UL 733-1993 UL Standard for Safety Oil-Fired Air Heaters and Direct-Fired Heaters (Fourth Edition Reprint with Revisions Through and Including October 09 2013)《燃油空气加热器和直接燃烧加热器》.pdf
《UL 733-1993 UL Standard for Safety Oil-Fired Air Heaters and Direct-Fired Heaters (Fourth Edition Reprint with Revisions Through and Including October 09 2013)《燃油空气加热器和直接燃烧加热器》.pdf》由会员分享,可在线阅读,更多相关《UL 733-1993 UL Standard for Safety Oil-Fired Air Heaters and Direct-Fired Heaters (Fourth Edition Reprint with Revisions Through and Including October 09 2013)《燃油空气加热器和直接燃烧加热器》.pdf(102页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 733 Oil-Fired Air Heaters and Direct-Fired HeatersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHOR
2、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Oil-Fired Air Heaters and Direct-Fired Heaters, UL 733 Fourth Edition, Dated August 25, 1993 Summary of Topics This revision to UL 733 is being issued to remove the reference to the withdrawal date of
3、 UL 873 and to address universal upkeep of UL Standards for Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes
4、in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system
5、, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability o
6、r tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL re
7、presentative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harm
8、less from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effe
9、ct, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Stand
10、ard, and are preceded by a SUPERSEDED REQUIREMENTS notice. OCTOBER 9, 2013 UL 733 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 9, 2013 UL 733 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTI
11、ON OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 25, 1993 (Title Page Reprinted: October 9, 2013) 1 UL 733 Standard for Oil-Fired Air Heaters and Direct-Fired Heaters First Edition August, 1955 Second Edition May, 1973 Third Edition July, 1975 Fourth Edition August 25, 1993 This UL Standard for
12、Safety consists of the Fourth Edition including revisions through October 9, 2013. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS)
13、 at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 U
14、NDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 13, 2005 OIL-FIRED AIR HEATERS AND DIRECT-FIRED HEATERS - UL 733 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR D
15、ISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 3 Units of Measurement .6 3A Undated References .6 4 Glossary .6 5 Instructions .9 CONSTRUCTION 6 Assembly .10 7 Accessibility for Servicing .11 8 Disposal of Combustion Products 11 9 Casing 12 10 Radiation Shields o
16、r Liners and Materials in Air Handling Compartments 12 11 Air Filter .13 12 Integral Oil Tanks .13 13 Combustion Chamber .14 14 Radiator .14 15 Heating Surface Joints 14 16 Baffles.15 17 Flue Collar .15 18 Damper and Draft Regulator .16 19 Ducts 16 20 Controls .16 20.1 Application 16 20.2 Limit cont
17、rol 16A 20.3 Primary safety control .16A 21 Field Wiring .16B 21.1 General 16B 21.2 Leads and terminals 18 22 Internal Wiring 19 22.1 General .19 22.2 Methods 20 22.3 Short circuit protection 23 23 Separation of Circuits .23 24 Bonding for Grounding 25 ELECTRICAL COMPONENTS 25 General 28 26 Mounting
18、 of Electrical Components .29 27 Electrical Enclosures 29 27.1 General .29 27.2 Doors and covers 34 27.3 Field wiring system connection .35 28 Motors and Motor Overload Protection 36 29 Switches and Controllers 41 30 Capacitors .41 DECEMBER 13, 2005 OIL-FIRED AIR HEATERS AND DIRECT-FIRED HEATERS - U
19、L 733 2AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 31 Insulating Material 42 SPACINGS 32 High-Voltage Circuits 42 33 Low-Voltage Circuits 44 PROTECTION OF USERS AND SERVICE PERSONNEL 34 General 44 PERFORMANCE 35 General 47 36 Test Insta
20、llation .48 37 Instrumentation 48A 37.1 Draft 48A 37.2 Fuel input 48B 37.3 Power measurement 48B 37.4 Speed measurement 48B 37.5 Static pressure .51 37.6 Temperature measurement 51 38 Initial Test Conditions .53 38.1 General .53 38.2 Heater equipped with mechanical atomizing burner .54 38.3 Heater e
21、quipped with vaporizing burner .54 39 Combustion Test Burner and Heater 55 40 Operation Tests 55 41 Limit Control Cutout Test 55 42 Continuity of Operation Test .56 43 Temperature Tests 56 44 Continuous Operation Temperature Test 60 45 Blocked Inlet Test .61 46 Fan Failure Test 61 47 Stalled Fan Mot
22、or Test 62 48 Blocked Outlet Test .62 49 Maximum Wall Temperature Test .62 50 Short Circuit Test .63 51 Dielectric Withstand Test 66 52 Leakage Current Test .66 MANUFACTURING AND PRODUCTION TESTS 53 General 69 54 Production Line Dielectric Withstand Test 70 55 Production Line Grounding Continuity Te
23、st .70 MARKING 56 General 71 DECEMBER 13, 2005 OIL-FIRED AIR HEATERS AND DIRECT-FIRED HEATERS - UL 733 2BUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONSTRUCTION OUTDOOR USE EQUIPMENT 57 General 73 58 Enclosure 73 58.1 General .73 58.2 C
24、orrosion protection 74 59 Wiring .76 PERFORMANCE OUTDOOR USE EQUIPMENT 60 Rain Test 76 61 Chromic Acid Dropping Test .80 62 Gaskets .81 MARKING OUTDOOR USE EQUIPMENT 63 General 83 APPENDIX A Standards for Component.A1 DECEMBER 13, 2005 OIL-FIRED AIR HEATERS AND DIRECT-FIRED HEATERS - UL 733 3UL COPY
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7331993ULSTANDARDFORSAFETYOILFIREDAIRHEATERSANDDIRECTFIREDHEATERSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGOCTOBER092013

链接地址:http://www.mydoc123.com/p-1068861.html