 25, 2016 Summary of Topics These revisions to ANSI/UL 8 include: 1. Siphon tubes The revised requirements are substan
3、tially in accordance with Proposal(s) on this subject dated June 24, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission
4、of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, i
5、ncluding loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the p
6、rice paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting fr
7、om any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. NOVEMBER 25, 2016 UL 8 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 25, 2016 UL 8 tr2 No Text on This Pa
8、geUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Prepared by: ULC Standards CAN/ULC-S554 Third Edition Underwriters Laboratories Inc. ANSI/UL 8 Seventh Edition Water Based Agent Fire Extinguishers November 25, 2016 This harmonized standard
9、has been jointly revised on November 25, 2016 to reect updates to the standard. For this purpose, UL and ULC Standards have updated the Title Page and Preface dated November 25, 2016. ANSI/UL 8-2016 Approved byUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PE
10、RMISSION FROM UL Commitment for Amendments This Standard is issued jointly by Underwriters Laboratories Inc. (UL) and ULC Standards. Amendments to this Standard will be made only after processing according to the Standards writing procedures by UL and ULC Standards. UL and ULC Standards are separate
11、 and independent entities and each is solely responsible for its operations and business activities. The UL trade names and trademarks depicted in this document are the sole property of Underwriters Laboratories Inc. The ULC trade names and trademarks depicted in this document are the sole property
12、of ULC Standards. ISSN 0317-526X Copyright 2016 ULC Standards All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior permission of the publisher. In Canada, written comments are to be sent to the ULC Standards
13、, 400 - 171 Nepean Street, Ottawa, Ontario K2P 0B4. Proposals should be submitted on a Standards Revision Request Form available from ULC Standards. Copyright 2016 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard shoul
14、d be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through November 25, 2016. The most recent desig
15、nation of ANSI/UL 8 as an American National Standard (ANSI) occurred on November 25, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to
16、 UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .6 INTRODUCTION 1 Scope .7 2 U
17、nits of Measurement .7 3 Reference Publications 7 4 Components 7 5 Glossary .7 CONSTRUCTION 6 General 9 7 Cylinders .10 8 Joints .10 9 Caps, Valves, Closures, and Pressure Relief 11 10 Gaskets and “O” rings .11 11 Gas Cartridges, Cylinders, and Regulators .11 12 Pressure Gauges and Indicators 12 13
18、Puncturing Mechanisms .13 14 Tamper Indicators and Locking Devices .13 15 Hose 14 16 Couplings 14 17 Nozzles and Discharge Valves .14 18 Siphon Tubes 15 19 Strainers .15 20 Handles and Mounting Devices .15 21 Hose Retainers Wheeled Extinguishers 16 22 Running Gear Wheeled Extinguishers .16 23 Expell
19、ant Gases 16 24 Antioverll tubes 16 25 Extinguishing Agent .16 PERFORMANCE 26 General 17 27 Fire Tests 17 28 Tamper Indicator and Locking Device Test .17 28.1 Tamper Indicator .17 28.2 Locking Device and Tamper Indicator .17 29 Handle and Mounting Device Test 18 30 Operation Test .18 31 Discharge Du
20、ration Test .18 32 Rate of Flow Test .19 33 Discharge Range Test .19 34 Intermittent Discharge Test 19 35 Operating Temperature Limits Test .20 36 Temperature Cycling Test .20 37 30-Day Elevated Temperature Test .20 38 High-Temperature Exposure Test .20 NOVEMBER 25, 2016 CAN/ULC-S554 ANSI/UL 8 3UL C
21、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 39 Abnormal Operation Test 20 40 Hydrostatic Pressure Test .21 40.1 Cylinders 21 40.2 Discharge valves, caps, and closures .22 40.3 Hose assemblies .22 40.4 Gas cartridges .23 40.5 Test method .23
22、41 Vibration Test 23 41.1 General .23 41.2 Mounting of test sample .24 41.3 Test orientation 24 41.4 Variable frequency test .24 41.5 Endurance test .25 42 Roadability and Rough Usage Tests 25 42.1 Roadability 25 42.2 Rough usage 26 42.3 Rough usage operation .26 43 Siphon Tube Attachment Test - Pol
23、ymeric Materials 26 43.1 General .26 43.2 Press-t type siphon tube assemblies .27 43.3 Threaded siphon tube assemblies 27 44 Aging Tests Polymeric Materials 27 44.1 General .27 44.2 Exposure to extinguishing agent test .28 44.3 Light and water test 29 45 Elastomeric Parts Test 29 46 Salt Spray Corro
24、sion Test .30 47 10-Day Moist Ammonia Air Stress Cracking Test .30 48 Agent Exposure Test 31 48.1 Disposable (nonrechargeable) re extinguishers .31 48.2 Rechargeable (rellable) re extinguishers 31 49 Servicing Tests .32 50 One-Year Time Leakage Test 32 51 Calibration Test Gauges and Indicators 32 52
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL82016ULSTANDARDFORSAFETYWATERBASEDAGENTFIREEXTINGUISHERSSEVENTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068946.html