UL 710A-2015 UL Standard for Safety Rooftop Grease and Oil Collection and Containment Systems (First Edition).pdf
《UL 710A-2015 UL Standard for Safety Rooftop Grease and Oil Collection and Containment Systems (First Edition).pdf》由会员分享,可在线阅读,更多相关《UL 710A-2015 UL Standard for Safety Rooftop Grease and Oil Collection and Containment Systems (First Edition).pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 710A Rooftop Grease and Oil Collection and Containment SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIA
2、L NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Rooftop Grease and Oil Collection and Containment Systems, UL 710A First Edition, Dated July 10, 2015 Summary of Topics This First Edition of UL 710A covers Rooftop Grease and Oil Collecti
3、on and Containment Systems. The new requirements are substantially in accordance with Proposal(s) on this subject dated July 11, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical pho
4、tocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any specia
5、l, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In n
6、o event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or
7、 judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or othe
8、r elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JULY 10, 2
9、015 UL 710A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 10, 2015 UL 710A tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 10, 2015 1 UL 710A S
10、tandard for Rooftop Grease and Oil Collection and Containment Systems First Edition July 10, 2015 This UL Standard for Safety consists of the First Edition. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposa
11、l Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Stan
12、dards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 10, 2015 UL 710A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
13、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement .4 4 Undated References 5 CONSTRUCTION 5 General 5 PERFORMANCE 6 Fire Exposure Tests .5 6.1 Preparation of samples 5 6.2 Flaming brand test 6 6.3 Flaming grease test .6
14、 6.4 Fire exposure test 6 7 Grease Containment Tests .7 7.1 Rain test (Dry) .7 7.2 Rain test (Oil soaked) .7 8 Mechanical Abuse Tests Impact Tests .7 MARKINGS 9 General 7 INSTRUCTIONS 10 General .8 APPENDIX A Standards for ComponentsA1 JULY 10, 2015 UL 710A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FO
15、R FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover rooftop grease and oil collection and containment systems for use on roof coverings or roof systems achieving Class A, B, and C when tested in accordance with Standard for Standard Tes
16、t Methods for Fire Tests of Roof Covering Materials, UL 790. 1.2 The rooftop grease and oil collection and containment systems covered by these requirements are intended solely for use outdoors as collection and containment systems. The collection and containment systems are not intended for indoor
17、household use, nor are they intended for permanent attachment to the mounting surface of the roong system. 1.3 These systems are intended to be installed in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96, the International Mechanica
18、l Code (IMC) and/or the Uniform Mechanical Code (UMC). 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products cover
19、ed by this standard. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shal
20、l be used in accordance with its rating established for the intended conditions of use. 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. JULY 10, 2015 UL 710A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FO
21、R FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4 Undated References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. CONSTRUCTION 5 General 5.1 The enclo
22、sure of a collection and containment system shall be formed and assembled such that it has the strength and rigidity necessary to resist the abuses likely to be encountered during its intended service. The degree of resistance inherent in the system shall preclude total or partial loosening or displ
23、acement of parts, and other serious defects, which alone or in combination constitute a risk of re, explosion, or injury to persons. 5.2 Among the factors taken into consideration if an enclosure is being judged for acceptability are its: a) Mechanical strength; b) Resistance to impact; c) Moisture-
24、absorption properties; d) Flammability; e) Resistance to corrosion; and f) Resistance to distortion at temperatures to which the enclosure may be subjected under conditions of intended or abnormal use. PERFORMANCE 6 Fire Exposure Tests 6.1 Preparation of samples 6.1.1 The wooden deck for the re expo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL710A2015ULSTANDARDFORSAFETYROOFTOPGREASEANDOILCOLLECTIONANDCONTAINMENTSYSTEMSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068837.html