UL 698A-2012 UL Standard for Safety Industrial Control Panels Relating to Hazardous (Classified) Locations (Third Edition Reprint with revisions through and including January 5 201.pdf
《UL 698A-2012 UL Standard for Safety Industrial Control Panels Relating to Hazardous (Classified) Locations (Third Edition Reprint with revisions through and including January 5 201.pdf》由会员分享,可在线阅读,更多相关《UL 698A-2012 UL Standard for Safety Industrial Control Panels Relating to Hazardous (Classified) Locations (Third Edition Reprint with revisions through and including January 5 201.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 698A Industrial Control Panels Relating to Hazardous (Classied) LocationsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGH
2、TED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Industrial Control Panels Relating to Hazardous (Classied) Locations, UL 698A Third Edition, Dated September 14, 2012 Summary of Topics This New Edition of ANSI/UL 698A is being
3、 issued to incorporate the following changes in requirements: Revisions to the Scope and Applicable Requirements of UL 698A to Include AEx Class I, Zones 0 and 1, and AEx Zones 20 and 21 References and Clarication of Nonmetallic Partition Thickness Requirements in Paragraph 9.3.1 These requirements
4、are substantially in accordance with Proposal(s) on this subject dated May 25, 2012 and July 27, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwi
5、se without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, in
6、direct or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for
7、any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable
8、attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard havin
9、g future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. SEPTEMBER 14, 2012 UL 698A tr1UL COPYRIGHT
10、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 14, 2012 UL 698A tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL September 14, 2012 1 UL 698A Standard for Indus
11、trial Control Panels Relating to Hazardous (Classied) Locations First Edition April, 1999 Second Edition May, 2008 Third Edition September 14, 2012 This ANSI/UL Standard for Safety consists of the Third Edition. The most recent designation of ANSI/UL 698A as an American National Standard occurred on
12、 September 14, 2012. The ANSI approval for this standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Req
13、uest in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards
14、 shall remain the sole and exclusive property of UL. COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC. ANSI/UL 698A-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 14, 2012 UL 698A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT
15、AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Undated References 5 3 Units of Measurement .5 4 Glossary .5 5 Application of Requirements 6 CONSTRUCTION 6 Barriers 6 7 External Equipment .6 8 Spacings .8 9 Separation of Circuits 9 9.
16、1 General .9 9.2 Separation by distance 9 9.3 Separation by partitions 11 10 Ground Terminal 13 PERFORMANCE 11 Mechanical Tests .13 MARKINGS 12 Internal Markings .13 13 External Markings .13 INSTALLATION INSTRUCTIONS 14 General 14 15 Panel Control Drawing 14 SEPTEMBER 14, 2012 UL 698A 3UL COPYRIGHTE
17、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover industrial control panels intended for general industrial use and installation in unclassied locations with intrinsically safe circuit extensions into the f
18、ollowing hazardous (classied) locations in accordance with the National Electrical Code (NEC), NFPA 70: a) Class I, Division 1; b) Class I, Zone 0 and Zone 1; c) Class II, Division 1; d) Class III, Division 1; and e) Zone 20 and Zone 21. 1.2 The industrial control panels covered by these requirement
19、s are not intended for metal working machine tools, plastic injection molding, power press controls, ame safety supervision of combustible fuel type equipment, or elevator controls. 1.3 These requirements do not cover electrostatic devices, circuits or systems, gas or vapor analysis equipment or oth
20、er equipment having a process line brought into an enclosure. 1.4 The industrial control panels covered by these requirements are assemblies consisting of components such as motor controllers, overload relays, fused disconnect switches, and/or circuit breakers and related control devices such as pus
21、hbutton stations, selector switches, pilot lights, timers, switches, control relays and the like with associated wiring terminals. In all cases, the enclosure is provided as part of the assembly. 1.5 These requirements cover equipment for use under the following atmospheric conditions: a) An ambient
22、 temperature not exceeding 40C (104F); b) An oxygen concentration not greater than 21 percent by volume; and c) A nominal barometric pressure of one atmosphere. SEPTEMBER 14, 2012 UL 698A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Un
23、dated References 2.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses ar
24、e explanatory or approximate information. 4 Glossary 4.1 For the purpose of this Standard, the following denitions apply. 4.2 BARRIER The device that provides the intrinsically safe circuit. 4.3 BARRIER CONTROL DRAWING A drawing or other document provided by the manufacturer of each intrinsically sa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL698A2012ULSTANDARDFORSAFETYINDUSTRIALCONTROLPANELSRELATINGTOHAZARDOUSCLASSIFIEDLOCATIONSTHIRDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY5201PDF

链接地址:http://www.mydoc123.com/p-1068825.html