UL 726-1995 UL Standard for Safety Oil-Fired Boiler Assemblies (Seventh Edition Reprint with Revisions Through and Including October 09 2013)《燃油锅炉组合装置》.pdf
《UL 726-1995 UL Standard for Safety Oil-Fired Boiler Assemblies (Seventh Edition Reprint with Revisions Through and Including October 09 2013)《燃油锅炉组合装置》.pdf》由会员分享,可在线阅读,更多相关《UL 726-1995 UL Standard for Safety Oil-Fired Boiler Assemblies (Seventh Edition Reprint with Revisions Through and Including October 09 2013)《燃油锅炉组合装置》.pdf(144页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 726 Oil-Fired Boiler AssembliesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE
2、PRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Oil-Fired Boiler Assemblies, UL 726 Seventh Edition, Dated November 30, 1995 Summary of Topics This revision to UL 726 is being issued to remove the reference to the withdrawal date of UL 873 and to address universal up
3、keep of UL Standards for Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a v
4、ertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any
5、 means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no even
6、t will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of th
7、e possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, exp
8、ense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, se
9、ctions, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSED
10、ED REQUIREMENTS notice. OCTOBER 9, 2013 UL 726 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 9, 2013 UL 726 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSI
11、ON FROM UL NOVEMBER 30, 1995 (Title Page Reprinted: October 9, 2013) 1 UL 726 Standard for Oil-Fired Boiler Assemblies First Edition June, 1955 Second Edition November, 1963 Third Edition June, 1973 Fourth Edition May, 1974 Fifth Edition October, 1975 Sixth Edition September, 1990 Seventh Edition No
12、vember 30, 1995 This UL Standard for Safety consists of the Seventh edition including revisions through October 9, 2013. The Department of Defense (DoD) has adopted UL 726 on January 27, 1992. The publication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Co
13、mments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor ele
14、ctronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRO
15、DUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 6, 2011 OIL-FIRED BOILER ASSEMBLIES - UL 726 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 3 Glossary .5 3A Undated
16、 References .8 4 Components 8 CONSTRUCTION 5 Assembly .8A 6 Accessibility for Servicing .8B 6A Air-Intake Terminal .8C 6B Vent-Air Intake Assemblies .9 7 Casing 10 8 Radiation Shields or Liners 10 9 Combustion Chamber 11 10 Baffles.11 11 Flue collar .13 12 Damper and Draft Regulator .13 13 Controls
17、.13 13.1 Application 13 13.2 Limit controls 14 13.3 Primary safety control .14A 13.4 Liquid level limit controls 17 13.5 Pressure limit controls 18 13.6 Temperature limit controls .18 13.7 Purge and combustion air monitoring controls .19 13.8 Safety shut-off valves .20 14 Installation of External Co
18、ntrols and Fittings 20 15 Field Wiring .20A 15.1 General 20A 15.2 Leads and Terminals .23 16 Internal Wiring 24 16.1 General .24 16.2 Short-circuit protection 28 17 Separation of Circuits .28 18 Bonding for Grounding 30 ELECTRICAL COMPONENTS 19 General Components and Devices 32B 20 Mounting of Elect
19、rical Components .33 21 Electrical Enclosures 33 21.1 General .33 21.2 Accessibility of uninsulated live parts and lm-coated wire .37 21.3 Boilers having an input in excess of 3 gph (11.4 L/h) .37 21.4 Boilers having an input of 3 gph (11.4 L/h) or Less .40 21.5 Doors and covers .42A 21.6 Field wiri
20、ng system connection .44 APRIL 6, 2011 OIL-FIRED BOILER ASSEMBLIES - UL 726 2AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 22 Motors and Motor Overload Protection 44 23 Overcurrent Protection of High-Voltage Control-Circuit Conductors 48A
21、 23.1 General 48A 23.2 Direct-connected high-voltage control circuit 48A 23.3 Tapped high-voltage control circuits .48A 23.4 Overcurrent-protective devices 48B 24 Overcurrent Protection of Transformers 50 24.1 High-voltage transformers .50 24.2 Low-voltage transformers 51 25 Switches and Controllers
22、 52 26 Capacitors .53 27 Insulating Material 54 SPACINGS 28 High-Voltage Circuits 54 29 Low-Voltage Circuits 55 PROTECTION OF USERS AND SERVICE PERSONNEL 30 General 55 PERFORMANCE 31 General 58 32 Test Installation for Standard Clearances 60 32.1 Enclosure .60 32.2 Chimney connector .62 33 Test Inst
23、allation for Alcove or Closet 64 33.1 Enclosure .64 33.2 Chimney connector .66 34 Instrumentation .68 34.1 Draft 68 34.2 Fuel input .68 34.3 Power measurement 68 34.4 Speed measurement .68 34.5 Temperature measurement 68 35 Initial Test Conditions 70B 36 Combustion Test Burner and Boiler 70B 37 Oper
24、ation Tests 71 38 Limit Control Cutout Test 72 39 Temperature Tests 72 39A Low Water Cutoff of Boilers Test 76 40 Continuous Operation Test .77 41 Short-Circuit Test .77 42 Overload Test, High-Voltage Transformers .79 43 Burnout Test, High-Voltage Transformers 79 43A Direct Vent System Leakage Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL7261995ULSTANDARDFORSAFETYOILFIREDBOILERASSEMBLIESSEVENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGOCTOBER092013

链接地址:http://www.mydoc123.com/p-1068848.html