UL 795-2016 UL Standard for Safety Commercial-Industrial Gas Heating Equipment (Eighth Edition).pdf
《UL 795-2016 UL Standard for Safety Commercial-Industrial Gas Heating Equipment (Eighth Edition).pdf》由会员分享,可在线阅读,更多相关《UL 795-2016 UL Standard for Safety Commercial-Industrial Gas Heating Equipment (Eighth Edition).pdf(133页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 795 Commercial-Industrial Gas Heating Equipment STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MA
2、TERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Commercial-Industrial Gas Heating Equipment, UL 795 Eighth Edition, Dated December 2, 2016 Summary of Topics This new edition of UL 795 includes direct vent revisions and removal of t
3、est number references. The revisions are substantially in accordance with Proposal(s) on this subject dated September 2, 2016. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopyin
4、g, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incid
5、ental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event
6、shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgmen
7、t (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. DECEMBER 2, 2016 UL 795 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
8、FROM UL DECEMBER 2, 2016 UL 795 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 2, 2016 1 UL 795 Standard for Commercial-Industrial Gas Heating Equipment First Edition November, 1952 Second Edition October, 1
9、964 Third Edition April, 1973 Fourth Edition June, 1994 Fifth Edition July, 1999 Sixth Edition October, 2006 Seventh Edition April, 2011 Eighth Edition December 2, 2016 This UL Standard for Safety consists of the Eighth Edition. The Department of Defense (DoD) has adopted UL 795 on January 27, 1992.
10、 The publication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards De
11、velopment System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property
12、 of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 2, 2016 COMMERCIAL-INDUSTRIAL GAS HEATING EQUIPMENT - UL 795 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTH
13、ER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .6 2 Glossary .6 3 Units of Measurement 14 4 Undated References .14 5 Components 14 CONSTRUCTION MECHANICAL 6 General.14 7 Corrosion Protection .15 8 General Components and Devices .16 CONSTRUCTION ELECTRICAL 9
14、General.16 10 Servicing and Adjustment 17 11 Electrical Enclosures 17 12 Field Wiring Connections 26 13 Internal Wiring30 14 Separation of Circuits .34 15 Mounting of Components 35 16 Motors and Motor Overcurrent or Overload Protection.36 17 Overcurrent Protection of High-Voltage Control-Circuit Con
15、ductors40 17.1 General .40 17.2 Tapped high-voltage control circuits 40 17.3 Overcurrent-protective devices .41 18 Overcurrent Protection of Transformers42 18.1 High-voltage transformers .42 18.2 Thermal protection .42 18.3 Low-voltage transformers43 18.4 Overcurrent protective devices .43 19 Switch
16、es and Controllers 44 20 Capacitors .45 21 Electrical Insulating Material46 22 Spacings High-Voltage Circuits .46 23 Spacings Low-Voltage Circuits47 24 Accessibility of Uninsulated Live Parts.48 25 Bonding For Grounding50 CONSTRUCTION BURNER ASSEMBLIES 26 General53 27 Combination Gas-Oil Burner Asse
17、mblies 54 CONSTRUCTION BOILERS, FURNACES AND HEATERS 28 General55 29 Accessibility 56 DECEMBER 2, 2016 COMMERCIAL-INDUSTRIAL GAS HEATING EQUIPMENT - UL 795 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 30Baffles.56 31 Limit Controls 56 31
18、.1 General .56 31.2 Liquid level limit controls boilers 57 31.3 Pressure limit controls boilers 58 31.4 Temperature limit controls boilers.59 31.5 Temperature limit controls warm air furnaces and heaters .60 32 Installation of External Controls and Fittings on Boilers 60 33 Flue Dampers, Draft Regul
19、ators, and Draft Hoods 61 34 Bleeds and Vents .62 35 Bases .63 36 Heating Surfaces and Combustion Chambers 63 37 Radiation Shields .64 38 Materials in Air Handling Compartments .64 39 Casings .65 40 Fuel Lines and Components .66 41 Flue Collars 66 42 Air Filters 66 PERFORMANCE 43 General66 44 Test I
20、nstallations68 44.1 Floor-mounted devices 68 44.2 Suspended furnaces 68 44.3 Unit heaters .72 44.4 Test ducts for furnaces .73 45 Test Methods 73 45.1 Firing conditions73 45.2 Temperature measurements .74 46 Burner Assembly Tests 78 46.1 Combustion test78 46.2 Combustion air failure test.80 46.3 Und
21、ervoltage test 81 46.4 Power interruption test 82 46.5 Pilot supervision test83 46.6 Ignition, gas-electric high tension test .83 46.7 Ignition, gas-electric hot-wire Undervoltage test 84 46.8 Ignition, gas-electric hot-wire Igniter endurance test.85 46.9 Ignition, gas-electric hot-wire Temperature
22、test .85 46.10 Ignition, multiple burner test 86 46.11 Delayed ignition test .86 47 Operation Tests 87 47.1 Device limit control cutout test .87 47.2 Continuity of operation for furnaces and heaters test .88 47.3 Air ow of horizontal furnaces test88 48 Temperature Tests89 48.1 General .89 48.2 Conti
23、nuous operation test .93 48.3 Blocked inlet of furnaces and heaters test .93 48.4 Fan failure of furnaces and heaters test .93 48.5 Blocked outlet of furnaces and duct-connected heaters test .94 49 Low Water Cutoff of Boilers Test .94 DECEMBER 2, 2016 COMMERCIAL-INDUSTRIAL GAS HEATING EQUIPMENT - UL
24、 795 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 50 Short-Circuit Test .95 51 Overload Test, High-Voltage Transformers.97 52 Burnout Test, High-Voltage Transformers 98 53 Dielectric Voltage-Withstand Test .99 54 Draft Hood Equipped Devi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7952016ULSTANDARDFORSAFETYCOMMERCIALINDUSTRIALGASHEATINGEQUIPMENTEIGHTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068934.html