UL 730-2003 UL Standard for Safety Oil-Fired Wall Furnaces (Fifth Edition Reprint with Revisions Through and Including November 22 2016)《燃油壁炉》.pdf
《UL 730-2003 UL Standard for Safety Oil-Fired Wall Furnaces (Fifth Edition Reprint with Revisions Through and Including November 22 2016)《燃油壁炉》.pdf》由会员分享,可在线阅读,更多相关《UL 730-2003 UL Standard for Safety Oil-Fired Wall Furnaces (Fifth Edition Reprint with Revisions Through and Including November 22 2016)《燃油壁炉》.pdf(100页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 730 Oil-Fired Wall FurnacesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPROD
2、UCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Oil-Fired Wall Furnaces, UL 730 Fifth Edition, Dated August 29, 2003 Summary of Topics This revision to UL 730 is being issued to remove the reference to the withdrawal date of UL 873 and to address universal upkeep of UL S
3、tandards for Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line
4、 in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, elec
5、tronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be
6、 liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibilit
7、y of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liabil
8、ity, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tabl
9、es, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREME
10、NTS notice. OCTOBER 9, 2013 UL 730 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 9, 2013 UL 730 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL A
11、UGUST 29, 2003 (Title Page Reprinted: October 9, 2013) 1 UL 730 Standard for Oil-Fired Wall Furnaces First Edition August, 1955 Second Edition September, 1974 Third Edition June, 1987 Fourth Edition December, 1994 Fifth Edition August 29, 2003 This ANSI/UL Standard for Safety consists of the Fifth E
12、dition including revisions through October 9, 2013. The most recent designation of ANSI/UL 730 as a Reaffirmed American National Standard (ANS) occurred on August 22, 2012. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Com
13、ments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor elec
14、tronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. UL/ANSI 730-2008 (R2012)UL COPYRIGHTED MATERIAL NOT AUTH
15、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 1, 2008 OIL-FIRED WALL FURNACES - UL 730 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 General 7 3
16、Glossary .7 3A Undated References 11 4 Components 11 CONSTRUCTION MECHANICAL 5 Assembly .12 6 Servicing 14 6.1 General 14 6.2 Moving parts 14 7 Disposal of Combustion Products 15 8 Casing 15 9 Radiation Shields 16 10 Materials in Air Handling Compartment 16 11 Air Filter .17 12 Combustion Chamber .1
17、7 13 Radiator .17 14 Heating Surface Joints 17 15 Baffles.18 16 Flue Collar .19 17 Damper and Draft Regulator .19 CONSTRUCTION ELECTRICAL 18 Controls .19 18.1 Application 19 18.2 Limit control .20 18.3 Primary safety control .20 19 Field Wiring 20 19.1 General .20 19.2 Leads and terminals 21 20 Inte
18、rnal Wiring 23 20.1 General .23 20.2 Methods 24 20.3 Short circuit protection 27 21 Separation of Circuits .27 22 Bonding for Grounding 28 23 Servicing and Adjustment 32 24 Electrical Components .32 25 Mounting of Electrical Components .33 26 Electrical Enclosures 33 26.1 General .33 26.2 Doors and
19、covers 37 27 Motors and Motor Overcurrent (Overload) Protection 38 28 Switches and Controllers 42 OCTOBER 1, 2008 OIL-FIRED WALL FURNACES - UL 730 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 29 Capacitors .43 30 Insulating Material 43 3
20、1 Spacings High Voltage Circuits .44 32 Spacings Low-Voltage Circuits 45 33 Accessibility of Uninsulated Live Parts, Film-Coated Wire, and Moving Parts .46 PERFORMANCE 34 General 52 35 Test Installation Built-In Style Furnaces 52 35.1 Enclosure .52 35.2 Venting .53 36 Test Installation Extended Styl
21、e Furnaces 54 36.1 Enclosure .54 36.2 Chimney connector .57 37 Instrumentation .61 37.1 Draft 61 37.2 Fuel input .61 37.3 Power measurement 61 37.4 Speed measurement .61 37.5 Temperature measurement 61 38 Initial Test Conditions .67 38.1 General .67 38.2 Furnace equipped with mechanical atomizing bu
22、rner .68 38.3 Furnace equipped with vaporizing burner 68 39 Combustion Test Burner and Furnace .69 40 Operation Tests 69 41 Limit Control Cutout Test 69 42 Continuity of Operation Test .70 43 Temperature Tests 70 43.1 General .70 44 Continuous Operation Temperatures 74 45 Blocked Register Test .75 4
23、6 Blocked Inlet Test .76 47 Fan Failure Test 77 48 Stalled Fan Motor Test 77 49 Seepage and Burnoff Test .78 50 Short Circuit Test .78 51 Dielectric Voltage Withstand Test .80 52 Flammability Test .81 MANUFACTURING AND PRODUCTION TESTS 53 General 82 MARKING 54 General 83 INSTRUCTIONS 55 Operating an
24、d Installation Instructions .85 AUGUST 29, 2003 OIL-FIRED WALL FURNACES - UL 730 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APPENDIX A Standards for ComponentsA1 AUGUST 29, 2003 OIL-FIRED WALL FURNACES - UL 730 5UL COPYRIGHTED MATERIAL
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7302003ULSTANDARDFORSAFETYOILFIREDWALLFURNACESFIFTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGNOVEMBER222016

链接地址:http://www.mydoc123.com/p-1068855.html