1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 698A Industrial Control Panels Relating to Hazardous (Classied) Locations STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSIO
2、N FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Industrial Control Panels Relating to Hazardous (Classied) Locations, UL 698A Fourth Edition, Dated August 21, 2018 Summary of Topics This new edition of ANS
3、I/UL 698A is being issued to include the following changes in requirements: Revisions to 1.2 and 1.3 to clarify what is and what is not covered by these requirements. Revisions to Section 4 to clarify existing denitions and to add new denitions. Revisions to Section 5 to clarify that it contains Gen
4、eral industrial panel requirements for panels relating to hazardous locations. Revisions to Section 6 to clarify applicable standards (UL 60079-0, UL 60079-11 and UL 120202). Revisions to 6.3 to clarify that the power to the barriers can be suitably limited by means of either an isolating transforme
5、r within the panel, or by means of the rated input to the panel. Revisions to 6.4 to correct the reference. Revisions to Section 7 to clarify the requirements for the selection of apparatus for connection to the intrinsically safe outputs of the panel, either in the eld or at the panel manufacturers
6、 facility. Revisions to Section 8 to clarify the applicable wiring and wiring terminal requirements in addition to UL 508A. Revisions to Section 9 to clarify the general requirements for separation of circuits. Revisions to 9.2 to harmonize the separation by distance requirements with the comparable
7、 requirements of UL 913 and UL 60079-11. Revisions to 9.3 to harmonize the separation by partitions requirements with the comparable requirements of UL 913 and UL 60079-11. Revisions to Section 11 to harmonize the mechanical test with the comparable requirements of UL 913 and UL 60079-11. Revisions
8、to Section 12 to clarify the application of internal markings and that an internal transformer relied upon to provide the required Um to the barrier is a component whose substitutions may impair intrinsic safety. Revisions to Section 13 to clarify the application of external markings. Revisions to S
9、ection 14 and 15 to clarify the documentation required for each panel with specic clarication regarding the required content of the panel control drawing. AUGUST 21, 2018 UL 698A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Clarication
10、 of other miscellaneous requirements and editorial corrections. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated May 25, 2018. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in an
11、y form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpos
12、e. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been
13、advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against
14、any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. AUGUST 21, 2018 UL 698A tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR F
15、URTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 21, 2018 1 UL 698A Standard for Industrial Control Panels Relating to Hazardous (Classied) Locations First Edition April, 1999 Second Edition May, 2008 Third Edition September, 2012 Fourth Edition August 21, 2018 This ANSI/UL Stan
16、dard for Safety consists of the Fourth Edition. The most recent designation of ANSI/UL 698A as an American National Standard (ANSI) occurred on August 21, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any
17、 part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be al
18、tered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 698A-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTI
19、ON WITHOUT PERMISSION FROM UL AUGUST 21, 2018 UL 698A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Undated References 5 3 Units of Measurement .5 4 Glossary .5 5 General 7 CONSTRUCT
20、ION 6 Barriers 7 7 Selection of Apparatus for Connection to Intrinsically Safe Outputs .8 7.1 General .8 7.2 Suitability of simple apparatus to be determined in the eld8 7.3 Suitability of intrinsically safe apparatus to be determined in the eld .9 7.4 Suitability of simple apparatus determined at t
21、he panel manufacturers facility .9 7.5 Intrinsically safe apparatus selected at the panel manufacturers facility 11 8 Additional Wiring and Wiring Terminal Requirements .12 8.1 General 12 8.2 Additional eld wiring terminal requirements 13 9 Separation of Circuits 13 9.1 General 13 9.2 Separation by
22、distance .13 9.3 Separation by partitions 16 9.4 Combination of separation by partitions and separation by distance .18 10 Barrier Ground Terminal .20 PERFORMANCE 11 Mechanical Tests .20 MARKINGS 12 Internal Markings .20 13 External Markings.20 PANEL DOCUMENTATION 14 General21 15 Panel Control Drawi
23、ng 21 AUGUST 21, 2018 UL 698A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover industrial control panels intended for general industrial installation and use in unclassied locations with intr
24、insically safe circuit extensions into the following hazardous (classied) locations in accordance with the National Electrical Code (NEC), NFPA 70: a) Class I, Division 1; b) Class I, Zone 0 and Zone 1 AEx; c) Class II, Division 1; d) Class III, Division 1; and e) Zone 20 and Zone 21 AEx. 1.2 The in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL698A2018ULSTANDARDFORSAFETYINDUSTRIALCONTROLPANELSRELATINGTOHAZARDOUSCLASSIFIEDLOCATIONSFOURTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068826.html